# Start of file 60629_artiq_log.txt # First point: 60629.066048 2024-11-15T01:35:06.548000+00:00 # Last point: 60629.743352 2024-11-15T17:50:25.645000+00:00 # Num rows: 77 # File updated: 2024-11-16T01:10:37.043313 # Columns: MJD DATE RID PROGRAM MESSAGE 60629.066048009 2024-11-15T01:35:06.548000+00:00 65070 StateMachineSupervisor Ion Dark 60629.066054051 2024-11-15T01:35:07.070000+00:00 65070 StateMachineSupervisor Recover Ion 60629.066064074 2024-11-15T01:35:07.936000+00:00 65086 switchBeam Beam: ABC 60629.066095718 2024-11-15T01:35:10.670000+00:00 65089 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60629.066194201 2024-11-15T01:35:19.179000+00:00 65090 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 10.0, ATT_SP (dB) = 23.0. 60629.066213599 2024-11-15T01:35:20.855000+00:00 65092 switchBeam Beam: B 60629.066236111 2024-11-15T01:35:22.800000+00:00 65093 MeasureFluorescenceLevels Bright : 94.2 +- 10.5, Dark : 1.1 +- 1.0, Threshold: int( ceil( 10.3 ) ) = 11, N_meas = 100, t_gate = 5.0 ms 60629.066246239 2024-11-15T01:35:23.675000+00:00 65070 StateMachineSupervisor Ion Bright, Start Clockrun 60629.066279317 2024-11-15T01:35:26.533000+00:00 65096 switchBeam Beam: B 60629.066288681 2024-11-15T01:35:27.342000+00:00 65097 Lock_to_C124421 t_probe [us] = 96000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 633, pmt_thr = 16, T_p0avg_s = 900.0, N_p0avg = 317, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 23.00, LCplus [V] = 1.8499, LCminus [V] = 3.3234, 60629.223961875 2024-11-15T05:22:30.306000+00:00 65099 SetCoolingAOM mode : umotion, AOM_f (MHz) : 207.5, ATT_Main (dB) = 6.0, ATT_SP (dB) = 17.0. 60629.224735116 2024-11-15T05:23:37.114000+00:00 65100 MicroMotionMeasurement3Beam Beam: B, N_photons: 200000, N_bins: 25, f_mod [MHz]: 14.418000, duration [s]: 41.098 60629.224961760 2024-11-15T05:23:56.696000+00:00 65101 MicroMotionMinimizerBrent2 N_photons: 200000, Initial (V12cm, V12diff, V34cm, V34diff) [V]: (-5.944700, 0.225253, 16.085888, 91.085837), num_iterations: 6, 60629.225886042 2024-11-15T05:25:16.554000+00:00 65102 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 20.0. 60629.225919271 2024-11-15T05:25:19.425000+00:00 65103 switchBeam Beam: B 60629.226084132 2024-11-15T05:25:33.669000+00:00 65104 StateMachineSupervisor Start Clockrun 60629.226107975 2024-11-15T05:25:35.729000+00:00 65106 switchBeam Beam: B 60629.226117338 2024-11-15T05:25:36.538000+00:00 65107 Lock_to_C124421 t_probe [us] = 96000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 633, pmt_thr = 16, T_p0avg_s = 900.0, N_p0avg = 317, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 23.00, LCplus [V] = 1.8499, LCminus [V] = 3.3234, 60629.228925069 2024-11-15T05:29:39.126000+00:00 65109 MeasureFluorescenceLevels Bright : 57.4 +- 7.4, Dark : 0.6 +- 0.7, Threshold: int( ceil( 6.0 ) ) = 6, N_meas = 50, t_gate = 5.0 ms 60629.230132350 2024-11-15T05:31:23.435000+00:00 65110 MeasureFluorescenceLevels Bright : 59.1 +- 8.1, Dark : 0.7 +- 1.1, Threshold: int( ceil( 6.6 ) ) = 7, N_meas = 50, t_gate = 5.0 ms 60629.230179606 2024-11-15T05:31:27.518000+00:00 65111 StateMachineSupervisor Start Clockrun 60629.230203438 2024-11-15T05:31:29.577000+00:00 65113 switchBeam Beam: B 60629.230212940 2024-11-15T05:31:30.398000+00:00 65114 Lock_to_C124421 t_probe [us] = 96000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 633, pmt_thr = 16, T_p0avg_s = 900.0, N_p0avg = 317, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 23.00, LCplus [V] = 1.8499, LCminus [V] = 3.3234, 60629.310601423 2024-11-15T07:27:15.963000+00:00 65111 StateMachineSupervisor Ion Dark 60629.310607546 2024-11-15T07:27:16.492000+00:00 65111 StateMachineSupervisor Recover Ion 60629.310616863 2024-11-15T07:27:17.297000+00:00 65115 switchBeam Beam: ABC 60629.310650081 2024-11-15T07:27:20.167000+00:00 65118 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60629.310747685 2024-11-15T07:27:28.600000+00:00 65119 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 10.0, ATT_SP (dB) = 23.0. 