# Start of file 60617_artiq_log.txt # First point: 60617.249939 2024-11-03T05:59:54.765000+00:00 # Last point: 60617.974308 2024-11-03T23:23:00.236000+00:00 # Num rows: 47 # File updated: 2024-11-04T01:10:31.110694 # Columns: MJD DATE RID PROGRAM MESSAGE 60617.249939410 2024-11-03T05:59:54.765000+00:00 62834 SetCoolingAOM mode : umotion, AOM_f (MHz) : 207.5, ATT_Main (dB) = 9.0, ATT_SP (dB) = 19.0. 60617.249999398 2024-11-03T05:59:59.948000+00:00 62835 MicroMotionMinimizerBrent2 N_photons: 260000, Initial (V12cm, V12diff, V34cm, V34diff) [V]: (-5.944700, 0.228942, 15.243497, 89.610520), num_iterations: 6, 60617.254333171 2024-11-03T06:06:14.386000+00:00 62836 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60617.254342014 2024-11-03T06:06:15.150000+00:00 62837 switchBeam Beam: A 60617.254376134 2024-11-03T06:06:18.098000+00:00 62838 SecularXYZ N_photons: 6000, num_pts: 50, TicklerAtt (attX, attY, attZ) [dB]: (8.0, 5.0, 18.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.944700, 0.225175, 14.961037, 89.430152) 60617.260694005 2024-11-03T06:15:23.962000+00:00 62839 MeasureFluorescenceLevels Bright : 61.1 +- 8.8, Dark : 0.9 +- 0.9, Threshold: int( ceil( 7.3 ) ) = 8, N_meas = 50, t_gate = 5.0 ms 60617.261162952 2024-11-03T06:16:04.479000+00:00 62840 SecularXYZ N_photons: 6000, num_pts: 50, TicklerAtt (attX, attY, attZ) [dB]: (8.0, 5.0, 19.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.944700, 0.225175, 14.961037, 89.430152) 60617.267930185 2024-11-03T06:25:49.168000+00:00 62841 MeasureFluorescenceLevels Bright : 114.0 +- 10.2, Dark : 2.2 +- 1.5, Threshold: int( ceil( 15.7 ) ) = 16, N_meas = 100, t_gate = 10.0 ms 60617.268439398 2024-11-03T06:26:33.164000+00:00 62842 MeasureFluorescenceLevels Bright : 55.8 +- 6.2, Dark : 0.8 +- 1.0, Threshold: int( ceil( 6.7 ) ) = 7, N_meas = 200, t_gate = 5.0 ms 60617.269848102 2024-11-03T06:28:34.876000+00:00 62843 MeasureFluorescenceLevels Bright : 59.1 +- 7.7, Dark : 1.0 +- 1.0, Threshold: int( ceil( 7.5 ) ) = 8, N_meas = 2000, t_gate = 5.0 ms 60617.269953530 2024-11-03T06:28:43.985000+00:00 62844 MeasureFluorescenceLevels Bright : 56.8 +- 6.9, Dark : 1.1 +- 1.0, Threshold: int( ceil( 7.8 ) ) = 8, N_meas = 50, t_gate = 5.0 ms 60617.271159340 2024-11-03T06:30:28.167000+00:00 62845 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60617.271211493 2024-11-03T06:30:32.673000+00:00 62846 switchBeam Beam: B 60617.271298437 2024-11-03T06:30:40.185000+00:00 62847 StateMachineSupervisor Start Clockrun 60617.271322211 2024-11-03T06:30:42.239000+00:00 62849 switchBeam Beam: B 60617.271331979 2024-11-03T06:30:43.083000+00:00 62850 Lock_to_C124421 t_probe [us] = 148000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 441, pmt_thr = 8, T_p0avg_s = 900.0, N_p0avg = 220, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8491, LCminus [V] = 3.3311, 60617.306685255 2024-11-03T07:21:37.606000+00:00 62852 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60617.306715417 2024-11-03T07:21:40.212000+00:00 62853 switchBeam Beam: B 60617.306753275 2024-11-03T07:21:43.483000+00:00 62854 SecularXYZ N_photons: 3000, num_pts: 50, TicklerAtt (attX, attY, attZ) [dB]: (8.0, 5.0, 19.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.944700, 0.225175, 14.961037, 89.430152) 60617.311417789 2024-11-03T07:28:26.497000+00:00 62855 switchBeam Beam: C 60617.311506505 2024-11-03T07:28:34.162000+00:00 62857 SecularXYZ N_photons: 3000, num_pts: 50, TicklerAtt (attX, attY, attZ) [dB]: (8.0, 5.0, 19.