# Start of file 60463_artiq_log.txt # First point: 60463.170087 2024-06-02T04:04:55.543000+00:00 # Last point: 60463.904902 2024-06-02T21:43:03.553000+00:00 # Num rows: 40 # File updated: 2024-06-03T10:47:55.562146 # Columns: MJD DATE RID PROGRAM MESSAGE 60463.170087303 2024-06-02T04:04:55.543000+00:00 46451 StateMachineSupervisor Ion Dark 60463.170093357 2024-06-02T04:04:56.066000+00:00 46451 StateMachineSupervisor Recover Ion 60463.170104120 2024-06-02T04:04:56.996000+00:00 46455 switchBeam Beam: ABC 60463.170136424 2024-06-02T04:04:59.787000+00:00 46458 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60463.170234178 2024-06-02T04:05:08.233000+00:00 46459 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60463.170253322 2024-06-02T04:05:09.887000+00:00 46461 switchBeam Beam: B 60463.170277292 2024-06-02T04:05:11.958000+00:00 46462 MeasureFluorescenceLevels Bright : 56.6 +- 7.7, Dark : 59.0 +- 8.1, Threshold: int( ceil( 57.8 ) ) = 58, N_meas = 100, t_gate = 5.0 ms 60463.170291285 2024-06-02T04:05:13.167000+00:00 46451 StateMachineSupervisor Ion Bright, Start Clockrun 60463.170327905 2024-06-02T04:05:16.331000+00:00 46465 switchBeam Beam: B 60463.170338496 2024-06-02T04:05:17.246000+00:00 46466 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 411, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.00, 16.30, 15.57), att_RCDAT [dB] = 27.00, LCplus [V] = 1.8483, LCminus [V] = 3.2663 60463.325680359 2024-06-02T07:48:58.783000+00:00 46451 StateMachineSupervisor Ion Dark 60463.325686562 2024-06-02T07:48:59.319000+00:00 46451 StateMachineSupervisor Recover Ion 60463.325695914 2024-06-02T07:49:00.127000+00:00 46467 switchBeam Beam: ABC 60463.325728901 2024-06-02T07:49:02.977000+00:00 46470 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60463.325828067 2024-06-02T07:49:11.545000+00:00 46471 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60463.325848461 2024-06-02T07:49:13.307000+00:00 46473 switchBeam Beam: B 60463.325871725 2024-06-02T07:49:15.317000+00:00 46474 MeasureFluorescenceLevels Bright : 59.2 +- 8.0, Dark : 0.3 +- 0.5, Threshold: int( ceil( 3.9 ) ) = 4, N_meas = 100, t_gate = 5.0 ms 60463.325884502 2024-06-02T07:49:16.421000+00:00 46451 StateMachineSupervisor Ion Bright, Start Clockrun 60463.325918461 2024-06-02T07:49:19.355000+00:00 46477 switchBeam Beam: B 60463.325929329 2024-06-02T07:49:20.294000+00:00 46478 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 411, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.00, 16.30, 15.57), att_RCDAT [dB] = 27.00, LCplus [V] = 1.8483, LCminus [V] = 3.2663 60463.754510729 2024-06-02T18:06:29.727000+00:00 46451 StateMachineSupervisor Ion Dark 60463.754516794 2024-06-02T18:06:30.251000+00:00 46451 StateMachineSupervisor Recover Ion 60463.754527234 2024-06-02T18:06:31.153000+00:00 46479 switchBeam Beam: ABC 60463.754561007 2024-06-02T18:06:34.071000+00:00 46482 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60463.754657662 2024-06-02T18:06:42.422000+00:00 46483 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60463.754677755 2024-06-02T18:06:44.158000+00:00 46485 switchBeam Beam: B 60463.754701354 2024-06-02T18:06:46.197000+00:00 46486 MeasureFluorescenceLevels Bright : 56.1 +- 6.3, Dark : 0.4 +- 0.6, Threshold: int( ceil( 4.6 ) ) = 5, N_meas = 100, t_gate = 5.0 ms 60463.754714664 2024-06-02T18:06:47.347000+00:00 46451 StateMachineSupervisor Ion Bright, Start Clockrun 60463.754750833 2024-06-02T18:06:50.472000+00:00 46489 switchBeam Beam: B 60463.754761817 2024-06-02T18:06:51.421000+00:00 46490 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 411, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.00, 16.30, 15.57), att_RCDAT [dB] = 27.00, LCplus [V] = 1.8483, LCminus [V] = 3.2663 60463.904658357 2024-06-02T21:42:42.482000+00:00 46451 StateMachineSupervisor Ion Dark 60463.904664468 2024-06-02T21:42:43.010000+00:00 46451 StateMachineSupervisor Recover Ion 60463.904674109 2024-06-02T21:42:43.843000+00:00 46491 switchBeam Beam: ABC 60463.904708588 2024-06-02T21:42:46.822000+00:00 46494 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60463.904805509 2024-06-02T21:42:55.196000+00:00 46495 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 13.0, ATT_SP (dB) = 23.0. 60463.904825301 2024-06-02T21:42:56.906000+00:00 46497 switchBeam Beam: B 60463.904848241 2024-06-02T21:42:58.888000+00:00 46498 MeasureFluorescenceLevels Bright : 58.2 +- 7.5, Dark : 0.2 +- 0.5, Threshold: int( ceil( 3.8 ) ) = 4, N_meas = 100, t_gate = 5.0 ms 60463.904856632 2024-06-02T21:42:59.613000+00:00 46451 StateMachineSupervisor Ion Bright, Start Clockrun 60463.904891956 2024-06-02T21:43:02.665000+00:00 46501 switchBeam Beam: B 60463.904902234 2024-06-02T21:43:03.553000+00:00 46502 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 411, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.00, 16.30, 15.57), att_RCDAT [dB] = 27.00, LCplus [V] = 1.8483, LCminus [V] = 3.2663 # End of file 60463_artiq_log.txt