60629.310766829 2024-11-15T07:27:30.254000+00:00 65121 switchBeam Beam: B 60629.310788553 2024-11-15T07:27:32.131000+00:00 65122 MeasureFluorescenceLevels Bright : 96.7 +- 9.7, Dark : 1.4 +- 1.2, Threshold: int( ceil( 11.5 ) ) = 12, N_meas = 100, t_gate = 5.0 ms 60629.310799838 2024-11-15T07:27:33.106000+00:00 65111 StateMachineSupervisor Ion Bright, Start Clockrun 60629.310833171 2024-11-15T07:27:35.986000+00:00 65125 switchBeam Beam: B 60629.310842546 2024-11-15T07:27:36.796000+00:00 65126 Lock_to_C124421 t_probe [us] = 96000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 633, pmt_thr = 16, T_p0avg_s = 900.0, N_p0avg = 317, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 23.00, LCplus [V] = 1.8499, LCminus [V] = 3.3234, 60629.402786077 2024-11-15T09:40:00.717000+00:00 65128 MeasureFluorescenceLevels Bright : 59.0 +- 6.6, Dark : 0.6 +- 1.1, Threshold: int( ceil( 6.1 ) ) = 7, N_meas = 50, t_gate = 5.0 ms 60629.402828669 2024-11-15T09:40:04.397000+00:00 65129 StateMachineSupervisor Start Clockrun 60629.402853079 2024-11-15T09:40:06.506000+00:00 65131 switchBeam Beam: B 60629.402863148 2024-11-15T09:40:07.376000+00:00 65132 Lock_to_C124421 t_probe [us] = 96000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 633, pmt_thr = 16, T_p0avg_s = 900.0, N_p0avg = 317, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 23.00, LCplus [V] = 1.8499, LCminus [V] = 3.3234, 60629.486763032 2024-11-15T11:40:56.326000+00:00 65134 SetLockFreqs Linecenter [MHz AOM]: 75.565509, abs(B) [uT]: 4.801250000, EQS C1, C2, C4 [Hz]: 0.0, 0.0, 0.0 60629.486822674 2024-11-15T11:41:01.479000+00:00 65135 SetAtt att_RCDAT : 20.0 dB 60629.487044606 2024-11-15T11:41:20.654000+00:00 65136 StateMachineSupervisor Start Clockrun 60629.487068229 2024-11-15T11:41:22.695000+00:00 65138 switchBeam Beam: B 60629.487077813 2024-11-15T11:41:23.523000+00:00 65139 Lock_to_C124421 t_probe [us] = 40000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1209, pmt_thr = 16, T_p0avg_s = 900.0, N_p0avg = 604, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 20.00, LCplus [V] = 1.8499, LCminus [V] = 3.3234, 60629.490202396 2024-11-15T11:45:53.487000+00:00 65141 SetAtt att_RCDAT : 23.0 dB 60629.490249792 2024-11-15T11:45:57.582000+00:00 65142 StateMachineSupervisor Start Clockrun 60629.490273183 2024-11-15T11:45:59.603000+00:00 65144 switchBeam Beam: B 60629.490282986 2024-11-15T11:46:00.450000+00:00 65145 Lock_to_C124421 t_probe [us] = 70000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 813, pmt_thr = 16, T_p0avg_s = 900.0, N_p0avg = 407, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 23.00, LCplus [V] = 1.8499, LCminus [V] = 3.3234, 60629.551550683 2024-11-15T13:14:13.979000+00:00 65142 StateMachineSupervisor Ion Dark 60629.551556806 2024-11-15T13:14:14.508000+00:00 65142 StateMachineSupervisor Recover Ion 60629.551566401 2024-11-15T13:14:15.337000+00:00 65146 switchBeam Beam: ABC 60629.551597963 2024-11-15T13:14:18.064000+00:00 65149 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60629.551696516 2024-11-15T13:14:26.579000+00:00 65150 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 10.0, ATT_SP (dB) = 23.0. 