# Start of file 61015_artiq_log.txt # First point: 61015.524162 2025-12-06T12:34:47.625000+00:00 # Last point: 61015.797700 2025-12-06T19:08:41.300000+00:00 # Num rows: 20 # File updated: 2025-12-07T01:11:11.119776 # Columns: MJD DATE RID PROGRAM MESSAGE 61015.524162326 2025-12-06T12:34:47.625000+00:00 110653 StateMachineSupervisor Ion Dark 61015.524168391 2025-12-06T12:34:48.149000+00:00 110653 StateMachineSupervisor Recover Ion 61015.524177546 2025-12-06T12:34:48.940000+00:00 110705 switchBeam Beam: ABC 61015.524209005 2025-12-06T12:34:51.658000+00:00 110708 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 61015.524308079 2025-12-06T12:35:00.218000+00:00 110709 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 25.0. 61015.524326945 2025-12-06T12:35:01.848000+00:00 110711 switchBeam Beam: B 61015.524348947 2025-12-06T12:35:03.749000+00:00 110712 MeasureFluorescenceLevels Bright : 46.7 +- 6.9, Dark : 0.1 +- 0.2, Threshold: int( ceil( 1.5 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 61015.524360694 2025-12-06T12:35:04.764000+00:00 110653 StateMachineSupervisor Ion Bright, Start Clockrun 61015.524393090 2025-12-06T12:35:07.563000+00:00 110715 switchBeam Beam: B 61015.524402951 2025-12-06T12:35:08.415000+00:00 110716 Lock_to_C1234 t_probe [us] = 137000, n_shots = 1, g1 = 0.2, T_drift_s = 600.0, N_drift = 942, pmt.thr = 22, pmt.thr2 = 10, T_p0avg_s = 900.0, N_p0avg = 471, (C1, C2, C4) att [dB] = (15.00, 15.87, 15.65), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8058, LCminus [V] = 3.1331, 61015.797459144 2025-12-06T19:08:20.470000+00:00 110653 StateMachineSupervisor Ion Dark 61015.797465220 2025-12-06T19:08:20.995000+00:00 110653 StateMachineSupervisor Recover Ion 61015.797474525 2025-12-06T19:08:21.799000+00:00 110717 switchBeam Beam: ABC 61015.797505718 2025-12-06T19:08:24.494000+00:00 110720 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 61015.797605162 2025-12-06T19:08:33.086000+00:00 110721 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 25.0. 61015.797623889 2025-12-06T19:08:34.704000+00:00 110723 switchBeam Beam: B 61015.797645799 2025-12-06T19:08:36.597000+00:00 110724 MeasureFluorescenceLevels Bright : 45.5 +- 6.1, Dark : 0.1 +- 0.4, Threshold: int( ceil( 1.7 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 61015.797657697 2025-12-06T19:08:37.625000+00:00 110653 StateMachineSupervisor Ion Bright, Start Clockrun 61015.797690463 2025-12-06T19:08:40.456000+00:00 110727 switchBeam Beam: B 61015.797700231 2025-12-06T19:08:41.300000+00:00 110728 Lock_to_C1234 t_probe [us] = 137000, n_shots = 1, g1 = 0.2, T_drift_s = 600.0, N_drift = 942, pmt.thr = 22, pmt.thr2 = 10, T_p0avg_s = 900.0, N_p0avg = 471, (C1, C2, C4) att [dB] = (15.00, 15.87, 15.65), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8058, LCminus [V] = 3.1331, # End of file 61015_artiq_log.txt