# Start of file 60792_artiq_log.txt # First point: 60792.211037 2025-04-27T05:03:53.591000+00:00 # Last point: 60792.937652 2025-04-27T22:30:13.134000+00:00 # Num rows: 112 # File updated: 2025-04-28T00:10:48.250673 # Columns: MJD DATE RID PROGRAM MESSAGE 60792.211036933 2025-04-27T05:03:53.591000+00:00 97764 MeasureFluorescenceLevels Bright : 41.5 +- 6.2, Dark : 0.2 +- 0.7, Threshold: int( ceil( 2.6 ) ) = 3, N_meas = 50, t_gate = 5.0 ms 60792.212051852 2025-04-27T05:05:21.280000+00:00 97765 SetCoolingAOM mode : umotion, AOM_f (MHz) : 207.5, ATT_Main (dB) = 6.0, ATT_SP (dB) = 17.0. 60792.212816690 2025-04-27T05:06:27.362000+00:00 97766 MicroMotionMeasurement3Beam Beam: B, N_photons: 400000, N_bins: 25, f_mod [MHz]: 14.362000, duration [s]: 59.940 60792.212830139 2025-04-27T05:06:28.524000+00:00 97767 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60792.212839167 2025-04-27T05:06:29.304000+00:00 97768 switchBeam Beam: B 60792.213008611 2025-04-27T05:06:43.944000+00:00 97769 SecularXYZ3 N_photons: 3000, num_pts: 101, TicklerAtt (attX, attY, attZ) [dB]: (19.0, 15.0, 30.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.885000, 0.222000, 14.803100, 96.951700) 60792.215827488 2025-04-27T05:10:47.495000+00:00 97770 MeasureFluorescenceLevels Bright : 42.3 +- 5.5, Dark : 0.1 +- 0.3, Threshold: int( ceil( 1.8 ) ) = 2, N_meas = 50, t_gate = 5.0 ms 60792.458307697 2025-04-27T10:59:57.785000+00:00 97787 MeasureFluorescenceLevels Bright : 41.2 +- 6.5, Dark : 0.1 +- 0.4, Threshold: int( ceil( 1.8 ) ) = 2, N_meas = 50, t_gate = 5.0 ms 60792.602175070 2025-04-27T14:27:07.926000+00:00 97798 MeasureFluorescenceLevels Bright : 41.0 +- 6.5, Dark : 0.1 +- 0.2, Threshold: int( ceil( 1.6 ) ) = 2, N_meas = 50, t_gate = 5.0 ms 60792.602928912 2025-04-27T14:28:13.058000+00:00 97800 SetAtt att_RCDAT : 0.0 dB 60792.611643669 2025-04-27T14:40:46.013000+00:00 97802 setBiasVoltagesDiff V1_V2_cm: -5.885000, V1_V2_diff: 0.222000, V3_V4_cm: 14.803100, V3_V4_diff: 96.951700 60792.617750162 2025-04-27T14:49:33.614000+00:00 97804 SetCoolingAOM mode : umotion, AOM_f (MHz) : 207.5, ATT_Main (dB) = 6.0, ATT_SP (dB) = 17.0. 60792.618687315 2025-04-27T14:50:54.584000+00:00 97805 MicroMotionMeasurement3Beam Beam: B, N_photons: 400000, N_bins: 25, f_mod [MHz]: 14.362000, duration [s]: 62.256 60792.618700440 2025-04-27T14:50:55.718000+00:00 97806 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60792.618709977 2025-04-27T14:50:56.542000+00:00 97807 switchBeam Beam: B 60792.618726296 2025-04-27T14:50:57.952000+00:00 97808 MeasureFluorescenceLevels Bright : 41.6 +- 7.6, Dark : 0.1 +- 0.2, Threshold: int( ceil( 1.6 ) ) = 2, N_meas = 50, t_gate = 5.0 ms 60792.621201528 2025-04-27T14:54:31.812000+00:00 97809 StateMachineSupervisor Start Clockrun 60792.621225127 2025-04-27T14:54:33.851000+00:00 97811 switchBeam Beam: B 60792.621234931 2025-04-27T14:54:34.698000+00:00 97812 Lock_to_C124421 t_probe [us] = 700, n_shots = 1, g1 = 0.0, T_drift_s = 600.0, N_drift = 3303, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 1651, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 0.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60792.634791447 2025-04-27T15:14:05.981000+00:00 97814 SetAtt att_RCDAT : 16.0 dB 60792.634868287 2025-04-27T15:14:12.620000+00:00 97815 StateMachineSupervisor Start Clockrun 60792.634892072 2025-04-27T15:14:14.675000+00:00 97817 switchBeam Beam: B 60792.634901898 2025-04-27T15:14:15.524000+00:00 97818 Lock_to_C124421 t_probe [us] = 25000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1593, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 797, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 16.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60792.637330428 2025-04-27T15:17:45.349000+00:00 97820 SetAtt att_RCDAT : 19.0 dB 60792.637348982 2025-04-27T15:17:46.952000+00:00 97821 StateMachineSupervisor Start Clockrun 60792.637372685 2025-04-27T15:17:49+00:00 97823 switchBeam Beam: B 60792.637382708 2025-04-27T15:17:49.866000+00:00 97824 Lock_to_C124421 t_probe [us] = 50000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1041, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 520, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 19.