60629.551716667 2024-11-15T13:14:28.320000+00:00 65152 switchBeam Beam: B 60629.551738820 2024-11-15T13:14:30.234000+00:00 65153 MeasureFluorescenceLevels Bright : 100.5 +- 9.2, Dark : 1.6 +- 1.1, Threshold: int( ceil( 12.6 ) ) = 13, N_meas = 100, t_gate = 5.0 ms 60629.551749005 2024-11-15T13:14:31.114000+00:00 65142 StateMachineSupervisor Ion Bright, Start Clockrun 60629.551782153 2024-11-15T13:14:33.978000+00:00 65156 switchBeam Beam: B 60629.551791887 2024-11-15T13:14:34.819000+00:00 65157 Lock_to_C124421 t_probe [us] = 70000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 813, pmt_thr = 16, T_p0avg_s = 900.0, N_p0avg = 407, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 23.00, LCplus [V] = 1.8499, LCminus [V] = 3.3234, 60629.672523357 2024-11-15T16:08:26.018000+00:00 65159 SetCoolingAOM mode : umotion, AOM_f (MHz) : 207.5, ATT_Main (dB) = 6.0, ATT_SP (dB) = 17.0. 60629.672552176 2024-11-15T16:08:28.508000+00:00 65160 SetCoolingAOM mode : umotion, AOM_f (MHz) : 207.5, ATT_Main (dB) = 6.0, ATT_SP (dB) = 17.0. 60629.673152813 2024-11-15T16:09:20.403000+00:00 65161 MicroMotionMeasurement3Beam Beam: B, N_photons: 200000, N_bins: 25, f_mod [MHz]: 14.418000, duration [s]: 37.631 60629.673241308 2024-11-15T16:09:28.049000+00:00 65162 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 20.0. 60629.673262014 2024-11-15T16:09:29.838000+00:00 65163 switchBeam Beam: B 60629.673301030 2024-11-15T16:09:33.209000+00:00 65164 SetAtt att_RCDAT : 20.0 dB 60629.675119248 2024-11-15T16:12:10.303000+00:00 65165 RabiFlopping freq_mode C1+ ,sideband_mode Carrier, 60629.675389861 2024-11-15T16:12:33.684000+00:00 65166 SetAtt att_RCDAT : 23.0 dB 60629.675437662 2024-11-15T16:12:37.814000+00:00 65167 StateMachineSupervisor Start Clockrun 60629.675462014 2024-11-15T16:12:39.918000+00:00 65169 switchBeam Beam: B 60629.675471748 2024-11-15T16:12:40.759000+00:00 65170 Lock_to_C124421 t_probe [us] = 80000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 735, pmt_thr = 16, T_p0avg_s = 900.0, N_p0avg = 367, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 23.00, LCplus [V] = 1.8499, LCminus [V] = 3.3234, 60629.743111794 2024-11-15T17:50:04.859000+00:00 65167 StateMachineSupervisor Ion Dark 60629.743117894 2024-11-15T17:50:05.386000+00:00 65167 StateMachineSupervisor Recover Ion 60629.743127928 2024-11-15T17:50:06.253000+00:00 65171 switchBeam Beam: ABC 60629.743159526 2024-11-15T17:50:08.983000+00:00 65174 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60629.743257489 2024-11-15T17:50:17.447000+00:00 65175 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 10.0, ATT_SP (dB) = 23.0. 60629.743277141 2024-11-15T17:50:19.145000+00:00 65177 switchBeam Beam: B 60629.743299873 2024-11-15T17:50:21.109000+00:00 65178 MeasureFluorescenceLevels Bright : 107.2 +- 9.5, Dark : 1.2 +- 1.3, Threshold: int( ceil( 11.5 ) ) = 12, N_meas = 100, t_gate = 5.0 ms 60629.743310116 2024-11-15T17:50:21.994000+00:00 65167 StateMachineSupervisor Ion Bright, Start Clockrun 60629.743342916 2024-11-15T17:50:24.828000+00:00 65181 switchBeam Beam: B 60629.743352373 2024-11-15T17:50:25.645000+00:00 65182 Lock_to_C124421 t_probe [us] = 80000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 735, pmt_thr = 16, T_p0avg_s = 900.0, N_p0avg = 367, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 23.00, LCplus [V] = 1.8499, LCminus [V] = 3.3234, # End of file 60629_artiq_log.txt