# Start of file 60932_artiq_log.txt # First point: 60932.044663 2025-09-14T01:04:18.912000+00:00 # Last point: 60932.420548 2025-09-14T10:05:35.321000+00:00 # Num rows: 40 # File updated: 2025-09-15T00:10:49.099019 # Columns: MJD DATE RID PROGRAM MESSAGE 60932.044663333 2025-09-14T01:04:18.912000+00:00 103484 StateMachineSupervisor Ion Dark 60932.044669398 2025-09-14T01:04:19.436000+00:00 103484 StateMachineSupervisor Recover Ion 60932.044678553 2025-09-14T01:04:20.227000+00:00 103512 switchBeam Beam: ABC 60932.044710278 2025-09-14T01:04:22.968000+00:00 103515 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60932.044809618 2025-09-14T01:04:31.551000+00:00 103516 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 25.0. 60932.044828923 2025-09-14T01:04:33.219000+00:00 103518 switchBeam Beam: B 60932.044850914 2025-09-14T01:04:35.119000+00:00 103519 MeasureFluorescenceLevels Bright : 54.8 +- 6.4, Dark : 0.1 +- 0.3, Threshold: int( ceil( 1.7 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60932.044861863 2025-09-14T01:04:36.065000+00:00 103484 StateMachineSupervisor Ion Bright, Start Clockrun 60932.044894746 2025-09-14T01:04:38.906000+00:00 103522 switchBeam Beam: B 60932.044904236 2025-09-14T01:04:39.726000+00:00 103523 Lock_to_C124421 t_probe [us] = 140000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 462, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 231, (C1, C2, C4) att [dB] = (15.00, 15.76, 15.85), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8010, LCminus [V] = 3.1293, 60932.198842836 2025-09-14T04:46:20.021000+00:00 103484 StateMachineSupervisor Ion Dark 60932.198849039 2025-09-14T04:46:20.557000+00:00 103484 StateMachineSupervisor Recover Ion 60932.198858773 2025-09-14T04:46:21.398000+00:00 103524 switchBeam Beam: ABC 60932.198890336 2025-09-14T04:46:24.125000+00:00 103527 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60932.198989097 2025-09-14T04:46:32.658000+00:00 103528 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 25.0. 60932.199008067 2025-09-14T04:46:34.297000+00:00 103530 switchBeam Beam: B 60932.199030301 2025-09-14T04:46:36.218000+00:00 103531 MeasureFluorescenceLevels Bright : 55.2 +- 7.4, Dark : 0.1 +- 0.3, Threshold: int( ceil( 2.3 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60932.199041401 2025-09-14T04:46:37.177000+00:00 103484 StateMachineSupervisor Ion Bright, Start Clockrun 60932.199074977 2025-09-14T04:46:40.078000+00:00 103534 switchBeam Beam: B 60932.199085023 2025-09-14T04:46:40.946000+00:00 103535 Lock_to_C124421 t_probe [us] = 140000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 462, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 231, (C1, C2, C4) att [dB] = (15.00, 15.76, 15.85), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8010, LCminus [V] = 3.1293, 60932.403075984 2025-09-14T09:40:25.765000+00:00 103484 StateMachineSupervisor Ion Dark 60932.403082303 2025-09-14T09:40:26.311000+00:00 103484 StateMachineSupervisor Recover Ion 60932.403091446 2025-09-14T09:40:27.101000+00:00 103536 switchBeam Beam: ABC 60932.403123241 2025-09-14T09:40:29.848000+00:00 103539 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60932.403222083 2025-09-14T09:40:38.388000+00:00 103540 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 25.0. 60932.403241088 2025-09-14T09:40:40.030000+00:00 103542 switchBeam Beam: B 60932.403263079 2025-09-14T09:40:41.930000+00:00 103543 MeasureFluorescenceLevels Bright : 53.7 +- 6.4, Dark : 0.1 +- 0.3, Threshold: int( ceil( 2.3 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60932.403274583 2025-09-14T09:40:42.924000+00:00 103484 StateMachineSupervisor Ion Bright, Start Clockrun 60932.403307963 2025-09-14T09:40:45.808000+00:00 103546 switchBeam Beam: B 60932.403317419 2025-09-14T09:40:46.625000+00:00 103547 Lock_to_C124421 t_probe [us] = 140000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 462, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 231, (C1, C2, C4) att [dB] = (15.00, 15.76, 15.85), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8010, LCminus [V] = 3.1293, 60932.420306447 2025-09-14T10:05:14.477000+00:00 103484 StateMachineSupervisor Ion Dark 60932.420312685 2025-09-14T10:05:15.016000+00:00 103484 StateMachineSupervisor Recover Ion 60932.420321863 2025-09-14T10:05:15.809000+00:00 103548 switchBeam Beam: ABC 60932.420353449 2025-09-14T10:05:18.538000+00:00 103551 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60932.420452570 2025-09-14T10:05:27.102000+00:00 103552 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 25.0. 60932.420471806 2025-09-14T10:05:28.764000+00:00 103554 switchBeam Beam: B 60932.420493727 2025-09-14T10:05:30.658000+00:00 103555 MeasureFluorescenceLevels Bright : 53.5 +- 7.1, Dark : 0.1 +- 0.2, Threshold: int( ceil( 1.8 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60932.420505046 2025-09-14T10:05:31.636000+00:00 103484 StateMachineSupervisor Ion Bright, Start Clockrun 60932.420537963 2025-09-14T10:05:34.480000+00:00 103558 switchBeam Beam: B 60932.420547697 2025-09-14T10:05:35.321000+00:00 103559 Lock_to_C124421 t_probe [us] = 140000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 462, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 231, (C1, C2, C4) att [dB] = (15.00, 15.76, 15.85), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8010, LCminus [V] = 3.1293, # End of file 60932_artiq_log.txt