# Start of file 60490_artiq_log.txt # First point: 60490.451427 2024-06-29T10:50:03.307000+00:00 # Last point: 60490.963965 2024-06-29T23:08:06.617000+00:00 # Num rows: 50 # File updated: 2024-08-15T19:49:09.341171 # Columns: MJD DATE RID PROGRAM MESSAGE 60490.451427164 2024-06-29T10:50:03.307000+00:00 48754 StateMachineSupervisor Ion Dark 60490.451433194 2024-06-29T10:50:03.828000+00:00 48754 StateMachineSupervisor Recover Ion 60490.451442245 2024-06-29T10:50:04.610000+00:00 48782 switchBeam Beam: ABC 60490.451475034 2024-06-29T10:50:07.443000+00:00 48785 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60490.451576516 2024-06-29T10:50:16.211000+00:00 48786 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60490.451595729 2024-06-29T10:50:17.871000+00:00 48788 switchBeam Beam: B 60490.451619734 2024-06-29T10:50:19.945000+00:00 48789 MeasureFluorescenceLevels Bright : 57.6 +- 7.6, Dark : 0.3 +- 0.5, Threshold: int( ceil( 4.2 ) ) = 5, N_meas = 100, t_gate = 5.0 ms 60490.451631099 2024-06-29T10:50:20.927000+00:00 48754 StateMachineSupervisor Ion Bright, Start Clockrun 60490.451668819 2024-06-29T10:50:24.186000+00:00 48792 switchBeam Beam: B 60490.451680347 2024-06-29T10:50:25.182000+00:00 48793 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 411, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 27.00, LCplus [V] = 1.8475, LCminus [V] = 3.2663 60490.454644248 2024-06-29T10:54:41.263000+00:00 48754 StateMachineSupervisor Ion Dark 60490.454650347 2024-06-29T10:54:41.790000+00:00 48754 StateMachineSupervisor Recover Ion 60490.454660069 2024-06-29T10:54:42.630000+00:00 48794 switchBeam Beam: ABC 60490.454694155 2024-06-29T10:54:45.575000+00:00 48797 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60490.454790776 2024-06-29T10:54:53.923000+00:00 48798 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60490.454810116 2024-06-29T10:54:55.594000+00:00 48800 switchBeam Beam: B 60490.454833426 2024-06-29T10:54:57.608000+00:00 48801 MeasureFluorescenceLevels Bright : 56.7 +- 6.8, Dark : 0.3 +- 0.6, Threshold: int( ceil( 4.4 ) ) = 5, N_meas = 100, t_gate = 5.0 ms 60490.454842488 2024-06-29T10:54:58.391000+00:00 48754 StateMachineSupervisor Ion Bright, Start Clockrun 60490.454876354 2024-06-29T10:55:01.317000+00:00 48804 switchBeam Beam: B 60490.454886736 2024-06-29T10:55:02.214000+00:00 48805 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 411, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 27.00, LCplus [V] = 1.8475, LCminus [V] = 3.2663 60490.565388542 2024-06-29T13:34:09.570000+00:00 48754 StateMachineSupervisor Ion Dark 60490.565394583 2024-06-29T13:34:10.092000+00:00 48754 StateMachineSupervisor Recover Ion 60490.565405996 2024-06-29T13:34:11.078000+00:00 48806 switchBeam Beam: ABC 60490.565444433 2024-06-29T13:34:14.399000+00:00 48809 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60490.565537095 2024-06-29T13:34:22.405000+00:00 48810 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60490.565559560 2024-06-29T13:34:24.346000+00:00 48812 switchBeam Beam: B 60490.565583877 2024-06-29T13:34:26.447000+00:00 48813 MeasureFluorescenceLevels Bright : 57.7 +- 7.8, Dark : 0.2 +- 0.5, Threshold: int( ceil( 3.8 ) ) = 4, N_meas = 100, t_gate = 5.0 ms 60490.565592512 2024-06-29T13:34:27.193000+00:00 48754 StateMachineSupervisor Ion Bright, Start Clockrun 60490.565627280 2024-06-29T13:34:30.197000+00:00 48816 switchBeam Beam: B 60490.565640012 2024-06-29T13:34:31.297000+00:00 48817 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 411, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 27.00, LCplus [V] = 1.8475, LCminus [V] = 3.2663 60490.767333264 2024-06-29T18:24:57.594000+00:00 48754 StateMachineSupervisor Ion Dark 60490.767339294 2024-06-29T18:24:58.115000+00:00 48754 StateMachineSupervisor Recover Ion 60490.767350833 2024-06-29T18:24:59.112000+00:00 48818 switchBeam Beam: ABC 60490.767384063 2024-06-29T18:25:01.983000+00:00 48821 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60490.767479618 2024-06-29T18:25:10.239000+00:00 48822 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60490.767502141 2024-06-29T18:25:12.185000+00:00 48824 switchBeam Beam: B 60490.767527535 2024-06-29T18:25:14.379000+00:00 48825 MeasureFluorescenceLevels Bright : 57.6 +- 7.8, Dark : 0.3 +- 0.6, Threshold: int( ceil( 4.2 ) ) = 5, N_meas = 100, t_gate = 5.0 ms 60490.767537199 2024-06-29T18:25:15.214000+00:00 48754 StateMachineSupervisor Ion Bright, Start Clockrun 60490.767571840 2024-06-29T18:25:18.207000+00:00 48828 switchBeam Beam: B 60490.767583461 2024-06-29T18:25:19.211000+00:00 48829 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 411, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 27.00, LCplus [V] = 1.8475, LCminus [V] = 3.2663 60490.963716516 2024-06-29T23:07:45.107000+00:00 48754 StateMachineSupervisor Ion Dark 60490.963722639 2024-06-29T23:07:45.636000+00:00 48754 StateMachineSupervisor Recover Ion 60490.963733171 2024-06-29T23:07:46.546000+00:00 48830 switchBeam Beam: ABC 60490.963767257 2024-06-29T23:07:49.491000+00:00 48833 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60490.963863438 2024-06-29T23:07:57.801000+00:00 48834 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60490.963884317 2024-06-29T23:07:59.605000+00:00 48836 switchBeam Beam: B 60490.963909109 2024-06-29T23:08:01.747000+00:00 48837 MeasureFluorescenceLevels Bright : 56.4 +- 7.6, Dark : 0.2 +- 0.5, Threshold: int( ceil( 3.1 ) ) = 4, N_meas = 100, t_gate = 5.0 ms 60490.963920486 2024-06-29T23:08:02.730000+00:00 48754 StateMachineSupervisor Ion Bright, Start Clockrun 60490.963955035 2024-06-29T23:08:05.715000+00:00 48840 switchBeam Beam: B 60490.963965475 2024-06-29T23:08:06.617000+00:00 48841 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 411, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.00, 16.20, 15.70), att_RCDAT [dB] = 27.00, LCplus [V] = 1.8475, LCminus [V] = 3.2663 # End of file 60490_artiq_log.txt