# Start of file 60790_artiq_log.txt # First point: 60790.155328 2025-04-25T03:43:40.357000+00:00 # Last point: 60790.679417 2025-04-25T16:18:21.595000+00:00 # Num rows: 156 # File updated: 2025-04-26T00:11:04.577111 # Columns: MJD DATE RID PROGRAM MESSAGE 60790.155328206 2025-04-25T03:43:40.357000+00:00 97482 StateMachineSupervisor Ion Dark 60790.155334514 2025-04-25T03:43:40.902000+00:00 97482 StateMachineSupervisor Recover Ion 60790.155397790 2025-04-25T03:43:46.369000+00:00 97510 switchBeam Beam: ABC 60790.155538402 2025-04-25T03:43:58.518000+00:00 97513 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60790.155586354 2025-04-25T03:44:02.661000+00:00 97514 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60790.155669514 2025-04-25T03:44:09.846000+00:00 97516 switchBeam Beam: B 60790.155738067 2025-04-25T03:44:15.769000+00:00 97517 MeasureFluorescenceLevels Bright : 39.1 +- 6.0, Dark : 0.1 +- 0.2, Threshold: int( ceil( 1.4 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60790.155755208 2025-04-25T03:44:17.250000+00:00 97482 StateMachineSupervisor Ion Bright, Start Clockrun 60790.155898044 2025-04-25T03:44:29.591000+00:00 97520 switchBeam Beam: B 60790.155952697 2025-04-25T03:44:34.313000+00:00 97521 Lock_to_C124421 t_probe [us] = 103000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 600, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 300, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 22.00, LCplus [V] = 1.8379, LCminus [V] = 3.2511, 60790.248304988 2025-04-25T05:57:33.551000+00:00 97523 SetCoolingAOM mode : umotion, AOM_f (MHz) : 207.5, ATT_Main (dB) = 6.0, ATT_SP (dB) = 17.0. 60790.249309827 2025-04-25T05:59:00.369000+00:00 97524 MicroMotionMeasurement3Beam Beam: B, N_photons: 400000, N_bins: 25, f_mod [MHz]: 14.362000, duration [s]: 76.667 60790.251061377 2025-04-25T06:01:31.703000+00:00 97525 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60790.251121076 2025-04-25T06:01:36.861000+00:00 97526 switchBeam Beam: B 60790.251344734 2025-04-25T06:01:56.185000+00:00 97527 SecularXYZ3 N_photons: 3000, num_pts: 201, TicklerAtt (attX, attY, attZ) [dB]: (19.0, 15.0, 30.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.885000, 0.222000, 14.803100, 96.951700) 60790.343807130 2025-04-25T08:15:04.936000+00:00 97528 MeasureFluorescenceLevels Bright : 38.3 +- 6.9, Dark : 0.0 +- 0.3, Threshold: int( ceil( 1.2 ) ) = 2, N_meas = 50, t_gate = 5.0 ms 60790.349776180 2025-04-25T08:23:40.662000+00:00 97529 MeasureFluorescenceLevels Bright : 37.2 +- 6.0, Dark : 0.1 +- 0.3, Threshold: int( ceil( 1.7 ) ) = 2, N_meas = 50, t_gate = 5.0 ms 60790.352705428 2025-04-25T08:27:53.749000+00:00 97530 SetLockFreqs Linecenter [MHz AOM]: 75.559290, abs(B) [uT]: 4.798600000, EQS C1, C2, C4 [Hz]: 0.0, 0.0, 0.0 60790.352915648 2025-04-25T08:28:11.912000+00:00 97531 switchBeam Beam: A 60790.354423831 2025-04-25T08:30:22.219000+00:00 97532 ScanLCFit LCplus start [V]: 1.700, LCplus stop [V]: 2.100, num_points: 100, LCminus start [V]: 2.600, LCminus stop [V]: 4.500, num_points: 100, t_gate [ms]: 100, 60790.356967581 2025-04-25T08:34:01.999000+00:00 97533 switchBeam Beam: B 60790.357001320 2025-04-25T08:34:04.914000+00:00 97534 MeasureFluorescenceLevels Bright : 40.0 +- 6.2, Dark : 0.1 +- 0.3, Threshold: int( ceil( 1.8 ) ) = 2, N_meas = 50, t_gate = 5.0 ms 60790.357881435 2025-04-25T08:35:20.956000+00:00 97535 SetLockFreqs Linecenter [MHz AOM]: 75.559287, abs(B) [uT]: 4.798600000, EQS C1, C2, C4 [Hz]: 0.0, 0.0, 0.0 60790.358149375 2025-04-25T08:35:44.106000+00:00 97536 StateMachineSupervisor Start Clockrun 60790.358172292 2025-04-25T08:35:46.086000+00:00 97538 switchBeam Beam: B 60790.358959028 2025-04-25T08:36:54.060000+00:00 97540 StateMachineSupervisor Start Clockrun 60790.358981713 2025-04-25T08:36:56.020000+00:00 97542 switchBeam Beam: B 60790.359501285 2025-04-25T08:37:40.911000+00:00 97544 StateMachineSupervisor Start Clockrun 60790.359524699 2025-04-25T08:37:42.934000+00:00 97546 switchBeam Beam: B 60790.359534097 2025-04-25T08:37:43.746000+00:00 97547 Lock_to_C124421 t_probe [us] = 103000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 600, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 300, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 22.