# Start of file 60748_artiq_log.txt # First point: 60748.364862 2025-03-14T08:45:24.104000+00:00 # Last point: 60748.949517 2025-03-14T22:47:18.276000+00:00 # Num rows: 65 # File updated: 2025-03-15T01:10:50.030588 # Columns: MJD DATE RID PROGRAM MESSAGE 60748.364862315 2025-03-14T08:45:24.104000+00:00 83157 CoolingDetuningScan From [AOM MHz]: 180.000, To [AOM MHz]: 220.000, num_pts: 100, t_gate (ms) = 100.0 60748.365149988 2025-03-14T08:45:48.959000+00:00 83158 StateMachineSupervisor Start Clockrun 60748.365173623 2025-03-14T08:45:51.001000+00:00 83160 switchBeam Beam: B 60748.365184329 2025-03-14T08:45:51.926000+00:00 83161 Lock_to_C124421 t_probe [us] = 113000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 555, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 277, (C1, C2, C4) att [dB] = (15.00, 16.20, 16.00), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8387, LCminus [V] = 3.2587, 60748.465150949 2025-03-14T11:09:49.042000+00:00 83158 StateMachineSupervisor Ion Dark 60748.465157049 2025-03-14T11:09:49.569000+00:00 83158 StateMachineSupervisor Recover Ion 60748.465167361 2025-03-14T11:09:50.460000+00:00 83162 switchBeam Beam: ABC 60748.465199780 2025-03-14T11:09:53.261000+00:00 83165 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60748.465297407 2025-03-14T11:10:01.696000+00:00 83166 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60748.465316378 2025-03-14T11:10:03.335000+00:00 83168 switchBeam Beam: B 60748.465338970 2025-03-14T11:10:05.287000+00:00 83169 MeasureFluorescenceLevels Bright : 49.0 +- 8.0, Dark : 0.2 +- 0.6, Threshold: int( ceil( 2.8 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60748.465349363 2025-03-14T11:10:06.185000+00:00 83158 StateMachineSupervisor Ion Bright, Start Clockrun 60748.465383704 2025-03-14T11:10:09.152000+00:00 83172 switchBeam Beam: B 60748.465393819 2025-03-14T11:10:10.026000+00:00 83173 Lock_to_C124421 t_probe [us] = 113000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 555, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 277, (C1, C2, C4) att [dB] = (15.00, 16.20, 16.00), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8387, LCminus [V] = 3.2587, 60748.514365579 2025-03-14T12:20:41.186000+00:00 83158 StateMachineSupervisor Ion Dark 60748.514371620 2025-03-14T12:20:41.708000+00:00 83158 StateMachineSupervisor Recover Ion 60748.514381597 2025-03-14T12:20:42.570000+00:00 83174 switchBeam Beam: ABC 60748.514415139 2025-03-14T12:20:45.468000+00:00 83177 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60748.514513009 2025-03-14T12:20:53.924000+00:00 83178 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60748.514533889 2025-03-14T12:20:55.728000+00:00 83180 switchBeam Beam: B 60748.514556227 2025-03-14T12:20:57.658000+00:00 83181 MeasureFluorescenceLevels Bright : 49.2 +- 7.9, Dark : 0.1 +- 0.4, Threshold: int( ceil( 2.5 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60748.514569884 2025-03-14T12:20:58.838000+00:00 83158 StateMachineSupervisor Ion Bright, Start Clockrun 60748.514604641 2025-03-14T12:21:01.841000+00:00 83184 switchBeam Beam: B 60748.514614977 2025-03-14T12:21:02.734000+00:00 83185 Lock_to_C124421 t_probe [us] = 113000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 555, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 277, (C1, C2, C4) att [dB] = (15.00, 16.20, 16.00), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8387, LCminus [V] = 3.2587, 60748.519371435 2025-03-14T12:27:53.692000+00:00 83187 SecularXYZ3 N_photons: 3000, num_pts: 101, TicklerAtt (attX, attY, attZ) [dB]: (19.0, 15.0, 30.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.935000, 0.209756, 15.051538, 95.577559) 60748.522512835 2025-03-14T12:32:25.109000+00:00 83188 SecularXYZ3 N_photons: 3000, num_pts: 101, TicklerAtt (attX, attY, attZ) [dB]: (19.0, 15.0, 30.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.935000, 0.209756, 15.051538, 95.577559) 60748.524975312 2025-03-14T12:35:57.867000+00:00 83189 SecularXYZ3 N_photons: 3000, num_pts: 101, TicklerAtt (attX, attY, attZ) [dB]: (19.0, 15.0, 30.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.935000, 0.209756, 15.051538, 95.577559) 60748.528849028 2025-03-14T12:41:32.556000+00:00 83190 SecularXYZ3 N_photons: 3000, num_pts: 101, TicklerAtt (attX, attY, attZ) [dB]: (19.0, 15.0, 30.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.935000, 0.209756, 15.051538, 95.577559) 60748.530931447 2025-03-14T12:44:32.477000+00:00 83191 SecularXYZ3 N_photons: 3000, num_pts: 101, TicklerAtt (attX, attY, attZ) [dB]: (19.0, 15.0, 30.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.935000, 0.209756, 15.051538, 95.577559) 60748.535020833 2025-03-14T12:50:25.800000+00:00 83192 SecularXYZ3 N_photons: 3000, num_pts: 101, TicklerAtt (attX, attY, attZ) [dB]: (19.0, 15.0, 30.