# Start of file 60428_artiq_log.txt # First point: 60428.045155 2024-04-28T01:05:01.423000+00:00 # Last point: 60428.900392 2024-04-28T21:36:33.840000+00:00 # Num rows: 65 # File updated: 2024-04-29T00:10:21.206913 # Columns: MJD DATE RID PROGRAM MESSAGE 60428.045155359 2024-04-28T01:05:01.423000+00:00 42133 StateMachineSupervisor Ion Dark 60428.045161458 2024-04-28T01:05:01.950000+00:00 42133 StateMachineSupervisor Recover Ion 60428.045171667 2024-04-28T01:05:02.832000+00:00 42137 switchBeam Beam: ABC 60428.045204930 2024-04-28T01:05:05.706000+00:00 42140 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60428.045301644 2024-04-28T01:05:14.062000+00:00 42141 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60428.045320741 2024-04-28T01:05:15.712000+00:00 42143 switchBeam Beam: B 60428.045346053 2024-04-28T01:05:17.899000+00:00 42144 MeasureFluorescenceLevels Bright : 81.7 +- 8.2, Dark : 0.5 +- 0.8, Threshold: int( ceil( 6.3 ) ) = 7, N_meas = 100, t_gate = 5.0 ms 60428.045359398 2024-04-28T01:05:19.052000+00:00 42133 StateMachineSupervisor Ion Bright, Start Clockrun 60428.045393287 2024-04-28T01:05:21.980000+00:00 42147 switchBeam Beam: B 60428.045403484 2024-04-28T01:05:22.861000+00:00 42148 Lock_to_C124421 t_probe [us] = 136000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 453, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 226, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 26.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 60428.177538970 2024-04-28T04:15:39.367000+00:00 42150 SetCoolingAOM mode : umotion, AOM_f (MHz) : 211.0, ATT_Main (dB) = 9.0, ATT_SP (dB) = 19.0. 60428.178480903 2024-04-28T04:17:00.750000+00:00 42151 MicroMotionMeasurement Beam: A, N_photons: 600000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 77.740 60428.178502604 2024-04-28T04:17:02.625000+00:00 42152 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60428.178514653 2024-04-28T04:17:03.666000+00:00 42153 switchBeam Beam: B 60428.178515463 2024-04-28T04:17:03.736000+00:00 42154 SetAtt att_RCDAT : 27.0 dB 60428.178554572 2024-04-28T04:17:07.115000+00:00 42155 StateMachineSupervisor Start Clockrun 60428.178580591 2024-04-28T04:17:09.363000+00:00 42157 switchBeam Beam: B 60428.178591724 2024-04-28T04:17:10.325000+00:00 42158 Lock_to_C124421 t_probe [us] = 171000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 372, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 187, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 27.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 60428.388872674 2024-04-28T09:19:58.599000+00:00 42155 StateMachineSupervisor Ion Dark 60428.388878762 2024-04-28T09:19:59.125000+00:00 42155 StateMachineSupervisor Recover Ion 60428.388888623 2024-04-28T09:19:59.977000+00:00 42159 switchBeam Beam: ABC 60428.388921597 2024-04-28T09:20:02.826000+00:00 42162 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60428.389019456 2024-04-28T09:20:11.281000+00:00 42163 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60428.389037384 2024-04-28T09:20:12.830000+00:00 42165 switchBeam Beam: B 60428.389061018 2024-04-28T09:20:14.872000+00:00 42166 MeasureFluorescenceLevels Bright : 82.5 +- 10.5, Dark : 0.4 +- 0.7, Threshold: int( ceil( 6.0 ) ) = 6, N_meas = 100, t_gate = 5.0 ms 60428.389070972 2024-04-28T09:20:15.732000+00:00 42155 StateMachineSupervisor Ion Bright, Start Clockrun 60428.389105451 2024-04-28T09:20:18.711000+00:00 42169 switchBeam Beam: B 60428.389115787 2024-04-28T09:20:19.604000+00:00 42170 Lock_to_C124421 t_probe [us] = 171000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 372, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 187, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 27.