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.360198877 2025-04-25T08:38:41.183000+00:00 97548 SetAtt att_RCDAT : 16.0 dB 60790.360245822 2025-04-25T08:38:45.239000+00:00 97550 StateMachineSupervisor Start Clockrun 60790.360268646 2025-04-25T08:38:47.211000+00:00 97552 switchBeam Beam: B 60790.360277963 2025-04-25T08:38:48.016000+00:00 97553 Lock_to_C124421 t_probe [us] = 25000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1593, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 797, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 16.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.399525787 2025-04-25T09:35:19.028000+00:00 97550 StateMachineSupervisor Ion Dark 60790.399531864 2025-04-25T09:35:19.553000+00:00 97550 StateMachineSupervisor Recover Ion 60790.399541620 2025-04-25T09:35:20.396000+00:00 97554 switchBeam Beam: ABC 60790.399573264 2025-04-25T09:35:23.130000+00:00 97557 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60790.399671516 2025-04-25T09:35:31.619000+00:00 97558 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60790.399690127 2025-04-25T09:35:33.227000+00:00 97560 switchBeam Beam: B 60790.399711991 2025-04-25T09:35:35.116000+00:00 97561 MeasureFluorescenceLevels Bright : 38.0 +- 6.5, Dark : 0.1 +- 0.3, Threshold: int( ceil( 1.7 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60790.399724248 2025-04-25T09:35:36.175000+00:00 97550 StateMachineSupervisor Ion Bright, Start Clockrun 60790.399756806 2025-04-25T09:35:38.988000+00:00 97564 switchBeam Beam: B 60790.399766169 2025-04-25T09:35:39.797000+00:00 97565 Lock_to_C124421 t_probe [us] = 25000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1593, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 797, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 16.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.512050961 2025-04-25T12:17:21.203000+00:00 97567 SetAtt att_RCDAT : 22.0 dB 60790.512079086 2025-04-25T12:17:23.633000+00:00 97568 StateMachineSupervisor Start Clockrun 60790.512102164 2025-04-25T12:17:25.627000+00:00 97570 switchBeam Beam: B 60790.512111597 2025-04-25T12:17:26.442000+00:00 97571 Lock_to_C124421 t_probe [us] = 103000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 600, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 300, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 22.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.528360764 2025-04-25T12:40:50.370000+00:00 97573 SetAtt att_RCDAT : 0.0 dB 60790.529632349 2025-04-25T12:42:40.235000+00:00 97574 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 0.0, 60790.530887338 2025-04-25T12:44:28.666000+00:00 97575 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 25.0, 60790.532731273 2025-04-25T12:47:07.982000+00:00 97576 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 50.0, 60790.535168299 2025-04-25T12:50:38.541000+00:00 97577 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 75.0, 60790.538198206 2025-04-25T12:55:00.325000+00:00 97578 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 100.0, 60790.541822697 2025-04-25T13:00:13.481000+00:00 97579 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 125.0, 60790.546040081 2025-04-25T13:06:17.863000+00:00 97580 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 150.0, 60790.550850393 2025-04-25T13:13:13.474000+00:00 97581 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 175.0, 60790.556253253 2025-04-25T13:21:00.281000+00:00 97582 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 200.0, 60790.556911238 2025-04-25T13:21:57.131000+00:00 97583 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 0.0, 60790.556911435 2025-04-25T13:21:57.148000+00:00 97584 SecularXYZ3 N_photons: 3000, num_pts: 201, TicklerAtt (attX, attY, attZ) [dB]: (19.0, 15.0, 30.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.885000, 0.222000, 14.803100, 96.951700) 60790.561495949 2025-04-25T13:28:33.250000+00:00 97586 MeasureFluorescenceLevels Bright : 38.3 +- 6.3, Dark : 0.0 +- 0.2, Threshold: int( ceil( 1.2 ) ) = 2, N_meas = 50, t_gate = 5.0 ms 60790.561783426 2025-04-25T13:28:58.088000+00:00 97587 SecularXYZ3 N_photons: 3000, num_pts: 201, TicklerAtt (attX, attY, attZ) [dB]: (19.0, 15.0, 30.