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60792.643532581 2025-04-27T15:26:41.215000+00:00 97826 SetAtt att_RCDAT : 22.0 dB 60792.643547176 2025-04-27T15:26:42.476000+00:00 97827 StateMachineSupervisor Start Clockrun 60792.643571806 2025-04-27T15:26:44.604000+00:00 97829 switchBeam Beam: B 60792.643581921 2025-04-27T15:26:45.478000+00:00 97830 Lock_to_C124421 t_probe [us] = 100000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 612, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 307, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 22.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60792.645981157 2025-04-27T15:30:12.772000+00:00 97831 SetAtt att_RCDAT : 19.0 dB 60792.646015729 2025-04-27T15:30:15.759000+00:00 97833 StateMachineSupervisor Start Clockrun 60792.646040637 2025-04-27T15:30:17.911000+00:00 97835 switchBeam Beam: B 60792.646051539 2025-04-27T15:30:18.853000+00:00 97836 Lock_to_C124421 t_probe [us] = 50000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1041, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 520, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 19.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60792.678815266 2025-04-27T16:17:29.639000+00:00 97837 SetAtt att_RCDAT : 0.0 dB 60792.679531840 2025-04-27T16:18:31.551000+00:00 97839 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 0.0, 60792.681376574 2025-04-27T16:21:10.936000+00:00 97840 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 50.0, 60792.684407824 2025-04-27T16:25:32.836000+00:00 97841 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 100.0, 60792.688625289 2025-04-27T16:31:37.225000+00:00 97842 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 150.0, 60792.694028924 2025-04-27T16:39:24.099000+00:00 97843 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 200.0, 60792.694687488 2025-04-27T16:40:20.999000+00:00 97844 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 0.0, 60792.694687870 2025-04-27T16:40:21.032000+00:00 97845 SecularXYZ3 N_photons: 3000, num_pts: 101, TicklerAtt (attX, attY, attZ) [dB]: (19.0, 15.0, 30.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.885000, 0.222000, 14.803100, 96.951700) 60792.696945231 2025-04-27T16:43:36.068000+00:00 97846 SetAtt att_RCDAT : 19.0 dB 60792.697016180 2025-04-27T16:43:42.198000+00:00 97847 StateMachineSupervisor Start Clockrun 60792.697040915 2025-04-27T16:43:44.335000+00:00 97849 switchBeam Beam: B 60792.697050486 2025-04-27T16:43:45.162000+00:00 97850 Lock_to_C124421 t_probe [us] = 50000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1041, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 520, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 19.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60792.697943889 2025-04-27T16:45:02.352000+00:00 97851 SetAtt att_RCDAT : 16.0 dB 60792.697981979 2025-04-27T16:45:05.643000+00:00 97853 StateMachineSupervisor Start Clockrun 60792.698006088 2025-04-27T16:45:07.726000+00:00 97855 switchBeam Beam: B 60792.698016354 2025-04-27T16:45:08.613000+00:00 97856 Lock_to_C124421 t_probe [us] = 25000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1593, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 797, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 16.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60792.699257361 2025-04-27T16:46:55.836000+00:00 97857 SetAtt att_RCDAT : 19.0 dB 60792.699292627 2025-04-27T16:46:58.883000+00:00 97859 StateMachineSupervisor Start Clockrun 60792.699316782 2025-04-27T16:47:00.970000+00:00 97861 switchBeam Beam: B 60792.699326910 2025-04-27T16:47:01.845000+00:00 97862 Lock_to_C124421 t_probe [us] = 50000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1041, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 520, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 19.