# Start of file 60458_artiq_log.txt # First point: 60458.046860 2024-05-28T01:07:28.719000+00:00 # Last point: 60458.873108 2024-05-28T20:57:16.514000+00:00 # Num rows: 47 # File updated: 2024-05-29T07:41:37.952358 # Columns: MJD DATE RID PROGRAM MESSAGE 60458.046860173 2024-05-28T01:07:28.719000+00:00 45977 StateMachineSupervisor Ion Dark 60458.046866366 2024-05-28T01:07:29.254000+00:00 45977 StateMachineSupervisor Recover Ion 60458.046875093 2024-05-28T01:07:30.008000+00:00 45981 switchBeam Beam: ABC 60458.046910034 2024-05-28T01:07:33.027000+00:00 45984 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60458.047007951 2024-05-28T01:07:41.487000+00:00 45985 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60458.047027153 2024-05-28T01:07:43.146000+00:00 45987 switchBeam Beam: B 60458.047049919 2024-05-28T01:07:45.113000+00:00 45988 MeasureFluorescenceLevels Bright : 74.7 +- 9.4, Dark : 74.2 +- 9.1, Threshold: int( ceil( 74.5 ) ) = 75, N_meas = 100, t_gate = 5.0 ms 60458.047058600 2024-05-28T01:07:45.863000+00:00 45977 StateMachineSupervisor Ion Bright, Start Clockrun 60458.047093171 2024-05-28T01:07:48.850000+00:00 45991 switchBeam Beam: B 60458.047103484 2024-05-28T01:07:49.741000+00:00 45992 Lock_to_C124421 t_probe [us] = 320000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 219, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 109, (C1, C2, C4) att [dB] = (15.00, 16.30, 15.57), att_RCDAT [dB] = 31.00, LCplus [V] = 1.8483, LCminus [V] = 3.2663 60458.196940914 2024-05-28T04:43:35.695000+00:00 45994 SetCoolingAOM mode : umotion, AOM_f (MHz) : 207.5, ATT_Main (dB) = 9.0, ATT_SP (dB) = 19.0. 60458.198133704 2024-05-28T04:45:18.752000+00:00 45995 MicroMotionMeasurement3Beam Beam: A, N_photons: 600000, N_bins: 25, f_mod [MHz]: 14.418000, duration [s]: 99.046 60458.198153773 2024-05-28T04:45:20.486000+00:00 45996 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60458.198166342 2024-05-28T04:45:21.572000+00:00 45997 switchBeam Beam: B 60458.202829503 2024-05-28T04:52:04.469000+00:00 45999 SetAtt att_RCDAT : 28.0 dB 60458.202908461 2024-05-28T04:52:11.291000+00:00 46000 StateMachineSupervisor Start Clockrun 60458.202932511 2024-05-28T04:52:13.369000+00:00 46002 switchBeam Beam: B 60458.202944410 2024-05-28T04:52:14.397000+00:00 46003 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 411, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.00, 16.30, 15.57), att_RCDAT [dB] = 28.00, LCplus [V] = 1.8483, LCminus [V] = 3.2663 60458.539297303 2024-05-28T12:56:35.287000+00:00 46000 StateMachineSupervisor Ion Dark 60458.539303415 2024-05-28T12:56:35.815000+00:00 46000 StateMachineSupervisor Recover Ion 60458.539314259 2024-05-28T12:56:36.752000+00:00 46004 switchBeam Beam: ABC 60458.539347778 2024-05-28T12:56:39.648000+00:00 46007 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60458.539444479 2024-05-28T12:56:48.003000+00:00 46008 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60458.539463565 2024-05-28T12:56:49.652000+00:00 46010 switchBeam Beam: B 60458.539487060 2024-05-28T12:56:51.682000+00:00 46011 MeasureFluorescenceLevels Bright : 73.4 +- 8.9, Dark : 75.3 +- 9.1, Threshold: int( ceil( 74.4 ) ) = 75, N_meas = 100, t_gate = 5.0 ms 60458.539495463 2024-05-28T12:56:52.408000+00:00 46000 StateMachineSupervisor Ion Bright, Start Clockrun 60458.539529688 2024-05-28T12:56:55.365000+00:00 46014 switchBeam Beam: B 60458.539540614 2024-05-28T12:56:56.309000+00:00 46015 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 411, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.00, 16.30, 15.57), att_RCDAT [dB] = 28.00, LCplus [V] = 1.8483, LCminus [V] = 3.2663 60458.580639491 2024-05-28T13:56:07.252000+00:00 46017 SetAtt att_RCDAT : 59.0 dB 60458.582789525 2024-05-28T13:59:13.015000+00:00 46018 StateMachineSupervisor Start Clockrun 60458.582813148 2024-05-28T13:59:15.056000+00:00 46020 switchBeam Beam: B 60458.582823727 2024-05-28T13:59:15.970000+00:00 46021 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 411, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.00, 16.30, 15.57), att_RCDAT [dB] = 59.00, LCplus [V] = 1.8483, LCminus [V] = 3.2663 60458.583131459 2024-05-28T13:59:42.558000+00:00 46022 SetAtt att_RCDAT : 28.0 dB 60458.583169259 2024-05-28T13:59:45.824000+00:00 46024 StateMachineSupervisor Start Clockrun 60458.583193067 2024-05-28T13:59:47.881000+00:00 46026 switchBeam Beam: B 60458.583204398 2024-05-28T13:59:48.860000+00:00 46027 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 411, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.00, 16.30, 15.57), att_RCDAT [dB] = 28.00, LCplus [V] = 1.8483, LCminus [V] = 3.2663 60458.775274664 2024-05-28T18:36:23.731000+00:00 46028 SetAtt att_RCDAT : 27.0 dB 60458.872859433 2024-05-28T20:56:55.055000+00:00 46024 StateMachineSupervisor Ion Dark 60458.872865556 2024-05-28T20:56:55.584000+00:00 46024 StateMachineSupervisor Recover Ion 60458.872876123 2024-05-28T20:56:56.497000+00:00 46029 switchBeam Beam: ABC 60458.872909734 2024-05-28T20:56:59.401000+00:00 46032 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60458.873006146 2024-05-28T20:57:07.731000+00:00 46033 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60458.873026065 2024-05-28T20:57:09.452000+00:00 46035 switchBeam Beam: B 60458.873049549 2024-05-28T20:57:11.481000+00:00 46036 MeasureFluorescenceLevels Bright : 71.9 +- 9.0, Dark : 72.3 +- 7.9, Threshold: int( ceil( 72.1 ) ) = 73, N_meas = 100, t_gate = 5.0 ms 60458.873063495 2024-05-28T20:57:12.686000+00:00 46024 StateMachineSupervisor Ion Bright, Start Clockrun 60458.873096806 2024-05-28T20:57:15.564000+00:00 46039 switchBeam Beam: B 60458.873107801 2024-05-28T20:57:16.514000+00:00 46040 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 411, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.00, 16.30, 15.57), att_RCDAT [dB] = 27.00, LCplus [V] = 1.8483, LCminus [V] = 3.2663 # End of file 60458_artiq_log.txt