# Start of file 60521_artiq_log.txt # First point: 60521.456167 2024-07-30T10:56:52.849000+00:00 # Last point: 60521.939701 2024-07-30T22:33:10.195000+00:00 # Num rows: 86 # File updated: 2024-08-15T19:24:27.897187 # Columns: MJD DATE RID PROGRAM MESSAGE 60521.456167234 2024-07-30T10:56:52.849000+00:00 50654 switchBeam Beam: ABC 60521.456232731 2024-07-30T10:56:58.508000+00:00 50655 SetCoolingAOM mode : umotion, AOM_f (MHz) : 207.5, ATT_Main (dB) = 9.0, ATT_SP (dB) = 19.0. 60521.459734722 2024-07-30T11:02:01.080000+00:00 50658 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60521.466549548 2024-07-30T11:11:49.881000+00:00 50662 SetCoolingAOM mode : umotion, AOM_f (MHz) : 207.5, ATT_Main (dB) = 9.0, ATT_SP (dB) = 19.0. 60521.466558773 2024-07-30T11:11:50.678000+00:00 50663 switchBeam Beam: B 60521.466920775 2024-07-30T11:12:21.955000+00:00 50664 MicroMotionMeasurement3Beam Beam: A, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.418000, duration [s]: 18.766 60521.467659757 2024-07-30T11:13:25.803000+00:00 50665 MicroMotionMinimizerBrent N_photons: 200000, Initial (V12cm, V12diff, V34cm, V34diff) [V]: (-6.022100, 0.229542, 16.066939, 85.377235)num_iterations: 5, 60521.471786400 2024-07-30T11:19:22.345000+00:00 50666 MicroMotionMeasurement3Beam Beam: A, N_photons: 600000, N_bins: 25, f_mod [MHz]: 14.418000, duration [s]: 89.704 60521.471809757 2024-07-30T11:19:24.363000+00:00 50667 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60521.471826748 2024-07-30T11:19:25.831000+00:00 50668 switchBeam Beam: B 60521.472832453 2024-07-30T11:20:52.724000+00:00 50670 switchBeam Beam: B 60521.479507974 2024-07-30T11:30:29.489000+00:00 50671 CoolingDetuningScan From [AOM MHz]: 180.000, To [AOM MHz]: 222.000, num_pts: 200, t_gate (ms) = 1000.0 60521.486938553 2024-07-30T11:41:11.491000+00:00 50674 SetAtt att_RCDAT : 20.0 dB 60521.488112616 2024-07-30T11:42:52.930000+00:00 50673 SetLockFreqs Linecenter [MHz AOM]: 75.563581, abs(B) [uT]: 4.796040000, EQS C1, C2, C4 [Hz]: 0.0, 0.0, 0.0 60521.488163623 2024-07-30T11:42:57.337000+00:00 50675 StateMachineSupervisor Start Clockrun 60521.488187720 2024-07-30T11:42:59.419000+00:00 50677 switchBeam Beam: B 60521.488199155 2024-07-30T11:43:00.407000+00:00 50678 Lock_to_C124421 t_probe [us] = 32000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1386, pmt_thr = 20, T_p0avg_s = 900.0, N_p0avg = 694, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 20.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 60521.489930232 2024-07-30T11:45:29.972000+00:00 50680 SetLockFreqs Linecenter [MHz AOM]: 75.563587, abs(B) [uT]: 4.797500000, EQS C1, C2, C4 [Hz]: 0.0, 0.0, 0.0 60521.489946007 2024-07-30T11:45:31.335000+00:00 50681 StateMachineSupervisor Start Clockrun 60521.489969502 2024-07-30T11:45:33.365000+00:00 50683 switchBeam Beam: B 60521.489980625 2024-07-30T11:45:34.326000+00:00 50684 Lock_to_C124421 t_probe [us] = 32000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1386, pmt_thr = 20, T_p0avg_s = 900.0, N_p0avg = 694, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 20.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 60521.492365185 2024-07-30T11:49:00.352000+00:00 50686 SetLockFreqs Linecenter [MHz AOM]: 75.563595, abs(B) [uT]: 4.797000000, EQS C1, C2, C4 [Hz]: 0.0, 0.0, 0.0 60521.492380833 2024-07-30T11:49:01.704000+00:00 50687 StateMachineSupervisor Start Clockrun 60521.492407408 2024-07-30T11:49:04+00:00 50689 switchBeam Beam: B 60521.492420301 2024-07-30T11:49:05.114000+00:00 50690 Lock_to_C124421 t_probe [us] = 32000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 1386, pmt_thr = 20, T_p0avg_s = 900.0, N_p0avg = 694, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 20.