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.935000, 0.209756, 15.051538, 95.577559) 60748.540068518 2025-03-14T12:57:41.920000+00:00 83193 MeasureFluorescenceLevels Bright : 47.6 +- 6.8, Dark : 0.2 +- 0.4, Threshold: int( ceil( 2.8 ) ) = 3, N_meas = 50, t_gate = 5.0 ms 60748.541800104 2025-03-14T13:00:11.529000+00:00 83194 SecularXYZ3 N_photons: 3000, num_pts: 101, TicklerAtt (attX, attY, attZ) [dB]: (19.0, 15.0, 30.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.935000, 0.209756, 15.051538, 95.577559) 60748.544234178 2025-03-14T13:03:41.833000+00:00 83195 StateMachineSupervisor Start Clockrun 60748.544257998 2025-03-14T13:03:43.891000+00:00 83197 switchBeam Beam: B 60748.544268160 2025-03-14T13:03:44.769000+00:00 83198 Lock_to_C124421 t_probe [us] = 113000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 555, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 277, (C1, C2, C4) att [dB] = (15.00, 16.20, 16.00), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8387, LCminus [V] = 3.2587, 60748.691283183 2025-03-14T16:35:26.867000+00:00 83195 StateMachineSupervisor Ion Dark 60748.691289306 2025-03-14T16:35:27.396000+00:00 83195 StateMachineSupervisor Recover Ion 60748.691298750 2025-03-14T16:35:28.212000+00:00 83199 switchBeam Beam: ABC 60748.691330845 2025-03-14T16:35:30.985000+00:00 83202 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60748.691429502 2025-03-14T16:35:39.509000+00:00 83203 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60748.691449317 2025-03-14T16:35:41.221000+00:00 83205 switchBeam Beam: B 60748.691471771 2025-03-14T16:35:43.161000+00:00 83206 MeasureFluorescenceLevels Bright : 49.4 +- 7.6, Dark : 0.1 +- 0.3, Threshold: int( ceil( 2.1 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60748.691481540 2025-03-14T16:35:44.005000+00:00 83195 StateMachineSupervisor Ion Bright, Start Clockrun 60748.691514595 2025-03-14T16:35:46.861000+00:00 83209 switchBeam Beam: B 60748.691524433 2025-03-14T16:35:47.711000+00:00 83210 Lock_to_C124421 t_probe [us] = 113000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 555, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 277, (C1, C2, C4) att [dB] = (15.00, 16.20, 16.00), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8387, LCminus [V] = 3.2587, 60748.800521424 2025-03-14T19:12:45.051000+00:00 83195 StateMachineSupervisor Ion Dark 60748.800527500 2025-03-14T19:12:45.576000+00:00 83195 StateMachineSupervisor Recover Ion 60748.800537176 2025-03-14T19:12:46.412000+00:00 83211 switchBeam Beam: ABC 60748.800569387 2025-03-14T19:12:49.195000+00:00 83214 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60748.800667697 2025-03-14T19:12:57.689000+00:00 83215 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60748.800686979 2025-03-14T19:12:59.355000+00:00 83217 switchBeam Beam: B 60748.800709062 2025-03-14T19:13:01.263000+00:00 83218 MeasureFluorescenceLevels Bright : 49.1 +- 6.9, Dark : 0.1 +- 0.4, Threshold: int( ceil( 2.1 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60748.800719699 2025-03-14T19:13:02.182000+00:00 83195 StateMachineSupervisor Ion Bright, Start Clockrun 60748.800753194 2025-03-14T19:13:05.076000+00:00 83221 switchBeam Beam: B 60748.800762789 2025-03-14T19:13:05.905000+00:00 83222 Lock_to_C124421 t_probe [us] = 113000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 555, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 277, (C1, C2, C4) att [dB] = (15.00, 16.20, 16.00), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8387, LCminus [V] = 3.2587, 60748.949274236 2025-03-14T22:46:57.294000+00:00 83195 StateMachineSupervisor Ion Dark 60748.949280382 2025-03-14T22:46:57.825000+00:00 83195 StateMachineSupervisor Recover Ion 60748.949289757 2025-03-14T22:46:58.635000+00:00 83223 switchBeam Beam: ABC 60748.949321481 2025-03-14T22:47:01.376000+00:00 83226 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60748.949420382 2025-03-14T22:47:09.921000+00:00 83227 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60748.949440139 2025-03-14T22:47:11.628000+00:00 83229 switchBeam Beam: B 60748.949462280 2025-03-14T22:47:13.541000+00:00 83230 MeasureFluorescenceLevels Bright : 47.6 +- 7.1, Dark : 0.1 +- 0.4, Threshold: int( ceil( 2.2 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60748.949472778 2025-03-14T22:47:14.448000+00:00 83195 StateMachineSupervisor Ion Bright, Start Clockrun 60748.949507210 2025-03-14T22:47:17.423000+00:00 83233 switchBeam Beam: B 60748.949517083 2025-03-14T22:47:18.276000+00:00 83234 Lock_to_C124421 t_probe [us] = 113000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 555, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 277, (C1, C2, C4) att [dB] = (15.00, 16.20, 16.00), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8387, LCminus [V] = 3.2587, # End of file 60748_artiq_log.txt