# Start of file 60988_artiq_log.txt # First point: 60988.218458 2025-11-09T05:14:34.749000+00:00 # Last point: 60988.556427 2025-11-09T13:21:15.308000+00:00 # Num rows: 20 # File updated: 2025-11-10T01:11:11.075614 # Columns: MJD DATE RID PROGRAM MESSAGE 60988.218457743 2025-11-09T05:14:34.749000+00:00 109182 StateMachineSupervisor Ion Dark 60988.218463982 2025-11-09T05:14:35.288000+00:00 109182 StateMachineSupervisor Recover Ion 60988.218473252 2025-11-09T05:14:36.089000+00:00 109198 switchBeam Beam: ABC 60988.218504074 2025-11-09T05:14:38.752000+00:00 109201 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60988.218603519 2025-11-09T05:14:47.344000+00:00 109202 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 25.0. 60988.218622523 2025-11-09T05:14:48.986000+00:00 109204 switchBeam Beam: B 60988.218644503 2025-11-09T05:14:50.885000+00:00 109205 MeasureFluorescenceLevels Bright : 46.9 +- 6.8, Dark : 0.1 +- 0.3, Threshold: int( ceil( 1.7 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60988.218656319 2025-11-09T05:14:51.906000+00:00 109182 StateMachineSupervisor Ion Bright, Start Clockrun 60988.218688958 2025-11-09T05:14:54.726000+00:00 109208 switchBeam Beam: B 60988.218698310 2025-11-09T05:14:55.534000+00:00 109209 Lock_to_C124v2 t_probe [us] = 137000, n_shots = 1, g1 = 0.2, T_drift_s = 600.0, N_drift = 942, pmt.thr = 22, pmt.thr2 = 10, T_p0avg_s = 900.0, N_p0avg = 471, (C1, C2, C4) att [dB] = (15.00, 15.87, 15.65), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8058, LCminus [V] = 3.1331, 60988.556186493 2025-11-09T13:20:54.513000+00:00 109182 StateMachineSupervisor Ion Dark 60988.556192813 2025-11-09T13:20:55.059000+00:00 109182 StateMachineSupervisor Recover Ion 60988.556201864 2025-11-09T13:20:55.841000+00:00 109210 switchBeam Beam: ABC 60988.556233021 2025-11-09T13:20:58.533000+00:00 109213 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60988.556332245 2025-11-09T13:21:07.106000+00:00 109214 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 25.0. 60988.556350648 2025-11-09T13:21:08.696000+00:00 109216 switchBeam Beam: B 60988.556372488 2025-11-09T13:21:10.583000+00:00 109217 MeasureFluorescenceLevels Bright : 46.0 +- 6.0, Dark : 0.1 +- 0.3, Threshold: int( ceil( 2.0 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60988.556385162 2025-11-09T13:21:11.678000+00:00 109182 StateMachineSupervisor Ion Bright, Start Clockrun 60988.556417813 2025-11-09T13:21:14.499000+00:00 109220 switchBeam Beam: B 60988.556427176 2025-11-09T13:21:15.308000+00:00 109221 Lock_to_C124v2 t_probe [us] = 137000, n_shots = 1, g1 = 0.2, T_drift_s = 600.0, N_drift = 942, pmt.thr = 22, pmt.thr2 = 10, T_p0avg_s = 900.0, N_p0avg = 471, (C1, C2, C4) att [dB] = (15.00, 15.87, 15.65), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8058, LCminus [V] = 3.1331, # End of file 60988_artiq_log.txt