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.885000, 0.222000, 14.803100, 96.951700) 60790.566273785 2025-04-25T13:35:26.055000+00:00 97588 SetAtt att_RCDAT : 22.0 dB 60790.566295810 2025-04-25T13:35:27.958000+00:00 97589 StateMachineSupervisor Start Clockrun 60790.566319051 2025-04-25T13:35:29.966000+00:00 97591 switchBeam Beam: B 60790.566329653 2025-04-25T13:35:30.882000+00:00 97592 Lock_to_C124421 t_probe [us] = 103000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 600, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 300, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 22.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.567576169 2025-04-25T13:37:18.581000+00:00 97593 SetAtt att_RCDAT : 16.0 dB 60790.567625428 2025-04-25T13:37:22.837000+00:00 97595 StateMachineSupervisor Start Clockrun 60790.567649005 2025-04-25T13:37:24.874000+00:00 97597 switchBeam Beam: B 60790.567658588 2025-04-25T13:37:25.702000+00:00 97598 Lock_to_C124421 t_probe [us] = 25000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1593, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 797, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 16.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.569744769 2025-04-25T13:40:25.948000+00:00 97600 SetAtt att_RCDAT : 19.0 dB 60790.569767257 2025-04-25T13:40:27.891000+00:00 97601 StateMachineSupervisor Start Clockrun 60790.569790648 2025-04-25T13:40:29.912000+00:00 97603 switchBeam Beam: B 60790.569800475 2025-04-25T13:40:30.761000+00:00 97604 Lock_to_C124421 t_probe [us] = 50000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1041, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 520, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 19.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.571775949 2025-04-25T13:43:21.442000+00:00 97606 SetAtt att_RCDAT : 22.0 dB 60790.571791354 2025-04-25T13:43:22.773000+00:00 97607 StateMachineSupervisor Start Clockrun 60790.571815000 2025-04-25T13:43:24.816000+00:00 97609 switchBeam Beam: B 60790.571824329 2025-04-25T13:43:25.622000+00:00 97610 Lock_to_C124421 t_probe [us] = 100000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 612, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 307, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 22.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.575996690 2025-04-25T13:49:26.114000+00:00 97612 SetAtt att_RCDAT : 19.0 dB 60790.576049190 2025-04-25T13:49:30.650000+00:00 97613 StateMachineSupervisor Start Clockrun 60790.576072720 2025-04-25T13:49:32.683000+00:00 97615 switchBeam Beam: B 60790.576082188 2025-04-25T13:49:33.501000+00:00 97616 Lock_to_C124421 t_probe [us] = 50000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1041, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 520, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 19.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.578734479 2025-04-25T13:53:22.659000+00:00 97618 SetAtt att_RCDAT : 0.0 dB 60790.579434456 2025-04-25T13:54:23.137000+00:00 97619 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 0.0, 60790.580685290 2025-04-25T13:56:11.209000+00:00 97620 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 25.0, 60790.582529525 2025-04-25T13:58:50.551000+00:00 97621 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 50.0, 60790.584966678 2025-04-25T14:02:21.121000+00:00 97622 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 75.0, 60790.587997280 2025-04-25T14:06:42.965000+00:00 97623 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 100.0, 60790.591621157 2025-04-25T14:11:56.068000+00:00 97624 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 125.0, 60790.595837442 2025-04-25T14:18:00.355000+00:00 97625 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 150.0, 60790.600647430 2025-04-25T14:24:55.938000+00:00 97626 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 175.0, 60790.606051262 2025-04-25T14:32:42.829000+00:00 97627 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 200.0, 60790.606709294 2025-04-25T14:33:39.683000+00:00 97628 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 0.0, 60790.607027211 2025-04-25T14:34:07.151000+00:00 97629 SecularXYZ3 N_photons: 3000, num_pts: 201, TicklerAtt (attX, attY, attZ) [dB]: (19.0, 15.0, 30.