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60792.730111285 2025-04-27T17:31:21.615000+00:00 97859 StateMachineSupervisor Ion Dark 60792.730117511 2025-04-27T17:31:22.153000+00:00 97859 StateMachineSupervisor Recover Ion 60792.730127211 2025-04-27T17:31:22.991000+00:00 97863 switchBeam Beam: ABC 60792.730159155 2025-04-27T17:31:25.751000+00:00 97866 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60792.730257616 2025-04-27T17:31:34.258000+00:00 97867 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60792.730277743 2025-04-27T17:31:35.997000+00:00 97869 switchBeam Beam: B 60792.730300312 2025-04-27T17:31:37.947000+00:00 97870 MeasureFluorescenceLevels Bright : 43.0 +- 6.3, Dark : 0.1 +- 0.3, Threshold: int( ceil( 1.7 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60792.730309803 2025-04-27T17:31:38.767000+00:00 97859 StateMachineSupervisor Ion Bright, Start Clockrun 60792.730343530 2025-04-27T17:31:41.681000+00:00 97873 switchBeam Beam: B 60792.730353680 2025-04-27T17:31:42.558000+00:00 97874 Lock_to_C124421 t_probe [us] = 50000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1041, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 520, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 19.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60792.740171227 2025-04-27T17:45:50.794000+00:00 97875 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60792.740214769 2025-04-27T17:45:54.556000+00:00 97877 MeasureFluorescenceLevels Bright : 43.8 +- 5.9, Dark : 0.1 +- 0.2, Threshold: int( ceil( 1.6 ) ) = 2, N_meas = 50, t_gate = 5.0 ms 60792.740308194 2025-04-27T17:46:02.628000+00:00 97879 MeasureFluorescenceLevels Bright : 43.6 +- 6.7, Dark : 0.1 +- 0.5, Threshold: int( ceil( 2.3 ) ) = 3, N_meas = 50, t_gate = 5.0 ms 60792.740540023 2025-04-27T17:46:22.658000+00:00 97880 SecularXYZ3 N_photons: 3000, num_pts: 101, TicklerAtt (attX, attY, attZ) [dB]: (19.0, 15.0, 30.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.885000, 0.222000, 14.803100, 96.951700) 60792.742797454 2025-04-27T17:49:37.700000+00:00 97881 SetAtt att_RCDAT : 0.0 dB 60792.743600451 2025-04-27T17:50:47.079000+00:00 97882 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 0.0, 60792.745446609 2025-04-27T17:53:26.587000+00:00 97883 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 50.0, 60792.748478472 2025-04-27T17:57:48.540000+00:00 97884 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 100.0, 60792.752695556 2025-04-27T18:03:52.896000+00:00 97885 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 150.0, 60792.758099051 2025-04-27T18:11:39.758000+00:00 97886 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 200.0, 60792.758757755 2025-04-27T18:12:36.670000+00:00 97887 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 0.0, 60792.759415995 2025-04-27T18:13:33.542000+00:00 97888 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 0.0, 60792.759416412 2025-04-27T18:13:33.578000+00:00 97889 SecularXYZ3 N_photons: 3000, num_pts: 101, TicklerAtt (attX, attY, attZ) [dB]: (19.0, 15.0, 30.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.885000, 0.222000, 14.803100, 96.951700) 60792.762898611 2025-04-27T18:18:34.440000+00:00 97890 SetAtt att_RCDAT : 19.0 dB 60792.762932060 2025-04-27T18:18:37.330000+00:00 97891 StateMachineSupervisor Start Clockrun 60792.762957176 2025-04-27T18:18:39.500000+00:00 97893 switchBeam Beam: B 60792.762967130 2025-04-27T18:18:40.360000+00:00 97894 Lock_to_C124421 t_probe [us] = 50000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1041, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 520, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 19.