# Start of file 60710_artiq_log.txt # First point: 60710.082249 2025-02-04T01:58:26.290000+00:00 # Last point: 60710.927223 2025-02-04T22:15:12.105000+00:00 # Num rows: 33 # File updated: 2025-02-05T08:20:39.421135 # Columns: MJD DATE RID PROGRAM MESSAGE 60710.082248727 2025-02-04T01:58:26.290000+00:00 80006 StateMachineSupervisor Ion Dark 60710.082254838 2025-02-04T01:58:26.818000+00:00 80006 StateMachineSupervisor Recover Ion 60710.082268542 2025-02-04T01:58:28.002000+00:00 80010 switchBeam Beam: ABC 60710.082302338 2025-02-04T01:58:30.922000+00:00 80013 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60710.082396250 2025-02-04T01:58:39.036000+00:00 80014 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60710.082414977 2025-02-04T01:58:40.654000+00:00 80016 switchBeam Beam: B 60710.082439548 2025-02-04T01:58:42.777000+00:00 80017 MeasureFluorescenceLevels Bright : 62.1 +- 7.9, Dark : 0.9 +- 0.9, Threshold: int( ceil( 7.7 ) ) = 8, N_meas = 100, t_gate = 5.0 ms 60710.082452917 2025-02-04T01:58:43.932000+00:00 80006 StateMachineSupervisor Ion Bright, Start Clockrun 60710.082487974 2025-02-04T01:58:46.961000+00:00 80020 switchBeam Beam: B 60710.082500625 2025-02-04T01:58:48.054000+00:00 80021 Lock_to_C124421 t_probe [us] = 128000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 498, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 250, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8299, LCminus [V] = 3.2473, 60710.650979815 2025-02-04T15:37:24.656000+00:00 80023 StateMachineSupervisor Start Clockrun 60710.651006215 2025-02-04T15:37:26.937000+00:00 80025 switchBeam Beam: B 60710.651016157 2025-02-04T15:37:27.796000+00:00 80026 Lock_to_C124421 t_probe [us] = 128000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 498, pmt_thr = 13, T_p0avg_s = 900.0, N_p0avg = 250, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8299, LCminus [V] = 3.2473, 60710.918768646 2025-02-04T22:03:01.611000+00:00 80023 StateMachineSupervisor Ion Dark 60710.918774769 2025-02-04T22:03:02.140000+00:00 80023 StateMachineSupervisor Recover Ion 60710.918786841 2025-02-04T22:03:03.183000+00:00 80027 switchBeam Beam: ABC 60710.918824306 2025-02-04T22:03:06.420000+00:00 80030 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60710.918916389 2025-02-04T22:03:14.376000+00:00 80031 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60710.918939803 2025-02-04T22:03:16.399000+00:00 80033 switchBeam Beam: B 60710.918961921 2025-02-04T22:03:18.310000+00:00 80034 MeasureFluorescenceLevels Bright : 62.1 +- 7.7, Dark : 1.1 +- 1.1, Threshold: int( ceil( 8.4 ) ) = 9, N_meas = 100, t_gate = 5.0 ms 60710.918972836 2025-02-04T22:03:19.253000+00:00 80023 StateMachineSupervisor Ion Bright, Start Clockrun 60710.919011817 2025-02-04T22:03:22.621000+00:00 80037 switchBeam Beam: B 60710.919021840 2025-02-04T22:03:23.487000+00:00 80038 Lock_to_C124421 t_probe [us] = 128000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 498, pmt_thr = 13, T_p0avg_s = 900.0, N_p0avg = 250, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8299, LCminus [V] = 3.2473, 60710.926968495 2025-02-04T22:14:50.078000+00:00 80023 StateMachineSupervisor Ion Dark 60710.926974548 2025-02-04T22:14:50.601000+00:00 80023 StateMachineSupervisor Recover Ion 60710.926986319 2025-02-04T22:14:51.618000+00:00 80039 switchBeam Beam: ABC 60710.927021470 2025-02-04T22:14:54.655000+00:00 80042 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60710.927116620 2025-02-04T22:15:02.876000+00:00 80043 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60710.927137720 2025-02-04T22:15:04.699000+00:00 80045 switchBeam Beam: B 60710.927163159 2025-02-04T22:15:06.897000+00:00 80046 MeasureFluorescenceLevels Bright : 62.6 +- 7.9, Dark : 1.0 +- 1.0, Threshold: int( ceil( 8.1 ) ) = 9, N_meas = 100, t_gate = 5.0 ms 60710.927172604 2025-02-04T22:15:07.713000+00:00 80023 StateMachineSupervisor Ion Bright, Start Clockrun 60710.927213877 2025-02-04T22:15:11.279000+00:00 80049 switchBeam Beam: B 60710.927223437 2025-02-04T22:15:12.105000+00:00 80050 Lock_to_C124421 t_probe [us] = 128000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 498, pmt_thr = 13, T_p0avg_s = 900.0, N_p0avg = 250, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8299, LCminus [V] = 3.2473, # End of file 60710_artiq_log.txt