# Start of file 60510_artiq_log.txt # First point: 60510.182118 2024-07-19T04:22:15.014000+00:00 # Last point: 60510.789219 2024-07-19T18:56:28.550000+00:00 # Num rows: 64 # File updated: 2024-08-15T19:28:22.344949 # Columns: MJD DATE RID PROGRAM MESSAGE 60510.182118217 2024-07-19T04:22:15.014000+00:00 49946 SetCoolingAOM mode : umotion, AOM_f (MHz) : 207.5, ATT_Main (dB) = 9.0, ATT_SP (dB) = 19.0. 60510.183248091 2024-07-19T04:23:52.635000+00:00 49947 MicroMotionMeasurement3Beam Beam: A, N_photons: 600000, N_bins: 25, f_mod [MHz]: 14.418000, duration [s]: 94.779 60510.183677257 2024-07-19T04:24:29.715000+00:00 49948 MicroMotionMinimizerBrent N_photons: 200000, Initial (V12cm, V12diff, V34cm, V34diff) [V]: (-6.022100, 0.228840, 16.080552, 85.402426)num_iterations: 5, 60510.188035451 2024-07-19T04:30:46.263000+00:00 49949 MicroMotionMeasurement3Beam Beam: A, N_photons: 600000, N_bins: 25, f_mod [MHz]: 14.418000, duration [s]: 95.111 60510.188057535 2024-07-19T04:30:48.171000+00:00 49950 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60510.188069873 2024-07-19T04:30:49.237000+00:00 49951 switchBeam Beam: B 60510.188097558 2024-07-19T04:30:51.629000+00:00 49952 StateMachineSupervisor Start Clockrun 60510.188131111 2024-07-19T04:30:54.528000+00:00 49954 switchBeam Beam: B 60510.188142431 2024-07-19T04:30:55.506000+00:00 49955 Lock_to_C124421 t_probe [us] = 132000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 486, pmt_thr = 20, T_p0avg_s = 900.0, N_p0avg = 243, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 60510.286361794 2024-07-19T06:52:21.659000+00:00 49952 StateMachineSupervisor Ion Dark 60510.286367813 2024-07-19T06:52:22.179000+00:00 49952 StateMachineSupervisor Recover Ion 60510.286377072 2024-07-19T06:52:22.979000+00:00 49956 switchBeam Beam: ABC 60510.286410104 2024-07-19T06:52:25.833000+00:00 49959 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60510.286508380 2024-07-19T06:52:34.324000+00:00 49960 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60510.286527014 2024-07-19T06:52:35.934000+00:00 49962 switchBeam Beam: B 60510.286550914 2024-07-19T06:52:37.999000+00:00 49963 MeasureFluorescenceLevels Bright : 57.5 +- 6.9, Dark : 0.1 +- 0.4, Threshold: int( ceil( 2.0 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60510.286559942 2024-07-19T06:52:38.779000+00:00 49952 StateMachineSupervisor Ion Bright, Start Clockrun 60510.286594560 2024-07-19T06:52:41.770000+00:00 49966 switchBeam Beam: B 60510.286605440 2024-07-19T06:52:42.710000+00:00 49967 Lock_to_C124421 t_probe [us] = 132000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 486, pmt_thr = 20, T_p0avg_s = 900.0, N_p0avg = 243, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 60510.328276053 2024-07-19T07:52:43.051000+00:00 49952 StateMachineSupervisor Ion Dark 60510.328282083 2024-07-19T07:52:43.572000+00:00 49952 StateMachineSupervisor Recover Ion 60510.328291053 2024-07-19T07:52:44.347000+00:00 49968 switchBeam Beam: ABC 60510.328324167 2024-07-19T07:52:47.208000+00:00 49971 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60510.328423299 2024-07-19T07:52:55.773000+00:00 49972 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60510.328442373 2024-07-19T07:52:57.421000+00:00 49974 switchBeam Beam: B 60510.328465683 2024-07-19T07:52:59.435000+00:00 49975 MeasureFluorescenceLevels Bright : 57.1 +- 8.3, Dark : 0.0 +- 0.2, Threshold: int( ceil( 1.5 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60510.328474248 2024-07-19T07:53:00.175000+00:00 49952 StateMachineSupervisor Ion Bright, Start Clockrun 60510.328509792 2024-07-19T07:53:03.246000+00:00 49978 switchBeam Beam: B 60510.328519861 2024-07-19T07:53:04.116000+00:00 49979 Lock_to_C124421 t_probe [us] = 132000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 486, pmt_thr = 20, T_p0avg_s = 900.0, N_p0avg = 243, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 60510.594817419 2024-07-19T14:16:32.225000+00:00 49980 switchBeam Beam: A 60510.595267500 2024-07-19T14:17:11.112000+00:00 49983 MeasureFluorescenceLevels Bright : 0.1 +- 0.2, Dark : 0.0 +- 0.1, Threshold: int( ceil( 0.0 ) ) = 1, N_meas = 100, t_gate = 5.0 ms 60510.595329225 2024-07-19T14:17:16.445000+00:00 49984 switchBeam Beam: B 60510.595402083 2024-07-19T14:17:22.740000+00:00 49985 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60510.595486528 2024-07-19T14:17:30.036000+00:00 49986 switchBeam Beam: A 60510.599995579 2024-07-19T14:23:59.618000+00:00 49990 switchBeam Beam: B 60510.600113530 2024-07-19T14:24:09.809000+00:00 49991 SetCoolingAOM mode : umotion, AOM_f (MHz) : 207.5, ATT_Main (dB) = 9.0, ATT_SP (dB) = 19.0. 