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.944700, 0.225175, 14.961037, 89.430152) 60617.316223472 2024-11-03T07:35:21.708000+00:00 62859 switchBeam Beam: A 60617.316229560 2024-11-03T07:35:22.234000+00:00 62860 SecularXYZ N_photons: 3000, num_pts: 50, TicklerAtt (attX, attY, attZ) [dB]: (8.0, 5.0, 19.0), (V12cm, V12diff, V34cm, V34diff) [V]: (-5.944700, 0.225175, 14.961037, 89.430152) 60617.320952685 2024-11-03T07:42:10.312000+00:00 62861 switchBeam Beam: B 60617.320982269 2024-11-03T07:42:12.868000+00:00 62862 StateMachineSupervisor Start Clockrun 60617.321005822 2024-11-03T07:42:14.903000+00:00 62864 switchBeam Beam: B 60617.321015787 2024-11-03T07:42:15.764000+00:00 62865 Lock_to_C124421 t_probe [us] = 148000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 441, pmt_thr = 8, T_p0avg_s = 900.0, N_p0avg = 220, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8491, LCminus [V] = 3.3311, 60617.915000822 2024-11-03T21:57:36.071000+00:00 62862 StateMachineSupervisor Ion Dark 60617.915006852 2024-11-03T21:57:36.592000+00:00 62862 StateMachineSupervisor Recover Ion 60617.915016019 2024-11-03T21:57:37.384000+00:00 62866 switchBeam Beam: ABC 60617.915047952 2024-11-03T21:57:40.143000+00:00 62869 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60617.915146551 2024-11-03T21:57:48.662000+00:00 62870 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60617.915165752 2024-11-03T21:57:50.321000+00:00 62872 switchBeam Beam: B 60617.915187928 2024-11-03T21:57:52.237000+00:00 62873 MeasureFluorescenceLevels Bright : 54.6 +- 7.2, Dark : 0.1 +- 0.3, Threshold: int( ceil( 2.2 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60617.915199167 2024-11-03T21:57:53.208000+00:00 62862 StateMachineSupervisor Ion Bright, Start Clockrun 60617.915232315 2024-11-03T21:57:56.072000+00:00 62876 switchBeam Beam: B 60617.915241470 2024-11-03T21:57:56.863000+00:00 62877 Lock_to_C124421 t_probe [us] = 148000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 441, pmt_thr = 8, T_p0avg_s = 900.0, N_p0avg = 220, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8491, LCminus [V] = 3.3311, 60617.974067211 2024-11-03T23:22:39.407000+00:00 62862 StateMachineSupervisor Ion Dark 60617.974073299 2024-11-03T23:22:39.933000+00:00 62862 StateMachineSupervisor Recover Ion 60617.974082743 2024-11-03T23:22:40.749000+00:00 62878 switchBeam Beam: ABC 60617.974114132 2024-11-03T23:22:43.461000+00:00 62881 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60617.974213495 2024-11-03T23:22:52.046000+00:00 62882 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60617.974232153 2024-11-03T23:22:53.658000+00:00 62884 switchBeam Beam: B 60617.974254305 2024-11-03T23:22:55.572000+00:00 62885 MeasureFluorescenceLevels Bright : 53.1 +- 6.5, Dark : 0.1 +- 0.4, Threshold: int( ceil( 2.3 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60617.974265417 2024-11-03T23:22:56.532000+00:00 62862 StateMachineSupervisor Ion Bright, Start Clockrun 60617.974298530 2024-11-03T23:22:59.393000+00:00 62888 switchBeam Beam: B 60617.974308287 2024-11-03T23:23:00.236000+00:00 62889 Lock_to_C124421 t_probe [us] = 148000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 441, pmt_thr = 8, T_p0avg_s = 900.0, N_p0avg = 220, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8491, LCminus [V] = 3.3311, # End of file 60617_artiq_log.txt