# Start of file 60399_artiq_log.txt # First point: 60399.024899 2024-03-30T00:35:51.290000+00:00 # Last point: 60399.830672 2024-03-30T19:56:10.091000+00:00 # Num rows: 40 # File updated: 2024-03-31T01:00:26.258835 # Columns: MJD DATE RID PROGRAM MESSAGE 60399.024899190 2024-03-30T00:35:51.290000+00:00 38859 StateMachineSupervisor Ion Dark 60399.024905290 2024-03-30T00:35:51.817000+00:00 38859 StateMachineSupervisor Recover Ion 60399.024919028 2024-03-30T00:35:53.004000+00:00 38972 switchBeam Beam: ABC 60399.024960405 2024-03-30T00:35:56.579000+00:00 38975 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60399.025049560 2024-03-30T00:36:04.282000+00:00 38976 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 208.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60399.025073264 2024-03-30T00:36:06.330000+00:00 38978 switchBeam Beam: B 60399.025097292 2024-03-30T00:36:08.406000+00:00 38979 MeasureFluorescenceLevels Bright : 39.5 +- 5.7, Dark : 0.2 +- 0.4, Threshold: int( ceil( 2.5 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60399.025109062 2024-03-30T00:36:09.423000+00:00 38859 StateMachineSupervisor Ion Bright, Start Clockrun 60399.025153380 2024-03-30T00:36:13.252000+00:00 38982 switchBeam Beam: B 60399.025167697 2024-03-30T00:36:14.489000+00:00 38983 Lock_to_C124421 t_probe [us] = 141000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 438, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 219, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8555, LCminus [V] = 3.3082 60399.279342674 2024-03-30T06:42:15.207000+00:00 38859 StateMachineSupervisor Ion Dark 60399.279348669 2024-03-30T06:42:15.725000+00:00 38859 StateMachineSupervisor Recover Ion 60399.279359861 2024-03-30T06:42:16.692000+00:00 38984 switchBeam Beam: ABC 60399.279398924 2024-03-30T06:42:20.067000+00:00 38987 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60399.279493021 2024-03-30T06:42:28.197000+00:00 38988 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 208.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60399.279513623 2024-03-30T06:42:29.977000+00:00 38990 switchBeam Beam: B 60399.279537500 2024-03-30T06:42:32.040000+00:00 38991 MeasureFluorescenceLevels Bright : 40.5 +- 5.9, Dark : 0.2 +- 0.5, Threshold: int( ceil( 3.1 ) ) = 4, N_meas = 100, t_gate = 5.0 ms 60399.279552269 2024-03-30T06:42:33.316000+00:00 38859 StateMachineSupervisor Ion Bright, Start Clockrun 60399.279593588 2024-03-30T06:42:36.886000+00:00 38994 switchBeam Beam: B 60399.279604190 2024-03-30T06:42:37.802000+00:00 38995 Lock_to_C124421 t_probe [us] = 141000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 438, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 219, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8555, LCminus [V] = 3.3082 60399.699372894 2024-03-30T16:47:05.818000+00:00 38859 StateMachineSupervisor Ion Dark 60399.699378877 2024-03-30T16:47:06.335000+00:00 38859 StateMachineSupervisor Recover Ion 60399.699392095 2024-03-30T16:47:07.477000+00:00 38996 switchBeam Beam: ABC 60399.699430312 2024-03-30T16:47:10.779000+00:00 38999 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60399.699522315 2024-03-30T16:47:18.728000+00:00 39000 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 208.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60399.699543947 2024-03-30T16:47:20.597000+00:00 39002 switchBeam Beam: B 60399.699572072 2024-03-30T16:47:23.027000+00:00 39003 MeasureFluorescenceLevels Bright : 40.2 +- 6.8, Dark : 0.2 +- 0.5, Threshold: int( ceil( 3.0 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60399.699582488 2024-03-30T16:47:23.927000+00:00 38859 StateMachineSupervisor Ion Bright, Start Clockrun 60399.699626956 2024-03-30T16:47:27.769000+00:00 39006 switchBeam Beam: B 60399.699643484 2024-03-30T16:47:29.197000+00:00 39007 Lock_to_C124421 t_probe [us] = 141000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 438, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 219, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8555, LCminus [V] = 3.3082 60399.830408357 2024-03-30T19:55:47.282000+00:00 38859 StateMachineSupervisor Ion Dark 60399.830414479 2024-03-30T19:55:47.811000+00:00 38859 StateMachineSupervisor Recover Ion 60399.830429757 2024-03-30T19:55:49.131000+00:00 39008 switchBeam Beam: ABC 60399.830469340 2024-03-30T19:55:52.551000+00:00 39011 SetCoolingAOM mode : recovery, AOM_f (MHz) : 180.0, ATT_Main (dB) = 5.0, ATT_SP (dB) = 12.0. 60399.830557095 2024-03-30T19:56:00.133000+00:00 39012 SetCoolingAOM mode : clockrun, AOM_f (MHz) : 208.0, ATT_Main (dB) = 12.0, ATT_SP (dB) = 22.0. 60399.830582616 2024-03-30T19:56:02.338000+00:00 39014 switchBeam Beam: B 60399.830605139 2024-03-30T19:56:04.284000+00:00 39015 MeasureFluorescenceLevels Bright : 42.9 +- 6.9, Dark : 0.3 +- 0.5, Threshold: int( ceil( 3.6 ) ) = 4, N_meas = 100, t_gate = 5.0 ms 60399.830618194 2024-03-30T19:56:05.412000+00:00 38859 StateMachineSupervisor Ion Bright, Start Clockrun 60399.830655567 2024-03-30T19:56:08.641000+00:00 39018 switchBeam Beam: B 60399.830672350 2024-03-30T19:56:10.091000+00:00 39019 Lock_to_C124421 t_probe [us] = 141000, n_shots = 1, g1 = 0.3, T_drift_s = 600.0, N_drift = 438, pmt_thr = 7, T_p0avg_s = 900.0, N_p0avg = 219, (C1, C2, C4) att [dB] = (15.00, 15.86, 15.57), att_RCDAT [dB] = 25.00, LCplus [V] = 1.8555, LCminus [V] = 3.3082 # End of file 60399_artiq_log.txt