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 60521.493338391 2024-07-30T11:50:24.437000+00:00 50692 SetAtt att_RCDAT : 23.0 dB 60521.493353495 2024-07-30T11:50:25.742000+00:00 50693 StateMachineSupervisor Start Clockrun 60521.493377905 2024-07-30T11:50:27.851000+00:00 50695 switchBeam Beam: B 60521.493388449 2024-07-30T11:50:28.762000+00:00 50696 Lock_to_C124421 t_probe [us] = 65000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 861, pmt_thr = 20, T_p0avg_s = 900.0, N_p0avg = 431, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 23.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 60521.497095718 2024-07-30T11:55:49.070000+00:00 50698 SetAtt att_RCDAT : 26.0 dB 60521.497110914 2024-07-30T11:55:50.383000+00:00 50699 StateMachineSupervisor Start Clockrun 60521.497135243 2024-07-30T11:55:52.485000+00:00 50701 switchBeam Beam: B 60521.497146655 2024-07-30T11:55:53.471000+00:00 50702 Lock_to_C124421 t_probe [us] = 132000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 486, pmt_thr = 20, T_p0avg_s = 900.0, N_p0avg = 243, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 60521.563663935 2024-07-30T13:31:40.564000+00:00 50704 StateMachineSupervisor Start Clockrun 60521.563687801 2024-07-30T13:31:42.626000+00:00 50706 switchBeam Beam: B 60521.563701250 2024-07-30T13:31:43.788000+00:00 50707 Lock_to_C124421 t_probe [us] = 132000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 486, pmt_thr = 10, T_p0avg_s = 900.0, N_p0avg = 243, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 60521.626700995 2024-07-30T15:02:26.966000+00:00 50704 StateMachineSupervisor Ion Dark 60521.626707141 2024-07-30T15:02:27.497000+00:00 50704 StateMachineSupervisor Recover Ion 60521.626715914 2024-07-30T15:02:28.255000+00:00 50708 switchBeam Beam: ABC 60521.626750035 2024-07-30T15:02:31.203000+00:00 50711 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60521.626848496 2024-07-30T15:02:39.710000+00:00 50712 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60521.626869109 2024-07-30T15:02:41.491000+00:00 50714 switchBeam Beam: B 60521.626893715 2024-07-30T15:02:43.617000+00:00 50715 MeasureFluorescenceLevels Bright : 61.9 +- 7.7, Dark : 0.0 +- 0.2, Threshold: int( ceil( 1.6 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60521.626905070 2024-07-30T15:02:44.598000+00:00 50704 StateMachineSupervisor Ion Bright, Start Clockrun 60521.626940393 2024-07-30T15:02:47.650000+00:00 50718 switchBeam Beam: B 60521.626950996 2024-07-30T15:02:48.566000+00:00 50719 Lock_to_C124421 t_probe [us] = 132000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 486, pmt_thr = 10, T_p0avg_s = 900.0, N_p0avg = 243, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 60521.679281609 2024-07-30T16:18:09.931000+00:00 50704 StateMachineSupervisor Ion Dark 60521.679287789 2024-07-30T16:18:10.465000+00:00 50704 StateMachineSupervisor Recover Ion 60521.679297060 2024-07-30T16:18:11.266000+00:00 50720 switchBeam Beam: ABC 60521.679330776 2024-07-30T16:18:14.179000+00:00 50723 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60521.679428345 2024-07-30T16:18:22.609000+00:00 50724 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60521.679448796 2024-07-30T16:18:24.376000+00:00 50726 switchBeam Beam: B 60521.679472222 2024-07-30T16:18:26.400000+00:00 50727 MeasureFluorescenceLevels Bright : 62.0 +- 8.2, Dark : 0.1 +- 0.3, Threshold: int( ceil( 2.1 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60521.679485683 2024-07-30T16:18:27.563000+00:00 50704 StateMachineSupervisor Ion Bright, Start Clockrun 60521.679522488 2024-07-30T16:18:30.743000+00:00 50730 switchBeam Beam: B 60521.679533820 2024-07-30T16:18:31.722000+00:00 50731 Lock_to_C124421 t_probe [us] = 