# Start of file 60920_artiq_log.txt # First point: 60920.292465 2025-09-02T07:01:08.937000+00:00 # Last point: 60920.938668 2025-09-02T22:31:40.926000+00:00 # Num rows: 70 # File updated: 2025-09-03T00:10:19.112798 # Columns: MJD DATE RID PROGRAM MESSAGE 60920.292464549 2025-09-02T07:01:08.937000+00:00 102908 StateMachineSupervisor Ion Dark 60920.292470822 2025-09-02T07:01:09.479000+00:00 102908 StateMachineSupervisor Recover Ion 60920.292480452 2025-09-02T07:01:10.311000+00:00 102996 switchBeam Beam: ABC 60920.292512292 2025-09-02T07:01:13.062000+00:00 102999 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60920.292610984 2025-09-02T07:01:21.589000+00:00 103000 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 25.0. 60920.292629757 2025-09-02T07:01:23.211000+00:00 103002 switchBeam Beam: B 60920.292652593 2025-09-02T07:01:25.184000+00:00 103003 MeasureFluorescenceLevels Bright : 32.2 +- 5.6, Dark : 0.0 +- 0.2, Threshold: int( ceil( 1.1 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60920.292663206 2025-09-02T07:01:26.101000+00:00 102908 StateMachineSupervisor Ion Bright, Start Clockrun 60920.292696377 2025-09-02T07:01:28.967000+00:00 103006 switchBeam Beam: B 60920.292705995 2025-09-02T07:01:29.798000+00:00 103007 Lock_to_C124421 t_probe [us] = 90000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 669, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 334, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 24.00, LCplus [V] = 1.8010, LCminus [V] = 3.1293, 60920.323830694 2025-09-02T07:46:18.972000+00:00 102908 StateMachineSupervisor Ion Dark 60920.323836759 2025-09-02T07:46:19.496000+00:00 102908 StateMachineSupervisor Recover Ion 60920.323845729 2025-09-02T07:46:20.271000+00:00 103008 switchBeam Beam: ABC 60920.323877674 2025-09-02T07:46:23.031000+00:00 103011 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60920.323977315 2025-09-02T07:46:31.640000+00:00 103012 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 25.0. 60920.323997118 2025-09-02T07:46:33.351000+00:00 103014 switchBeam Beam: B 60920.324019005 2025-09-02T07:46:35.242000+00:00 103015 MeasureFluorescenceLevels Bright : 31.1 +- 5.2, Dark : 0.1 +- 0.3, Threshold: int( ceil( 1.5 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60920.324029062 2025-09-02T07:46:36.111000+00:00 102908 StateMachineSupervisor Ion Bright, Start Clockrun 60920.324062835 2025-09-02T07:46:39.029000+00:00 103018 switchBeam Beam: B 60920.324072963 2025-09-02T07:46:39.904000+00:00 103019 Lock_to_C124421 t_probe [us] = 90000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 669, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 334, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 24.00, LCplus [V] = 1.8010, LCminus [V] = 3.1293, 60920.344537280 2025-09-02T08:16:08.021000+00:00 102908 StateMachineSupervisor Ion Dark 60920.344543600 2025-09-02T08:16:08.567000+00:00 102908 StateMachineSupervisor Recover Ion 60920.344553368 2025-09-02T08:16:09.411000+00:00 103020 switchBeam Beam: ABC 60920.344586111 2025-09-02T08:16:12.240000+00:00 103023 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60920.344683519 2025-09-02T08:16:20.656000+00:00 103024 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 25.0. 60920.344702326 2025-09-02T08:16:22.281000+00:00 103026 switchBeam Beam: B 60920.344724433 2025-09-02T08:16:24.191000+00:00 103027 MeasureFluorescenceLevels Bright : 28.6 +- 5.5, Dark : 0.1 +- 0.3, Threshold: int( ceil( 1.4 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60920.344735938 2025-09-02T08:16:25.185000+00:00 102908 StateMachineSupervisor Ion Bright, Start Clockrun 60920.344769468 2025-09-02T08:16:28.082000+00:00 103030 switchBeam Beam: B 60920.344779514 2025-09-02T08:16:28.950000+00:00 103031 Lock_to_C124421 t_probe [us] = 90000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 669, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 334, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 24.00, LCplus [V] = 1.8010, LCminus [V] = 3.1293, 60920.371964271 2025-09-02T08:55:37.713000+00:00 102908 StateMachineSupervisor Ion Dark 60920.371970440 2025-09-02T08:55:38.246000+00:00 102908 StateMachineSupervisor Recover Ion 60920.371979745 2025-09-02T08:55:39.050000+00:00 103032 switchBeam Beam: ABC 60920.372011724 2025-09-02T08:55:41.813000+00:00 103035 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60920.372110312 2025-09-02T08:55:50.331000+00:00 103036 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 25.0. 