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.885000, 0.222000, 14.803100, 96.951700) 60790.615597743 2025-04-25T14:46:27.645000+00:00 97630 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 0.0, 60790.616283414 2025-04-25T14:47:26.887000+00:00 97631 RabiFlopping freq_mode C1+ ,sideband_mode +X,start_delay 0.0, 60790.616941574 2025-04-25T14:48:23.752000+00:00 97632 RabiFlopping freq_mode C1+ ,sideband_mode -X,start_delay 0.0, 60790.617599155 2025-04-25T14:49:20.567000+00:00 97633 RabiFlopping freq_mode C1+ ,sideband_mode +Y,start_delay 0.0, 60790.618257396 2025-04-25T14:50:17.439000+00:00 97634 RabiFlopping freq_mode C1+ ,sideband_mode -Y,start_delay 0.0, 60790.618916852 2025-04-25T14:51:14.416000+00:00 97635 RabiFlopping freq_mode C1+ ,sideband_mode +Z,start_delay 0.0, 60790.619575301 2025-04-25T14:52:11.306000+00:00 97636 RabiFlopping freq_mode C1+ ,sideband_mode -Z,start_delay 0.0, 60790.619666493 2025-04-25T14:52:19.185000+00:00 97637 SetAtt att_RCDAT : 19.0 dB 60790.619754618 2025-04-25T14:52:26.799000+00:00 97638 StateMachineSupervisor Start Clockrun 60790.619780174 2025-04-25T14:52:29.007000+00:00 97640 switchBeam Beam: B 60790.619790139 2025-04-25T14:52:29.868000+00:00 97641 Lock_to_C124421 t_probe [us] = 50000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1041, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 520, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 19.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.623865567 2025-04-25T14:58:21.985000+00:00 97643 SetAtt att_RCDAT : 0.0 dB 60790.623966655 2025-04-25T14:58:30.719000+00:00 97644 StateMachineSupervisor Start Clockrun 60790.623989792 2025-04-25T14:58:32.718000+00:00 97646 switchBeam Beam: B 60790.623999560 2025-04-25T14:58:33.562000+00:00 97647 Lock_to_C124421 t_probe [us] = 700, n_shots = 1, g1 = 0.0, T_drift_s = 600.0, N_drift = 3303, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 1651, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 0.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.626313912 2025-04-25T15:01:53.522000+00:00 97649 StateMachineSupervisor Start Clockrun 60790.626337118 2025-04-25T15:01:55.527000+00:00 97651 switchBeam Beam: B 60790.626346887 2025-04-25T15:01:56.371000+00:00 97652 Lock_to_C124421 t_probe [us] = 700, n_shots = 1, g1 = 0.0, T_drift_s = 600.0, N_drift = 3303, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 1651, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 0.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.629248912 2025-04-25T15:06:07.106000+00:00 97654 SetAtt att_RCDAT : 16.0 dB 60790.629264710 2025-04-25T15:06:08.471000+00:00 97655 StateMachineSupervisor Start Clockrun 60790.629288114 2025-04-25T15:06:10.493000+00:00 97657 switchBeam Beam: B 60790.629297812 2025-04-25T15:06:11.331000+00:00 97658 Lock_to_C124421 t_probe [us] = 25000, n_shots = 1, g1 = 0.0, T_drift_s = 600.0, N_drift = 1593, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 797, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 16.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.629753009 2025-04-25T15:06:50.660000+00:00 97660 StateMachineSupervisor Start Clockrun 60790.629776482 2025-04-25T15:06:52.688000+00:00 97662 switchBeam Beam: B 60790.629786134 2025-04-25T15:06:53.522000+00:00 97663 Lock_to_C124421 t_probe [us] = 25000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1593, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 797, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 16.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.632215752 2025-04-25T15:10:23.441000+00:00 97665 SetLockFreqs Linecenter [MHz AOM]: 75.559510, abs(B) [uT]: 4.798600000, EQS C1, C2, C4 [Hz]: 0.0, 0.0, 0.0 60790.632232824 2025-04-25T15:10:24.916000+00:00 97666 StateMachineSupervisor Start Clockrun 60790.632256285 2025-04-25T15:10:26.943000+00:00 97668 switchBeam Beam: B 60790.632266134 2025-04-25T15:10:27.794000+00:00 97669 Lock_to_C124421 t_probe [us] = 25000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1593, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 797, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 16.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.633315405 2025-04-25T15:11:58.451000+00:00 97671 SetAtt att_RCDAT : 19.0 dB 60790.633332280 2025-04-25T15:11:59.909000+00:00 97672 StateMachineSupervisor Start Clockrun 60790.633355880 2025-04-25T15:12:01.948000+00:00 97674 switchBeam Beam: B 60790.633365891 2025-04-25T15:12:02.813000+00:00 97675 Lock_to_C124421 t_probe [us] = 50000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1041, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 520, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 19.