# Start of file 60589_artiq_log.txt # First point: 60589.028603 2024-10-06T00:41:11.295000+00:00 # Last point: 60589.979251 2024-10-06T23:30:07.308000+00:00 # Num rows: 40 # File updated: 2024-10-07T00:10:38.251441 # Columns: MJD DATE RID PROGRAM MESSAGE 60589.028602951 2024-10-06T00:41:11.295000+00:00 57072 StateMachineSupervisor Ion Dark 60589.028609074 2024-10-06T00:41:11.824000+00:00 57072 StateMachineSupervisor Recover Ion 60589.028618009 2024-10-06T00:41:12.596000+00:00 57076 switchBeam Beam: ABC 60589.028649734 2024-10-06T00:41:15.337000+00:00 57079 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60589.028748820 2024-10-06T00:41:23.898000+00:00 57080 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60589.028766655 2024-10-06T00:41:25.439000+00:00 57082 switchBeam Beam: B 60589.028789444 2024-10-06T00:41:27.408000+00:00 57083 MeasureFluorescenceLevels Bright : 60.5 +- 8.4, Dark : 0.1 +- 0.2, Threshold: int( ceil( 1.9 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60589.028801308 2024-10-06T00:41:28.433000+00:00 57072 StateMachineSupervisor Ion Bright, Start Clockrun 60589.028833252 2024-10-06T00:41:31.193000+00:00 57086 switchBeam Beam: B 60589.028843461 2024-10-06T00:41:32.075000+00:00 57087 Lock_to_C124421 t_probe [us] = 125000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 510, pmt_thr = 10, T_p0avg_s = 900.0, N_p0avg = 255, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8483, LCminus [V] = 3.2854, 60589.196179676 2024-10-06T04:42:29.924000+00:00 57089 SetCoolingAOM mode : umotion, AOM_f (MHz) : 207.5, ATT_Main (dB) = 9.0, ATT_SP (dB) = 19.0. 60589.196217245 2024-10-06T04:42:33.170000+00:00 57090 MicroMotionMinimizerBrent2 N_photons: 160000, Initial (V12cm, V12diff, V34cm, V34diff) [V]: (-5.984000, 0.225287, 15.137389, 88.216220), num_iterations: 6, 60589.197674769 2024-10-06T04:44:39.100000+00:00 57093 SetAtt att_RCDAT : 20.0 dB 60589.198718322 2024-10-06T04:46:09.263000+00:00 57091 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60589.198726285 2024-10-06T04:46:09.951000+00:00 57092 switchBeam Beam: B 60589.200959953 2024-10-06T04:49:22.940000+00:00 57094 RabiFlopping freq_mode C1+ ,sideband_mode Carrier, 60589.201003484 2024-10-06T04:49:26.701000+00:00 57095 StateMachineSupervisor Start Clockrun 60589.201036053 2024-10-06T04:49:29.515000+00:00 57097 switchBeam Beam: B 60589.201046053 2024-10-06T04:49:30.379000+00:00 57098 Lock_to_C124421 t_probe [us] = 125000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 510, pmt_thr = 10, T_p0avg_s = 900.0, N_p0avg = 255, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 20.00, LCplus [V] = 1.8483, LCminus [V] = 3.2854, 60589.201118900 2024-10-06T04:49:36.673000+00:00 57099 SetAtt att_RCDAT : 25.0 dB 60589.727226956 2024-10-06T17:27:12.409000+00:00 57095 StateMachineSupervisor Ion Dark 60589.727232952 2024-10-06T17:27:12.927000+00:00 57095 StateMachineSupervisor Recover Ion 60589.727241504 2024-10-06T17:27:13.666000+00:00 57100 switchBeam Beam: ABC 60589.727272836 2024-10-06T17:27:16.373000+00:00 57103 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60589.727372708 2024-10-06T17:27:25.002000+00:00 57104 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60589.727390509 2024-10-06T17:27:26.540000+00:00 57106 switchBeam Beam: B 60589.727413310 2024-10-06T17:27:28.510000+00:00 57107 MeasureFluorescenceLevels Bright : 57.8 +- 8.0, Dark : 0.1 +- 0.3, Threshold: int( ceil( 2.2 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60589.727425278 2024-10-06T17:27:29.544000+00:00 57095 StateMachineSupervisor Ion Bright, Start Clockrun 60589.727457951 2024-10-06T17:27:32.367000+00:00 57110 switchBeam Beam: B 60589.727468785 2024-10-06T17:27:33.303000+00:00 57111 Lock_to_C124421 t_probe [us] = 125000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 510, pmt_thr = 10, T_p0avg_s = 900.0, N_p0avg = 255, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8483, LCminus [V] = 3.2854, 60589.979009132 2024-10-06T23:29:46.389000+00:00 57095 StateMachineSupervisor Ion Dark 60589.979015313 2024-10-06T23:29:46.923000+00:00 57095 StateMachineSupervisor Recover Ion 60589.979023634 2024-10-06T23:29:47.642000+00:00 57112 switchBeam Beam: ABC 60589.979055197 2024-10-06T23:29:50.369000+00:00 57115 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60589.979155614 2024-10-06T23:29:59.045000+00:00 57116 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60589.979173576 2024-10-06T23:30:00.597000+00:00 57118 switchBeam Beam: B 60589.979196539 2024-10-06T23:30:02.581000+00:00 57119 MeasureFluorescenceLevels Bright : 58.0 +- 7.5, Dark : 0.1 +- 0.3, Threshold: int( ceil( 1.9 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60589.979207558 2024-10-06T23:30:03.533000+00:00 57095 StateMachineSupervisor Ion Bright, Start Clockrun 60589.979240405 2024-10-06T23:30:06.371000+00:00 57122 switchBeam Beam: B 60589.979251250 2024-10-06T23:30:07.308000+00:00 57123 Lock_to_C124421 t_probe [us] = 125000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 510, pmt_thr = 10, T_p0avg_s = 900.0, N_p0avg = 255, (C1, C2, C4) att [dB] = (15.00, 16.45, 16.12), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8483, LCminus [V] = 3.2854, # End of file 60589_artiq_log.txt