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 60428.540869109 2024-04-28T12:58:51.091000+00:00 42155 StateMachineSupervisor Ion Dark 60428.540875139 2024-04-28T12:58:51.612000+00:00 42155 StateMachineSupervisor Recover Ion 60428.540883623 2024-04-28T12:58:52.345000+00:00 42171 switchBeam Beam: ABC 60428.540917245 2024-04-28T12:58:55.250000+00:00 42174 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60428.541015544 2024-04-28T12:59:03.743000+00:00 42175 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60428.541034479 2024-04-28T12:59:05.379000+00:00 42177 switchBeam Beam: B 60428.541058669 2024-04-28T12:59:07.469000+00:00 42178 MeasureFluorescenceLevels Bright : 84.6 +- 8.9, Dark : 0.5 +- 0.7, Threshold: int( ceil( 6.2 ) ) = 7, N_meas = 100, t_gate = 5.0 ms 60428.541067176 2024-04-28T12:59:08.204000+00:00 42155 StateMachineSupervisor Ion Bright, Start Clockrun 60428.541101077 2024-04-28T12:59:11.133000+00:00 42181 switchBeam Beam: B 60428.541112836 2024-04-28T12:59:12.149000+00:00 42182 Lock_to_C124421 t_probe [us] = 171000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 372, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 187, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 27.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 60428.631452025 2024-04-28T15:09:17.455000+00:00 42155 StateMachineSupervisor Ion Dark 60428.631458032 2024-04-28T15:09:17.974000+00:00 42155 StateMachineSupervisor Recover Ion 60428.631467327 2024-04-28T15:09:18.777000+00:00 42183 switchBeam Beam: ABC 60428.631500752 2024-04-28T15:09:21.665000+00:00 42186 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60428.631600231 2024-04-28T15:09:30.260000+00:00 42187 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60428.631619410 2024-04-28T15:09:31.917000+00:00 42189 switchBeam Beam: B 60428.631643599 2024-04-28T15:09:34.007000+00:00 42190 MeasureFluorescenceLevels Bright : 83.9 +- 8.7, Dark : 0.5 +- 0.6, Threshold: int( ceil( 6.5 ) ) = 7, N_meas = 100, t_gate = 5.0 ms 60428.631655938 2024-04-28T15:09:35.073000+00:00 42155 StateMachineSupervisor Ion Bright, Start Clockrun 60428.631688715 2024-04-28T15:09:37.905000+00:00 42193 switchBeam Beam: B 60428.631699433 2024-04-28T15:09:38.831000+00:00 42194 Lock_to_C124421 t_probe [us] = 171000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 372, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 187, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 27.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 60428.656041412 2024-04-28T15:44:41.978000+00:00 42196 SetCoolingAOM mode : umotion, AOM_f (MHz) : 211.0, ATT_Main (dB) = 9.0, ATT_SP (dB) = 19.0. 60428.656970555 2024-04-28T15:46:02.256000+00:00 42197 MicroMotionMeasurement Beam: A, N_photons: 600000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 76.831 60428.656993449 2024-04-28T15:46:04.234000+00:00 42198 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60428.657006342 2024-04-28T15:46:05.348000+00:00 42199 switchBeam Beam: B 60428.657036852 2024-04-28T15:46:07.984000+00:00 42200 StateMachineSupervisor Start Clockrun 60428.657066875 2024-04-28T15:46:10.578000+00:00 42202 switchBeam Beam: B 60428.657079699 2024-04-28T15:46:11.686000+00:00 42203 Lock_to_C124421 t_probe [us] = 171000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 372, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 187, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 27.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 60428.900147072 2024-04-28T21:36:12.707000+00:00 42200 StateMachineSupervisor Ion Dark 60428.900153067 2024-04-28T21:36:13.225000+00:00 42200 StateMachineSupervisor Recover Ion 60428.900162569 2024-04-28T21:36:14.046000+00:00 42204 switchBeam Beam: ABC 60428.900195475 2024-04-28T21:36:16.889000+00:00 42207 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60428.900293252 2024-04-28T21:36:25.337000+00:00 42208 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 211.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60428.900312153 2024-04-28T21:36:26.970000+00:00 42210 switchBeam Beam: B 60428.900335636 2024-04-28T21:36:28.999000+00:00 42211 MeasureFluorescenceLevels Bright : 83.4 +- 9.1, Dark : 0.5 +- 0.7, Threshold: int( ceil( 6.5 ) ) = 7, N_meas = 100, t_gate = 5.0 ms 60428.900345208 2024-04-28T21:36:29.826000+00:00 42200 StateMachineSupervisor Ion Bright, Start Clockrun 60428.900381042 2024-04-28T21:36:32.922000+00:00 42214 switchBeam Beam: B 60428.900391667 2024-04-28T21:36:33.840000+00:00 42215 Lock_to_C124421 t_probe [us] = 171000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 372, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 187, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 27.00, LCplus [V] = 1.8459, LCminus [V] = 3.2778 # End of file 60428_artiq_log.txt