60920.372129386 2025-09-02T08:55:51.979000+00:00 103038 switchBeam Beam: B 60920.372151505 2025-09-02T08:55:53.890000+00:00 103039 MeasureFluorescenceLevels Bright : 28.6 +- 5.3, Dark : 0.1 +- 0.3, Threshold: int( ceil( 1.4 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60920.372162928 2025-09-02T08:55:54.877000+00:00 102908 StateMachineSupervisor Ion Bright, Start Clockrun 60920.372195798 2025-09-02T08:55:57.717000+00:00 103042 switchBeam Beam: B 60920.372205625 2025-09-02T08:55:58.566000+00:00 103043 Lock_to_C124421 t_probe [us] = 90000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 669, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 334, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 24.00, LCplus [V] = 1.8010, LCminus [V] = 3.1293, 60920.700745093 2025-09-02T16:49:04.376000+00:00 102908 StateMachineSupervisor Ion Dark 60920.700751262 2025-09-02T16:49:04.909000+00:00 102908 StateMachineSupervisor Recover Ion 60920.700760671 2025-09-02T16:49:05.722000+00:00 103044 switchBeam Beam: ABC 60920.700792037 2025-09-02T16:49:08.432000+00:00 103047 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60920.700891250 2025-09-02T16:49:17.004000+00:00 103048 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 25.0. 60920.700910081 2025-09-02T16:49:18.631000+00:00 103050 switchBeam Beam: B 60920.700932361 2025-09-02T16:49:20.556000+00:00 103051 MeasureFluorescenceLevels Bright : 55.2 +- 7.5, Dark : 0.1 +- 0.5, Threshold: int( ceil( 2.7 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60920.700943623 2025-09-02T16:49:21.529000+00:00 102908 StateMachineSupervisor Ion Bright, Start Clockrun 60920.700976551 2025-09-02T16:49:24.374000+00:00 103054 switchBeam Beam: B 60920.700986366 2025-09-02T16:49:25.222000+00:00 103055 Lock_to_C124421 t_probe [us] = 90000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 669, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 334, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 24.00, LCplus [V] = 1.8010, LCminus [V] = 3.1293, 60920.713456493 2025-09-02T17:07:22.641000+00:00 102908 StateMachineSupervisor Ion Dark 60920.713462650 2025-09-02T17:07:23.173000+00:00 102908 StateMachineSupervisor Recover Ion 60920.713471713 2025-09-02T17:07:23.956000+00:00 103056 switchBeam Beam: ABC 60920.713503900 2025-09-02T17:07:26.737000+00:00 103059 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60920.713602593 2025-09-02T17:07:35.264000+00:00 103060 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 25.0. 60920.713621609 2025-09-02T17:07:36.907000+00:00 103062 switchBeam Beam: B 60920.713643576 2025-09-02T17:07:38.805000+00:00 103063 MeasureFluorescenceLevels Bright : 55.5 +- 7.2, Dark : 0.1 +- 0.2, Threshold: int( ceil( 1.8 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60920.713655093 2025-09-02T17:07:39.800000+00:00 102908 StateMachineSupervisor Ion Bright, Start Clockrun 60920.713688334 2025-09-02T17:07:42.672000+00:00 103066 switchBeam Beam: B 60920.713697951 2025-09-02T17:07:43.503000+00:00 103067 Lock_to_C124421 t_probe [us] = 90000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 669, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 334, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 24.00, LCplus [V] = 1.8010, LCminus [V] = 3.1293, 60920.938426586 2025-09-02T22:31:20.057000+00:00 102908 StateMachineSupervisor Ion Dark 60920.938432604 2025-09-02T22:31:20.577000+00:00 102908 StateMachineSupervisor Recover Ion 60920.938442280 2025-09-02T22:31:21.413000+00:00 103068 switchBeam Beam: ABC 60920.938474086 2025-09-02T22:31:24.161000+00:00 103071 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60920.938572952 2025-09-02T22:31:32.703000+00:00 103072 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 25.0. 60920.938591620 2025-09-02T22:31:34.316000+00:00 103074 switchBeam Beam: B 60920.938613843 2025-09-02T22:31:36.236000+00:00 103075 MeasureFluorescenceLevels Bright : 57.1 +- 6.9, Dark : 0.1 +- 0.3, Threshold: int( ceil( 2.1 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60920.938625012 2025-09-02T22:31:37.201000+00:00 102908 StateMachineSupervisor Ion Bright, Start Clockrun 60920.938658507 2025-09-02T22:31:40.095000+00:00 103078 switchBeam Beam: B 60920.938668125 2025-09-02T22:31:40.926000+00:00 103079 Lock_to_C124421 t_probe [us] = 90000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 669, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 334, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 24.00, LCplus [V] = 1.8010, LCminus [V] = 3.1293, # End of file 60920_artiq_log.txt