60510.601256181 2024-07-19T14:25:48.534000+00:00 49992 MicroMotionMeasurement3Beam Beam: A, N_photons: 600000, N_bins: 25, f_mod [MHz]: 14.418000, duration [s]: 87.696 60510.601447662 2024-07-19T14:26:05.078000+00:00 49993 MicroMotionMinimizerBrent N_photons: 200000, Initial (V12cm, V12diff, V34cm, V34diff) [V]: (-6.022100, 0.229452, 15.946608, 85.309597)num_iterations: 5, 60510.605492338 2024-07-19T14:31:54.538000+00:00 49994 MicroMotionMeasurement3Beam Beam: A, N_photons: 600000, N_bins: 25, f_mod [MHz]: 14.418000, duration [s]: 87.926 60510.605513414 2024-07-19T14:31:56.359000+00:00 49995 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60510.605526458 2024-07-19T14:31:57.486000+00:00 49996 switchBeam Beam: B 60510.605569283 2024-07-19T14:32:01.186000+00:00 49997 StateMachineSupervisor Start Clockrun 60510.605598646 2024-07-19T14:32:03.723000+00:00 49999 switchBeam Beam: B 60510.605610185 2024-07-19T14:32:04.720000+00:00 50000 Lock_to_C124421 t_probe [us] = 132000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 486, pmt_thr = 20, T_p0avg_s = 900.0, N_p0avg = 243, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 60510.662812812 2024-07-19T15:54:27.027000+00:00 49997 StateMachineSupervisor Ion Dark 60510.662818924 2024-07-19T15:54:27.555000+00:00 49997 StateMachineSupervisor Recover Ion 60510.662828137 2024-07-19T15:54:28.351000+00:00 50001 switchBeam Beam: ABC 60510.662860718 2024-07-19T15:54:31.166000+00:00 50004 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60510.662959988 2024-07-19T15:54:39.743000+00:00 50005 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60510.662979607 2024-07-19T15:54:41.438000+00:00 50007 switchBeam Beam: B 60510.663002731 2024-07-19T15:54:43.436000+00:00 50008 MeasureFluorescenceLevels Bright : 62.7 +- 7.6, Dark : 0.1 +- 0.4, Threshold: int( ceil( 2.7 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60510.663016967 2024-07-19T15:54:44.666000+00:00 49997 StateMachineSupervisor Ion Bright, Start Clockrun 60510.663052558 2024-07-19T15:54:47.741000+00:00 50011 switchBeam Beam: B 60510.663064120 2024-07-19T15:54:48.740000+00:00 50012 Lock_to_C124421 t_probe [us] = 132000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 486, pmt_thr = 20, T_p0avg_s = 900.0, N_p0avg = 243, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 60510.788975127 2024-07-19T18:56:07.451000+00:00 49997 StateMachineSupervisor Ion Dark 60510.788981192 2024-07-19T18:56:07.975000+00:00 49997 StateMachineSupervisor Recover Ion 60510.788990069 2024-07-19T18:56:08.742000+00:00 50013 switchBeam Beam: ABC 60510.789023357 2024-07-19T18:56:11.618000+00:00 50016 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60510.789121806 2024-07-19T18:56:20.124000+00:00 50017 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60510.789140475 2024-07-19T18:56:21.737000+00:00 50019 switchBeam Beam: B 60510.789164225 2024-07-19T18:56:23.789000+00:00 50020 MeasureFluorescenceLevels Bright : 65.1 +- 8.0, Dark : 0.1 +- 0.3, Threshold: int( ceil( 2.6 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60510.789173310 2024-07-19T18:56:24.574000+00:00 49997 StateMachineSupervisor Ion Bright, Start Clockrun 60510.789208403 2024-07-19T18:56:27.606000+00:00 50023 switchBeam Beam: B 60510.789219329 2024-07-19T18:56:28.550000+00:00 50024 Lock_to_C124421 t_probe [us] = 132000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 486, pmt_thr = 20, T_p0avg_s = 900.0, N_p0avg = 243, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8443, LCminus [V] = 3.2625 # End of file 60510_artiq_log.txt