# Start of file 60977_artiq_log.txt # First point: 60977.833363 2025-10-29T20:00:02.521000+00:00 # Last point: 60977.919431 2025-10-29T22:03:58.846000+00:00 # Num rows: 20 # File updated: 2025-10-30T01:11:03.637562 # Columns: MJD DATE RID PROGRAM MESSAGE 60977.833362511 2025-10-29T20:00:02.521000+00:00 108185 StateMachineSupervisor Ion Dark 60977.833368704 2025-10-29T20:00:03.056000+00:00 108185 StateMachineSupervisor Recover Ion 60977.833378437 2025-10-29T20:00:03.897000+00:00 108417 switchBeam Beam: ABC 60977.833410174 2025-10-29T20:00:06.639000+00:00 108420 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60977.833508958 2025-10-29T20:00:15.174000+00:00 108421 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 25.0. 60977.833527674 2025-10-29T20:00:16.791000+00:00 108423 switchBeam Beam: B 60977.833549537 2025-10-29T20:00:18.680000+00:00 108424 MeasureFluorescenceLevels Bright : 48.7 +- 6.6, Dark : 0.1 +- 0.7, Threshold: int( ceil( 2.7 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60977.833561076 2025-10-29T20:00:19.677000+00:00 108185 StateMachineSupervisor Ion Bright, Start Clockrun 60977.833594386 2025-10-29T20:00:22.555000+00:00 108427 switchBeam Beam: B 60977.833603865 2025-10-29T20:00:23.374000+00:00 108428 Lock_to_C124v2 t_probe [us] = 217000, n_shots = 1, g1 = 0.2, T_drift_s = 600.0, N_drift = 627, pmt.thr = 22, pmt.thr2 = 10, T_p0avg_s = 900.0, N_p0avg = 313, (C1, C2, C4) att [dB] = (15.00, 15.87, 15.65), att_RCDAT [dB] = 28.00, LCplus [V] = 1.8010, LCminus [V] = 3.1293, 60977.919190127 2025-10-29T22:03:38.027000+00:00 108185 StateMachineSupervisor Ion Dark 60977.919196562 2025-10-29T22:03:38.583000+00:00 108185 StateMachineSupervisor Recover Ion 60977.919205625 2025-10-29T22:03:39.366000+00:00 108429 switchBeam Beam: ABC 60977.919237083 2025-10-29T22:03:42.084000+00:00 108432 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60977.919336181 2025-10-29T22:03:50.646000+00:00 108433 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 25.0. 60977.919354861 2025-10-29T22:03:52.260000+00:00 108435 switchBeam Beam: B 60977.919376794 2025-10-29T22:03:54.155000+00:00 108436 MeasureFluorescenceLevels Bright : 47.3 +- 7.7, Dark : 0.1 +- 0.5, Threshold: int( ceil( 2.1 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60977.919388831 2025-10-29T22:03:55.195000+00:00 108185 StateMachineSupervisor Ion Bright, Start Clockrun 60977.919421412 2025-10-29T22:03:58.010000+00:00 108439 switchBeam Beam: B 60977.919431088 2025-10-29T22:03:58.846000+00:00 108440 Lock_to_C124v2 t_probe [us] = 217000, n_shots = 1, g1 = 0.2, T_drift_s = 600.0, N_drift = 627, pmt.thr = 22, pmt.thr2 = 10, T_p0avg_s = 900.0, N_p0avg = 313, (C1, C2, C4) att [dB] = (15.00, 15.87, 15.65), att_RCDAT [dB] = 28.00, LCplus [V] = 1.8010, LCminus [V] = 3.1293, # End of file 60977_artiq_log.txt