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.635321528 2025-04-25T15:14:51.780000+00:00 97677 SetAtt att_RCDAT : 0.0 dB 60790.638411435 2025-04-25T15:19:18.748000+00:00 97678 RabiFlopping freq_mode C1+ ,sideband_mode Carrier,start_delay 100.0, 60790.641442303 2025-04-25T15:23:40.615000+00:00 97679 RabiFlopping freq_mode C1+ ,sideband_mode +X,start_delay 100.0, 60790.644472627 2025-04-25T15:28:02.435000+00:00 97680 RabiFlopping freq_mode C1+ ,sideband_mode -X,start_delay 100.0, 60790.647503067 2025-04-25T15:32:24.265000+00:00 97681 RabiFlopping freq_mode C1+ ,sideband_mode +Y,start_delay 100.0, 60790.650533472 2025-04-25T15:36:46.092000+00:00 97682 RabiFlopping freq_mode C1+ ,sideband_mode -Y,start_delay 100.0, 60790.653563634 2025-04-25T15:41:07.898000+00:00 97683 RabiFlopping freq_mode C1+ ,sideband_mode +Z,start_delay 100.0, 60790.656593079 2025-04-25T15:45:29.642000+00:00 97684 RabiFlopping freq_mode C1+ ,sideband_mode -Z,start_delay 100.0, 60790.657598136 2025-04-25T15:46:56.479000+00:00 97685 SetAtt att_RCDAT : 19.0 dB 60790.657624166 2025-04-25T15:46:58.728000+00:00 97686 StateMachineSupervisor Start Clockrun 60790.657647720 2025-04-25T15:47:00.763000+00:00 97688 switchBeam Beam: B 60790.657657419 2025-04-25T15:47:01.601000+00:00 97689 Lock_to_C124421 t_probe [us] = 50000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1041, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 520, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 19.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.659284850 2025-04-25T15:49:22.211000+00:00 97691 SetAtt att_RCDAT : 22.0 dB 60790.659301250 2025-04-25T15:49:23.628000+00:00 97692 StateMachineSupervisor Start Clockrun 60790.659324456 2025-04-25T15:49:25.633000+00:00 97694 switchBeam Beam: B 60790.659334201 2025-04-25T15:49:26.475000+00:00 97695 Lock_to_C124421 t_probe [us] = 100000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 612, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 307, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 22.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.671965220 2025-04-25T16:07:37.795000+00:00 97697 StateMachineSupervisor Start Clockrun 60790.671988449 2025-04-25T16:07:39.802000+00:00 97699 switchBeam Beam: B 60790.671997651 2025-04-25T16:07:40.597000+00:00 97700 Lock_to_C124421 t_probe [us] = 103000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 600, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 300, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 22.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, 60790.672440695 2025-04-25T16:08:18.876000+00:00 97701 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60790.672545752 2025-04-25T16:08:27.953000+00:00 97704 MeasureFluorescenceLevels Bright : 39.2 +- 6.3, Dark : 0.1 +- 0.5, Threshold: int( ceil( 2.0 ) ) = 2, N_meas = 50, t_gate = 5.0 ms 60790.672656342 2025-04-25T16:08:37.508000+00:00 97705 SetCoolingAOM mode : umotion, AOM_f (MHz) : 207.5, ATT_Main (dB) = 6.0, ATT_SP (dB) = 17.0. 60790.673617349 2025-04-25T16:10:00.539000+00:00 97706 MicroMotionMeasurement3Beam Beam: B, N_photons: 400000, N_bins: 25, f_mod [MHz]: 14.362000, duration [s]: 60.391 60790.673629190 2025-04-25T16:10:01.562000+00:00 97707 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60790.673638496 2025-04-25T16:10:02.366000+00:00 97708 switchBeam Beam: B 60790.673654502 2025-04-25T16:10:03.749000+00:00 97709 MeasureFluorescenceLevels Bright : 40.7 +- 5.9, Dark : 0.1 +- 0.3, Threshold: int( ceil( 1.8 ) ) = 2, N_meas = 50, t_gate = 5.0 ms 60790.679383900 2025-04-25T16:18:18.769000+00:00 97710 StateMachineSupervisor Start Clockrun 60790.679407164 2025-04-25T16:18:20.779000+00:00 97712 switchBeam Beam: B 60790.679416609 2025-04-25T16:18:21.595000+00:00 97713 Lock_to_C124421 t_probe [us] = 103000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 600, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 300, (C1, C2, C4) att [dB] = (15.00, 15.88, 15.53), att_RCDAT [dB] = 22.00, LCplus [V] = 1.8299, LCminus [V] = 3.2816, # End of file 60790_artiq_log.txt