132000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 486, pmt_thr = 10, T_p0avg_s = 900.0, N_p0avg = 243, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 60521.684700486 2024-07-30T16:25:58.122000+00:00 50704 StateMachineSupervisor Ion Dark 60521.684706563 2024-07-30T16:25:58.647000+00:00 50704 StateMachineSupervisor Recover Ion 60521.684715984 2024-07-30T16:25:59.461000+00:00 50732 switchBeam Beam: ABC 60521.684748634 2024-07-30T16:26:02.282000+00:00 50735 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60521.684849282 2024-07-30T16:26:10.978000+00:00 50736 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60521.684870139 2024-07-30T16:26:12.780000+00:00 50738 switchBeam Beam: B 60521.684893299 2024-07-30T16:26:14.781000+00:00 50739 MeasureFluorescenceLevels Bright : 62.8 +- 6.8, Dark : 0.1 +- 0.2, Threshold: int( ceil( 1.8 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60521.684904537 2024-07-30T16:26:15.752000+00:00 50704 StateMachineSupervisor Ion Bright, Start Clockrun 60521.684940753 2024-07-30T16:26:18.881000+00:00 50742 switchBeam Beam: B 60521.684952419 2024-07-30T16:26:19.889000+00:00 50743 Lock_to_C124421 t_probe [us] = 132000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 486, pmt_thr = 10, T_p0avg_s = 900.0, N_p0avg = 243, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 60521.761731655 2024-07-30T18:16:53.615000+00:00 50704 StateMachineSupervisor Ion Dark 60521.761737882 2024-07-30T18:16:54.153000+00:00 50704 StateMachineSupervisor Recover Ion 60521.761749028 2024-07-30T18:16:55.116000+00:00 50744 switchBeam Beam: ABC 60521.761783901 2024-07-30T18:16:58.129000+00:00 50747 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60521.761878090 2024-07-30T18:17:06.267000+00:00 50748 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60521.761897917 2024-07-30T18:17:07.980000+00:00 50750 switchBeam Beam: B 60521.761920127 2024-07-30T18:17:09.899000+00:00 50751 MeasureFluorescenceLevels Bright : 63.0 +- 7.7, Dark : 0.1 +- 0.3, Threshold: int( ceil( 2.2 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60521.761930058 2024-07-30T18:17:10.757000+00:00 50704 StateMachineSupervisor Ion Bright, Start Clockrun 60521.761964688 2024-07-30T18:17:13.749000+00:00 50754 switchBeam Beam: B 60521.761974502 2024-07-30T18:17:14.597000+00:00 50755 Lock_to_C124421 t_probe [us] = 132000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 486, pmt_thr = 10, T_p0avg_s = 900.0, N_p0avg = 243, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 60521.939453078 2024-07-30T22:32:48.746000+00:00 50704 StateMachineSupervisor Ion Dark 60521.939459259 2024-07-30T22:32:49.280000+00:00 50704 StateMachineSupervisor Recover Ion 60521.939469433 2024-07-30T22:32:50.159000+00:00 50756 switchBeam Beam: ABC 60521.939506817 2024-07-30T22:32:53.389000+00:00 50759 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60521.939600416 2024-07-30T22:33:01.476000+00:00 50760 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60521.939621944 2024-07-30T22:33:03.336000+00:00 50762 switchBeam Beam: B 60521.939647245 2024-07-30T22:33:05.522000+00:00 50763 MeasureFluorescenceLevels Bright : 62.0 +- 8.2, Dark : 0.1 +- 0.3, Threshold: int( ceil( 2.1 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60521.939657257 2024-07-30T22:33:06.387000+00:00 50704 StateMachineSupervisor Ion Bright, Start Clockrun 60521.939690347 2024-07-30T22:33:09.246000+00:00 50766 switchBeam Beam: B 60521.939701331 2024-07-30T22:33:10.195000+00:00 50767 Lock_to_C124421 t_probe [us] = 132000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 486, pmt_thr = 10, T_p0avg_s = 900.0, N_p0avg = 243, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 # End of file 60521_artiq_log.txt