# Start of file 60668_artiq_log.txt # First point: 60668.697776 2024-12-24T16:44:47.819000+00:00 # Last point: 60668.884088 2024-12-24T21:13:05.174000+00:00 # Num rows: 20 # File updated: 2024-12-25T01:10:47.977785 # Columns: MJD DATE RID PROGRAM MESSAGE 60668.697775683 2024-12-24T16:44:47.819000+00:00 72464 StateMachineSupervisor Ion Dark 60668.697781829 2024-12-24T16:44:48.350000+00:00 72464 StateMachineSupervisor Recover Ion 60668.697791285 2024-12-24T16:44:49.167000+00:00 72480 switchBeam Beam: ABC 60668.697822986 2024-12-24T16:44:51.906000+00:00 72483 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60668.697921701 2024-12-24T16:45:00.435000+00:00 72484 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60668.697940590 2024-12-24T16:45:02.067000+00:00 72486 switchBeam Beam: B 60668.697963981 2024-12-24T16:45:04.088000+00:00 72487 MeasureFluorescenceLevels Bright : 60.0 +- 7.4, Dark : 1.0 +- 1.0, Threshold: int( ceil( 7.8 ) ) = 8, N_meas = 100, t_gate = 5.0 ms 60668.697974132 2024-12-24T16:45:04.965000+00:00 72464 StateMachineSupervisor Ion Bright, Start Clockrun 60668.698007720 2024-12-24T16:45:07.867000+00:00 72490 switchBeam Beam: B 60668.698017616 2024-12-24T16:45:08.722000+00:00 72491 Lock_to_C124421 t_probe [us] = 124000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 513, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 256, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8435, LCminus [V] = 3.2930, 60668.883846713 2024-12-24T21:12:44.356000+00:00 72464 StateMachineSupervisor Ion Dark 60668.883852859 2024-12-24T21:12:44.887000+00:00 72464 StateMachineSupervisor Recover Ion 60668.883862199 2024-12-24T21:12:45.694000+00:00 72492 switchBeam Beam: ABC 60668.883893901 2024-12-24T21:12:48.433000+00:00 72495 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60668.883992639 2024-12-24T21:12:56.964000+00:00 72496 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 15.0, ATT_SP (dB) = 20.0. 60668.884011273 2024-12-24T21:12:58.574000+00:00 72498 switchBeam Beam: B 60668.884033044 2024-12-24T21:13:00.455000+00:00 72499 MeasureFluorescenceLevels Bright : 60.6 +- 7.9, Dark : 1.0 +- 1.0, Threshold: int( ceil( 7.7 ) ) = 8, N_meas = 100, t_gate = 5.0 ms 60668.884045151 2024-12-24T21:13:01.501000+00:00 72464 StateMachineSupervisor Ion Bright, Start Clockrun 60668.884078067 2024-12-24T21:13:04.345000+00:00 72502 switchBeam Beam: B 60668.884087662 2024-12-24T21:13:05.174000+00:00 72503 Lock_to_C124421 t_probe [us] = 124000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 513, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 256, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8435, LCminus [V] = 3.2930, # End of file 60668_artiq_log.txt