# Start of file 61011_artiq_log.txt # First point: 61011.705367 2025-12-02T16:55:43.729000+00:00 # Last point: 61011.810883 2025-12-02T19:27:40.298000+00:00 # Num rows: 40 # File updated: 2025-12-03T01:11:12.824378 # Columns: MJD DATE RID PROGRAM MESSAGE 61011.705367234 2025-12-02T16:55:43.729000+00:00 110370 SetAtt att_RCDAT : 0.0 dB 61011.728105278 2025-12-02T17:28:28.296000+00:00 110377 SetAtt att_RCDAT : 16.0 dB 61011.728506794 2025-12-02T17:29:02.987000+00:00 110378 SetLockFreqs Linecenter [MHz AOM]: 75.506282, abs(B) [uT]: 44.986990000, EQS C1, C2, C4 [Hz]: 0.0, 0.0, 0.0 61011.728528333 2025-12-02T17:29:04.848000+00:00 110379 StateMachineSupervisor Start Clockrun 61011.728551493 2025-12-02T17:29:06.849000+00:00 110381 switchBeam Beam: B 61011.728561343 2025-12-02T17:29:07.700000+00:00 110382 Lock_to_C1234 t_probe [us] = 13700, n_shots = 1, g1 = 0.2, T_drift_s = 600.0, N_drift = 4200, pmt.thr = 22, pmt.thr2 = 10, T_p0avg_s = 900.0, N_p0avg = 2100, (C1, C2, C4) att [dB] = (15.00, 15.87, 15.65), att_RCDAT [dB] = 16.00, LCplus [V] = 1.8058, LCminus [V] = 3.1331, 61011.729961435 2025-12-02T17:31:08.668000+00:00 110384 SetLockFreqs Linecenter [MHz AOM]: 75.506278, abs(B) [uT]: 44.987300000, EQS C1, C2, C4 [Hz]: 0.0, 0.0, 0.0 61011.729998368 2025-12-02T17:31:11.859000+00:00 110385 StateMachineSupervisor Start Clockrun 61011.730021227 2025-12-02T17:31:13.834000+00:00 110387 switchBeam Beam: B 61011.730030613 2025-12-02T17:31:14.645000+00:00 110388 Lock_to_C1234 t_probe [us] = 13700, n_shots = 1, g1 = 0.2, T_drift_s = 600.0, N_drift = 4200, pmt.thr = 22, pmt.thr2 = 10, T_p0avg_s = 900.0, N_p0avg = 2100, (C1, C2, C4) att [dB] = (15.00, 15.87, 15.65), att_RCDAT [dB] = 16.00, LCplus [V] = 1.8058, LCminus [V] = 3.1331, 61011.731074988 2025-12-02T17:32:44.879000+00:00 110390 StateMachineSupervisor Start Clockrun 61011.731098195 2025-12-02T17:32:46.884000+00:00 110392 switchBeam Beam: B 61011.731107535 2025-12-02T17:32:47.691000+00:00 110393 Lock_to_C1234 t_probe [us] = 13700, n_shots = 1, g1 = 0.0, T_drift_s = 600.0, N_drift = 4200, pmt.thr = 22, pmt.thr2 = 10, T_p0avg_s = 900.0, N_p0avg = 2100, (C1, C2, C4) att [dB] = (15.00, 15.87, 15.65), att_RCDAT [dB] = 16.00, LCplus [V] = 1.8058, LCminus [V] = 3.1331, 61011.734811875 2025-12-02T17:38:07.746000+00:00 110395 StateMachineSupervisor Start Clockrun 61011.734835000 2025-12-02T17:38:09.744000+00:00 110397 switchBeam Beam: B 61011.734845000 2025-12-02T17:38:10.608000+00:00 110398 Lock_to_C1234 t_probe [us] = 13700, n_shots = 1, g1 = 0.2, T_drift_s = 600.0, N_drift = 4200, pmt.thr = 22, pmt.thr2 = 10, T_p0avg_s = 900.0, N_p0avg = 2100, (C1, C2, C4) att [dB] = (15.00, 15.87, 15.65), att_RCDAT [dB] = 16.00, LCplus [V] = 1.8058, LCminus [V] = 3.1331, 61011.737376643 2025-12-02T17:41:49.342000+00:00 110400 SetLockFreqs Linecenter [MHz AOM]: 75.506306, abs(B) [uT]: 44.987500000, EQS C1, C2, C4 [Hz]: 0.0, 0.0, 0.0 61011.737430417 2025-12-02T17:41:53.988000+00:00 110401 StateMachineSupervisor Start Clockrun 61011.737454236 2025-12-02T17:41:56.046000+00:00 110403 switchBeam Beam: B 61011.737464132 2025-12-02T17:41:56.901000+00:00 110404 Lock_to_C1234 t_probe [us] = 13700, n_shots = 1, g1 = 0.2, T_drift_s = 600.0, N_drift = 4200, pmt.thr = 22, pmt.thr2 = 10, T_p0avg_s = 900.0, N_p0avg = 2100, (C1, C2, C4) att [dB] = (15.00, 15.87, 15.65), att_RCDAT [dB] = 16.00, LCplus [V] = 1.8058, LCminus [V] = 3.1331, 61011.738650081 2025-12-02T17:43:39.367000+00:00 110406 SetAtt att_RCDAT : 6.0 dB 61011.738675324 2025-12-02T17:43:41.548000+00:00 110407 StateMachineSupervisor Start Clockrun 61011.738698611 2025-12-02T17:43:43.560000+00:00 110409 switchBeam Beam: B 61011.738708137 2025-12-02T17:43:44.383000+00:00 110410 Lock_to_C1234 t_probe [us] = 1370, n_shots = 1, g1 = 0.0, T_drift_s = 600.0, N_drift = 6417, pmt.thr = 22, pmt.thr2 = 10, T_p0avg_s = 900.0, N_p0avg = 3209, (C1, C2, C4) att [dB] = (15.00, 15.87, 15.65), att_RCDAT [dB] = 6.00, LCplus [V] = 1.8058, LCminus [V] = 3.1331, 61011.739950486 2025-12-02T17:45:31.722000+00:00 110411 SetAtt att_RCDAT : 16.0 dB 61011.740033692 2025-12-02T17:45:38.911000+00:00 110413 StateMachineSupervisor Start Clockrun 61011.740057210 2025-12-02T17:45:40.943000+00:00 110415 switchBeam Beam: B 61011.740067535 2025-12-02T17:45:41.835000+00:00 110416 Lock_to_C1234 t_probe [us] = 13700, n_shots = 1, g1 = 0.1, T_drift_s = 600.0, N_drift = 4200, pmt.thr = 22, pmt.thr2 = 10, T_p0avg_s = 900.0, N_p0avg = 2100, (C1, C2, C4) att [dB] = (15.00, 15.87, 15.65), att_RCDAT [dB] = 16.00, LCplus [V] = 1.8058, LCminus [V] = 3.1331, 61011.741323125 2025-12-02T17:47:30.318000+00:00 110418 SetLockFreqs Linecenter [MHz AOM]: 75.506370, abs(B) [uT]: 44.987200000, EQS C1, C2, C4 [Hz]: 0.0, 0.0, 0.0 61011.741353715 2025-12-02T17:47:32.961000+00:00 110419 StateMachineSupervisor Start Clockrun 61011.741377165 2025-12-02T17:47:34.987000+00:00 110421 switchBeam Beam: B 61011.741386863 2025-12-02T17:47:35.825000+00:00 110422 Lock_to_C1234 t_probe [us] = 13700, n_shots = 1, g1 = 0.1, T_drift_s = 600.0, N_drift = 4200, pmt.thr = 22, pmt.thr2 = 10, T_p0avg_s = 900.0, N_p0avg = 2100, (C1, C2, C4) att [dB] = (15.00, 15.87, 15.65), att_RCDAT [dB] = 16.00, LCplus [V] = 1.8058, LCminus [V] = 3.1331, 61011.797305984 2025-12-02T19:08:07.237000+00:00 110424 SetAtt att_RCDAT : 23.0 dB 61011.797330139 2025-12-02T19:08:09.324000+00:00 110425 StateMachineSupervisor Start Clockrun 61011.797354306 2025-12-02T19:08:11.412000+00:00 110427 switchBeam Beam: B 61011.797364005 2025-12-02T19:08:12.250000+00:00 110428 Lock_to_C1234 t_probe [us] = 70000, n_shots = 1, g1 = 0.2, T_drift_s = 600.0, N_drift = 1629, pmt.thr = 22, pmt.thr2 = 10, T_p0avg_s = 900.0, N_p0avg = 815, (C1, C2, C4) att [dB] = (15.00, 15.87, 15.65), att_RCDAT [dB] = 23.00, LCplus [V] = 1.8058, LCminus [V] = 3.1331, 61011.810675070 2025-12-02T19:27:22.326000+00:00 110430 SetAtt att_RCDAT : 26.0 dB 61011.810849953 2025-12-02T19:27:37.436000+00:00 110431 StateMachineSupervisor Start Clockrun 61011.810873298 2025-12-02T19:27:39.453000+00:00 110433 switchBeam Beam: B 61011.810883079 2025-12-02T19:27:40.298000+00:00 110434 Lock_to_C1234 t_probe [us] = 137000, n_shots = 1, g1 = 0.2, T_drift_s = 600.0, N_drift = 942, pmt.thr = 22, pmt.thr2 = 10, T_p0avg_s = 900.0, N_p0avg = 471, (C1, C2, C4) att [dB] = (15.00, 15.87, 15.65), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8058, LCminus [V] = 3.1331, # End of file 61011_artiq_log.txt