# Start of file 60522_artiq_log.txt # First point: 60522.159940 2024-07-31T03:50:18.786000+00:00 # Last point: 60522.346956 2024-07-31T08:19:37.013000+00:00 # Num rows: 20 # File updated: 2024-08-15T19:23:59.770809 # Columns: MJD DATE RID PROGRAM MESSAGE 60522.159939653 2024-07-31T03:50:18.786000+00:00 50704 StateMachineSupervisor Ion Dark 60522.159945683 2024-07-31T03:50:19.307000+00:00 50704 StateMachineSupervisor Recover Ion 60522.159954630 2024-07-31T03:50:20.080000+00:00 50768 switchBeam Beam: ABC 60522.159991053 2024-07-31T03:50:23.227000+00:00 50771 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60522.160086400 2024-07-31T03:50:31.465000+00:00 50772 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60522.160106088 2024-07-31T03:50:33.166000+00:00 50774 switchBeam Beam: B 60522.160129641 2024-07-31T03:50:35.201000+00:00 50775 MeasureFluorescenceLevels Bright : 62.6 +- 7.9, Dark : 0.1 +- 0.4, Threshold: int( ceil( 2.4 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60522.160143680 2024-07-31T03:50:36.414000+00:00 50704 StateMachineSupervisor Ion Bright, Start Clockrun 60522.160177153 2024-07-31T03:50:39.306000+00:00 50778 switchBeam Beam: B 60522.160188194 2024-07-31T03:50:40.260000+00:00 50779 Lock_to_C124421 t_probe [us] = 132000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 486, pmt_thr = 10, T_p0avg_s = 900.0, N_p0avg = 243, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 60522.346705347 2024-07-31T08:19:15.342000+00:00 50704 StateMachineSupervisor Ion Dark 60522.346711389 2024-07-31T08:19:15.864000+00:00 50704 StateMachineSupervisor Recover Ion 60522.346720475 2024-07-31T08:19:16.649000+00:00 50780 switchBeam Beam: ABC 60522.346754259 2024-07-31T08:19:19.568000+00:00 50783 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60522.346852940 2024-07-31T08:19:28.094000+00:00 50784 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60522.346873576 2024-07-31T08:19:29.877000+00:00 50786 switchBeam Beam: B 60522.346897801 2024-07-31T08:19:31.970000+00:00 50787 MeasureFluorescenceLevels Bright : 62.5 +- 8.7, Dark : 0.1 +- 0.3, Threshold: int( ceil( 2.4 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60522.346909421 2024-07-31T08:19:32.974000+00:00 50704 StateMachineSupervisor Ion Bright, Start Clockrun 60522.346945208 2024-07-31T08:19:36.066000+00:00 50790 switchBeam Beam: B 60522.346956169 2024-07-31T08:19:37.013000+00:00 50791 Lock_to_C124421 t_probe [us] = 132000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 486, pmt_thr = 10, T_p0avg_s = 900.0, N_p0avg = 243, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 # End of file 60522_artiq_log.txt