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60792.763396933 2025-04-27T18:19:17.495000+00:00 97895 SetAtt att_RCDAT : 16.0 dB 60792.763434028 2025-04-27T18:19:20.700000+00:00 97897 StateMachineSupervisor Start Clockrun 60792.763457928 2025-04-27T18:19:22.765000+00:00 97899 switchBeam Beam: B 60792.763468391 2025-04-27T18:19:23.669000+00:00 97900 Lock_to_C124421 t_probe [us] = 25000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1593, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 797, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 16.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60792.765424248 2025-04-27T18:22:12.655000+00:00 97902 SetAtt att_RCDAT : 6.0 dB 60792.765495648 2025-04-27T18:22:18.824000+00:00 97903 StateMachineSupervisor Start Clockrun 60792.765519942 2025-04-27T18:22:20.923000+00:00 97905 switchBeam Beam: B 60792.765529896 2025-04-27T18:22:21.783000+00:00 97906 Lock_to_C124421 t_probe [us] = 2500, n_shots = 1, g1 = 0.0, T_drift_s = 600.0, N_drift = 3060, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 1530, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 6.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60792.766770752 2025-04-27T18:24:08.993000+00:00 97907 SetAtt att_RCDAT : 16.0 dB 60792.766800393 2025-04-27T18:24:11.554000+00:00 97909 StateMachineSupervisor Start Clockrun 60792.766824711 2025-04-27T18:24:13.655000+00:00 97911 switchBeam Beam: B 60792.766834699 2025-04-27T18:24:14.518000+00:00 97912 Lock_to_C124421 t_probe [us] = 25000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1593, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 797, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 16.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60792.768647419 2025-04-27T18:26:51.137000+00:00 97914 SetAtt att_RCDAT : 19.0 dB 60792.768666875 2025-04-27T18:26:52.818000+00:00 97915 StateMachineSupervisor Start Clockrun 60792.768691747 2025-04-27T18:26:54.967000+00:00 97917 switchBeam Beam: B 60792.768701609 2025-04-27T18:26:55.819000+00:00 97918 Lock_to_C124421 t_probe [us] = 50000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1041, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 520, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 19.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60792.770077824 2025-04-27T18:28:54.724000+00:00 97920 SetAtt att_RCDAT : 22.0 dB 60792.770103032 2025-04-27T18:28:56.902000+00:00 97921 StateMachineSupervisor Start Clockrun 60792.770128090 2025-04-27T18:28:59.067000+00:00 97923 switchBeam Beam: B 60792.770138461 2025-04-27T18:28:59.963000+00:00 97924 Lock_to_C124421 t_probe [us] = 100000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 612, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 307, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 22.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60792.937404039 2025-04-27T22:29:51.709000+00:00 97921 StateMachineSupervisor Ion Dark 60792.937410266 2025-04-27T22:29:52.247000+00:00 97921 StateMachineSupervisor Recover Ion 60792.937419977 2025-04-27T22:29:53.086000+00:00 97925 switchBeam Beam: ABC 60792.937452234 2025-04-27T22:29:55.873000+00:00 97928 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60792.937551065 2025-04-27T22:30:04.412000+00:00 97929 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60792.937571389 2025-04-27T22:30:06.168000+00:00 97931 switchBeam Beam: B 60792.937595104 2025-04-27T22:30:08.217000+00:00 97932 MeasureFluorescenceLevels Bright : 39.3 +- 6.2, Dark : 0.1 +- 0.3, Threshold: int( ceil( 1.7 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60792.937608229 2025-04-27T22:30:09.351000+00:00 97921 StateMachineSupervisor Ion Bright, Start Clockrun 60792.937641979 2025-04-27T22:30:12.267000+00:00 97935 switchBeam Beam: B 60792.937652014 2025-04-27T22:30:13.134000+00:00 97936 Lock_to_C124421 t_probe [us] = 100000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 612, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 307, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 22.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, # End of file 60792_artiq_log.txt