# Start of file 60435_artiq_log.txt # First point: 60435.169302 2024-05-05T04:03:47.698000+00:00 # Last point: 60435.716460 2024-05-05T17:11:42.126000+00:00 # Num rows: 48 # File updated: 2024-05-06T00:10:29.608498 # Columns: MJD DATE RID PROGRAM MESSAGE 60435.169302060 2024-05-05T04:03:47.698000+00:00 43068 StateMachineSupervisor Ion Dark 60435.169308171 2024-05-05T04:03:48.226000+00:00 43068 StateMachineSupervisor Recover Ion 60435.169318310 2024-05-05T04:03:49.102000+00:00 43108 switchBeam Beam: ABC 60435.169352269 2024-05-05T04:03:52.036000+00:00 43111 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60435.169448877 2024-05-05T04:04:00.383000+00:00 43112 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60435.169469491 2024-05-05T04:04:02.164000+00:00 43114 switchBeam Beam: B 60435.169493090 2024-05-05T04:04:04.203000+00:00 43115 MeasureFluorescenceLevels Bright : 76.7 +- 9.2, Dark : 0.4 +- 0.6, Threshold: int( ceil( 5.4 ) ) = 6, N_meas = 100, t_gate = 5.0 ms 60435.169506076 2024-05-05T04:04:05.325000+00:00 43068 StateMachineSupervisor Ion Bright, Start Clockrun 60435.169540648 2024-05-05T04:04:08.312000+00:00 43118 switchBeam Beam: B 60435.169551146 2024-05-05T04:04:09.219000+00:00 43119 Lock_to_C124421 t_probe [us] = 80000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 684, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 342, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 60435.209599386 2024-05-05T05:01:49.387000+00:00 43068 StateMachineSupervisor Ion Dark 60435.209605521 2024-05-05T05:01:49.917000+00:00 43068 StateMachineSupervisor Recover Ion 60435.209616632 2024-05-05T05:01:50.877000+00:00 43120 switchBeam Beam: ABC 60435.209650370 2024-05-05T05:01:53.792000+00:00 43123 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60435.209746297 2024-05-05T05:02:02.080000+00:00 43124 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60435.209765150 2024-05-05T05:02:03.709000+00:00 43126 switchBeam Beam: B 60435.209788345 2024-05-05T05:02:05.713000+00:00 43127 MeasureFluorescenceLevels Bright : 76.7 +- 7.7, Dark : 0.4 +- 0.7, Threshold: int( ceil( 5.7 ) ) = 6, N_meas = 100, t_gate = 5.0 ms 60435.209797674 2024-05-05T05:02:06.519000+00:00 43068 StateMachineSupervisor Ion Bright, Start Clockrun 60435.209832060 2024-05-05T05:02:09.490000+00:00 43130 switchBeam Beam: B 60435.209842569 2024-05-05T05:02:10.398000+00:00 43131 Lock_to_C124421 t_probe [us] = 80000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 684, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 342, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 60435.338434584 2024-05-05T08:07:20.748000+00:00 43132 SetCoolingAOM mode : umotion, AOM_f (MHz) : 207.5, ATT_Main (dB) = 9.0, ATT_SP (dB) = 19.0. 60435.339582245 2024-05-05T08:08:59.906000+00:00 43134 MicroMotionMeasurement Beam: A, N_photons: 600000, N_bins: 25, f_mod [MHz]: 14.420000, duration [s]: 93.681 60435.339682963 2024-05-05T08:09:08.608000+00:00 43135 SetLockFreqs Linecenter [MHz AOM]: 75.559903, abs(B) [uT]: 4.796560000, EQS C1, C2, C4 [Hz]: 0.0, 0.0, 0.0 60435.339792951 2024-05-05T08:09:18.111000+00:00 43136 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60435.339852164 2024-05-05T08:09:23.227000+00:00 43137 switchBeam Beam: B 60435.339877916 2024-05-05T08:09:25.452000+00:00 43138 StateMachineSupervisor Start Clockrun 60435.339901979 2024-05-05T08:09:27.531000+00:00 43140 switchBeam Beam: B 60435.339912246 2024-05-05T08:09:28.418000+00:00 43141 Lock_to_C124421 t_probe [us] = 80000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 684, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 342, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 60435.474757442 2024-05-05T11:23:39.043000+00:00 43138 StateMachineSupervisor Ion Dark 60435.474763530 2024-05-05T11:23:39.569000+00:00 43138 StateMachineSupervisor Recover Ion 60435.474773507 2024-05-05T11:23:40.431000+00:00 43142 switchBeam Beam: ABC 60435.474807118 2024-05-05T11:23:43.335000+00:00 43145 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60435.474904213 2024-05-05T11:23:51.724000+00:00 43146 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60435.474923067 2024-05-05T11:23:53.353000+00:00 43148 switchBeam Beam: B 60435.474946817 2024-05-05T11:23:55.405000+00:00 43149 MeasureFluorescenceLevels Bright : 81.2 +- 10.0, Dark : 0.4 +- 0.6, Threshold: int( ceil( 5.8 ) ) = 6, N_meas = 100, t_gate = 5.0 ms 60435.474955845 2024-05-05T11:23:56.185000+00:00 43138 StateMachineSupervisor Ion Bright, Start Clockrun 60435.474989526 2024-05-05T11:23:59.095000+00:00 43152 switchBeam Beam: B 60435.475000556 2024-05-05T11:24:00.048000+00:00 43153 Lock_to_C124421 t_probe [us] = 80000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 684, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 342, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 60435.716208981 2024-05-05T17:11:20.456000+00:00 43138 StateMachineSupervisor Ion Dark 60435.716215069 2024-05-05T17:11:20.982000+00:00 43138 StateMachineSupervisor Recover Ion 60435.716223680 2024-05-05T17:11:21.726000+00:00 43154 switchBeam Beam: ABC 60435.716256308 2024-05-05T17:11:24.545000+00:00 43157 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60435.716358692 2024-05-05T17:11:33.391000+00:00 43158 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60435.716377280 2024-05-05T17:11:34.997000+00:00 43160 switchBeam Beam: B 60435.716400116 2024-05-05T17:11:36.970000+00:00 43161 MeasureFluorescenceLevels Bright : 79.4 +- 9.1, Dark : 0.3 +- 0.6, Threshold: int( ceil( 5.1 ) ) = 6, N_meas = 100, t_gate = 5.0 ms 60435.716412951 2024-05-05T17:11:38.079000+00:00 43138 StateMachineSupervisor Ion Bright, Start Clockrun 60435.716447894 2024-05-05T17:11:41.098000+00:00 43164 switchBeam Beam: B 60435.716459792 2024-05-05T17:11:42.126000+00:00 43165 Lock_to_C124421 t_probe [us] = 80000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 684, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 342, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 # End of file 60435_artiq_log.txt