# Start of file 60437_artiq_log.txt # First point: 60437.217577 2024-05-07T05:13:18.675000+00:00 # Last point: 60437.886271 2024-05-07T21:16:13.772000+00:00 # Num rows: 47 # File updated: 2024-05-08T00:10:25.527806 # Columns: MJD DATE RID PROGRAM MESSAGE 60437.217577257 2024-05-07T05:13:18.675000+00:00 43357 StateMachineSupervisor Ion Dark 60437.217583391 2024-05-07T05:13:19.205000+00:00 43357 StateMachineSupervisor Recover Ion 60437.217592905 2024-05-07T05:13:20.027000+00:00 43373 switchBeam Beam: ABC 60437.217626076 2024-05-07T05:13:22.893000+00:00 43376 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60437.217724722 2024-05-07T05:13:31.416000+00:00 43377 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60437.217745914 2024-05-07T05:13:33.247000+00:00 43379 switchBeam Beam: B 60437.217769537 2024-05-07T05:13:35.288000+00:00 43380 MeasureFluorescenceLevels Bright : 80.7 +- 9.9, Dark : 0.5 +- 0.8, Threshold: int( ceil( 6.4 ) ) = 7, N_meas = 100, t_gate = 5.0 ms 60437.217781331 2024-05-07T05:13:36.307000+00:00 43357 StateMachineSupervisor Ion Bright, Start Clockrun 60437.217814919 2024-05-07T05:13:39.209000+00:00 43383 switchBeam Beam: B 60437.217825394 2024-05-07T05:13:40.114000+00:00 43384 Lock_to_C124421 t_probe [us] = 80000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 684, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 342, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 60437.368466748 2024-05-07T08:50:35.527000+00:00 43386 SetCoolingAOM mode : umotion, AOM_f (MHz) : 207.5, ATT_Main (dB) = 9.0, ATT_SP (dB) = 19.0. 60437.369783542 2024-05-07T08:52:29.298000+00:00 43387 MicroMotionMeasurement Beam: A, N_photons: 600000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 93.706 60437.371674965 2024-05-07T08:55:12.717000+00:00 43388 switchBeam Beam: B 60437.372047454 2024-05-07T08:55:44.900000+00:00 43389 SetAtt att_RCDAT : 28.0 dB 60437.372126898 2024-05-07T08:55:51.764000+00:00 43390 StateMachineSupervisor Start Clockrun 60437.372152465 2024-05-07T08:55:53.973000+00:00 43392 switchBeam Beam: B 60437.372161863 2024-05-07T08:55:54.785000+00:00 43393 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 393, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 197, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 28.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 60437.419561991 2024-05-07T10:04:10.156000+00:00 43395 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60437.419583056 2024-05-07T10:04:11.976000+00:00 43396 StateMachineSupervisor Start Clockrun 60437.419607755 2024-05-07T10:04:14.110000+00:00 43398 switchBeam Beam: B 60437.419618703 2024-05-07T10:04:15.056000+00:00 43399 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 393, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 197, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 28.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 60437.527843958 2024-05-07T12:40:05.718000+00:00 43402 StateMachineSupervisor Start Clockrun 60437.527867963 2024-05-07T12:40:07.792000+00:00 43404 switchBeam Beam: B 60437.527880347 2024-05-07T12:40:08.862000+00:00 43405 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 393, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 197, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 28.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 60437.572847535 2024-05-07T13:44:54.027000+00:00 43408 StateMachineSupervisor Start Clockrun 60437.572871852 2024-05-07T13:44:56.128000+00:00 43410 switchBeam Beam: B 60437.572883461 2024-05-07T13:44:57.131000+00:00 43411 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 393, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 197, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 28.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 60437.597413137 2024-05-07T14:20:16.495000+00:00 43408 StateMachineSupervisor Ion Dark 60437.597419144 2024-05-07T14:20:17.014000+00:00 43408 StateMachineSupervisor Recover Ion 60437.597428658 2024-05-07T14:20:17.836000+00:00 43412 switchBeam Beam: ABC 60437.597462025 2024-05-07T14:20:20.719000+00:00 43415 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60437.597560151 2024-05-07T14:20:29.197000+00:00 43416 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60437.597578438 2024-05-07T14:20:30.777000+00:00 43418 switchBeam Beam: B 60437.597602465 2024-05-07T14:20:32.853000+00:00 43419 MeasureFluorescenceLevels Bright : 83.1 +- 8.2, Dark : 0.5 +- 0.7, Threshold: int( ceil( 6.2 ) ) = 7, N_meas = 100, t_gate = 5.0 ms 60437.597611296 2024-05-07T14:20:33.616000+00:00 43408 StateMachineSupervisor Ion Bright, Start Clockrun 60437.597644572 2024-05-07T14:20:36.491000+00:00 43422 switchBeam Beam: B 60437.597655127 2024-05-07T14:20:37.403000+00:00 43423 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 393, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 197, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 28.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 60437.886026944 2024-05-07T21:15:52.728000+00:00 43408 StateMachineSupervisor Ion Dark 60437.886032986 2024-05-07T21:15:53.250000+00:00 43408 StateMachineSupervisor Recover Ion 60437.886041644 2024-05-07T21:15:53.998000+00:00 43424 switchBeam Beam: ABC 60437.886074988 2024-05-07T21:15:56.879000+00:00 43427 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60437.886174005 2024-05-07T21:16:05.434000+00:00 43428 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60437.886192477 2024-05-07T21:16:07.030000+00:00 43430 switchBeam Beam: B 60437.886216227 2024-05-07T21:16:09.082000+00:00 43431 MeasureFluorescenceLevels Bright : 80.7 +- 10.0, Dark : 0.5 +- 0.7, Threshold: int( ceil( 6.5 ) ) = 7, N_meas = 100, t_gate = 5.0 ms 60437.886225243 2024-05-07T21:16:09.861000+00:00 43408 StateMachineSupervisor Ion Bright, Start Clockrun 60437.886259224 2024-05-07T21:16:12.797000+00:00 43434 switchBeam Beam: B 60437.886270509 2024-05-07T21:16:13.772000+00:00 43435 Lock_to_C124421 t_probe [us] = 160000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 393, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 197, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 28.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 # End of file 60437_artiq_log.txt