# Start of file 60679_artiq_log.txt # First point: 60679.215292 2025-01-04T05:10:01.243000+00:00 # Last point: 60679.639185 2025-01-04T15:20:25.600000+00:00 # Num rows: 50 # File updated: 2025-01-05T01:10:46.047624 # Columns: MJD DATE RID PROGRAM MESSAGE 60679.215292164 2025-01-04T05:10:01.243000+00:00 72705 StateMachineSupervisor Ion Dark 60679.215298194 2025-01-04T05:10:01.764000+00:00 72705 StateMachineSupervisor Recover Ion 60679.215307732 2025-01-04T05:10:02.588000+00:00 72793 switchBeam Beam: ABC 60679.215338669 2025-01-04T05:10:05.261000+00:00 72796 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60679.215437755 2025-01-04T05:10:13.822000+00:00 72797 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60679.215456354 2025-01-04T05:10:15.429000+00:00 72799 switchBeam Beam: B 60679.215478102 2025-01-04T05:10:17.308000+00:00 72800 MeasureFluorescenceLevels Bright : 60.8 +- 9.0, Dark : 1.0 +- 1.0, Threshold: int( ceil( 7.7 ) ) = 8, N_meas = 100, t_gate = 5.0 ms 60679.215490417 2025-01-04T05:10:18.372000+00:00 72705 StateMachineSupervisor Ion Bright, Start Clockrun 60679.215523345 2025-01-04T05:10:21.217000+00:00 72803 switchBeam Beam: B 60679.215533646 2025-01-04T05:10:22.107000+00:00 72804 Lock_to_C124421 t_probe [us] = 124000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 513, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 256, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8435, LCminus [V] = 3.2930, 60679.223718171 2025-01-04T05:22:09.250000+00:00 72705 StateMachineSupervisor Ion Dark 60679.223724317 2025-01-04T05:22:09.781000+00:00 72705 StateMachineSupervisor Recover Ion 60679.223733414 2025-01-04T05:22:10.567000+00:00 72805 switchBeam Beam: ABC 60679.223764688 2025-01-04T05:22:13.269000+00:00 72808 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60679.223864155 2025-01-04T05:22:21.863000+00:00 72809 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60679.223883415 2025-01-04T05:22:23.527000+00:00 72811 switchBeam Beam: B 60679.223905984 2025-01-04T05:22:25.477000+00:00 72812 MeasureFluorescenceLevels Bright : 60.8 +- 8.3, Dark : 1.0 +- 1.1, Threshold: int( ceil( 7.8 ) ) = 8, N_meas = 100, t_gate = 5.0 ms 60679.223916505 2025-01-04T05:22:26.386000+00:00 72705 StateMachineSupervisor Ion Bright, Start Clockrun 60679.223949375 2025-01-04T05:22:29.226000+00:00 72815 switchBeam Beam: B 60679.223958842 2025-01-04T05:22:30.044000+00:00 72816 Lock_to_C124421 t_probe [us] = 124000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 513, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 256, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8435, LCminus [V] = 3.2930, 60679.306077685 2025-01-04T07:20:45.112000+00:00 72705 StateMachineSupervisor Ion Dark 60679.306083703 2025-01-04T07:20:45.632000+00:00 72705 StateMachineSupervisor Recover Ion 60679.306093843 2025-01-04T07:20:46.508000+00:00 72817 switchBeam Beam: ABC 60679.306125162 2025-01-04T07:20:49.214000+00:00 72820 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60679.306223541 2025-01-04T07:20:57.714000+00:00 72821 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60679.306242280 2025-01-04T07:20:59.333000+00:00 72823 switchBeam Beam: B 60679.306264271 2025-01-04T07:21:01.233000+00:00 72824 MeasureFluorescenceLevels Bright : 60.1 +- 7.5, Dark : 0.9 +- 0.9, Threshold: int( ceil( 7.3 ) ) = 8, N_meas = 100, t_gate = 5.0 ms 60679.306276065 2025-01-04T07:21:02.252000+00:00 72705 StateMachineSupervisor Ion Bright, Start Clockrun 60679.306308762 2025-01-04T07:21:05.077000+00:00 72827 switchBeam Beam: B 60679.306318137 2025-01-04T07:21:05.887000+00:00 72828 Lock_to_C124421 t_probe [us] = 124000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 513, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 256, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8435, LCminus [V] = 3.2930, 60679.402575509 2025-01-04T09:39:42.524000+00:00 72705 StateMachineSupervisor Ion Dark 60679.402581678 2025-01-04T09:39:43.057000+00:00 72705 StateMachineSupervisor Recover Ion 60679.402590753 2025-01-04T09:39:43.841000+00:00 72829 switchBeam Beam: ABC 60679.402621829 2025-01-04T09:39:46.526000+00:00 72832 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60679.402721956 2025-01-04T09:39:55.177000+00:00 72833 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60679.402741331 2025-01-04T09:39:56.851000+00:00 72835 switchBeam Beam: B 60679.402763403 2025-01-04T09:39:58.758000+00:00 72836 MeasureFluorescenceLevels Bright : 61.9 +- 7.9, Dark : 0.9 +- 1.0, Threshold: int( ceil( 7.6 ) ) = 8, N_meas = 100, t_gate = 5.0 ms 60679.402773981 2025-01-04T09:39:59.672000+00:00 72705 StateMachineSupervisor Ion Bright, Start Clockrun 60679.402806771 2025-01-04T09:40:02.505000+00:00 72839 switchBeam Beam: B 60679.402816065 2025-01-04T09:40:03.308000+00:00 72840 Lock_to_C124421 t_probe [us] = 124000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 513, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 256, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8435, LCminus [V] = 3.2930, 60679.638943877 2025-01-04T15:20:04.751000+00:00 72705 StateMachineSupervisor Ion Dark 60679.638949919 2025-01-04T15:20:05.273000+00:00 72705 StateMachineSupervisor Recover Ion 60679.638959178 2025-01-04T15:20:06.073000+00:00 72841 switchBeam Beam: ABC 60679.638990243 2025-01-04T15:20:08.757000+00:00 72844 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60679.639089491 2025-01-04T15:20:17.332000+00:00 72845 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60679.639108784 2025-01-04T15:20:18.999000+00:00 72847 switchBeam Beam: B 60679.639130937 2025-01-04T15:20:20.913000+00:00 72848 MeasureFluorescenceLevels Bright : 62.6 +- 8.1, Dark : 0.9 +- 1.1, Threshold: int( ceil( 7.3 ) ) = 8, N_meas = 100, t_gate = 5.0 ms 60679.639142072 2025-01-04T15:20:21.875000+00:00 72705 StateMachineSupervisor Ion Bright, Start Clockrun 60679.639175799 2025-01-04T15:20:24.789000+00:00 72851 switchBeam Beam: B 60679.639185185 2025-01-04T15:20:25.600000+00:00 72852 Lock_to_C124421 t_probe [us] = 124000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 513, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 256, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8435, LCminus [V] = 3.2930, # End of file 60679_artiq_log.txt