# Start of file 60369_artiq_log.txt # First point: 60369.242833 2024-02-29T05:49:40.751000+00:00 # Last point: 60369.630139 2024-02-29T15:07:23.986000+00:00 # Num rows: 73 # File updated: 2024-03-01T01:11:12.204704 # Columns: MJD DATE RID PROGRAM MESSAGE 60369.242832766 2024-02-29T05:49:40.751000+00:00 35908 MeasureFluorescenceLevels Bright : 1.7 +- 1.3, Dark : 1.5 +- 1.1, Threshold: int( ceil( 1.6 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60369.242959190 2024-02-29T05:49:51.674000+00:00 35910 MeasureFluorescenceLevels Bright : 3.1 +- 2.0, Dark : 2.6 +- 1.7, Threshold: int( ceil( 2.9 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60369.243125034 2024-02-29T05:50:06.003000+00:00 35912 MeasureFluorescenceLevels Bright : 321.3 +- 15.2, Dark : 103.1 +- 9.2, Threshold: int( ceil( 182.0 ) ) = 182, N_meas = 100, t_gate = 5.0 ms 60369.243266840 2024-02-29T05:50:18.255000+00:00 35914 switchBeam Beam: B 60369.243318843 2024-02-29T05:50:22.748000+00:00 35915 MeasureFluorescenceLevels Bright : 47.3 +- 6.4, Dark : 0.5 +- 0.8, Threshold: int( ceil( 4.7 ) ) = 5, N_meas = 100, t_gate = 5.0 ms 60369.243751875 2024-02-29T05:51:00.162000+00:00 35916 MicroMotionMeasurement Beam: A, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 18.029 60369.243926042 2024-02-29T05:51:15.210000+00:00 35917 MicroMotionMeasurement Beam: B, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 15.035 60369.244040833 2024-02-29T05:51:25.128000+00:00 35918 MicroMotionMeasurement Beam: C, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 9.906 60369.245127384 2024-02-29T05:52:59.006000+00:00 35919 MicroMotionMinimizer N_photons: 100000, Initial (V12cm, V12diff, V34cm, V34diff) [V]: (-6.084000, 0.236670, 18.320256, 81.111966)num_iterations: 20, simplex_size [V]: 0.200, 60369.264574236 2024-02-29T06:20:59.214000+00:00 35920 MicroMotionMeasurement Beam: A, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 18.404 60369.264750475 2024-02-29T06:21:14.441000+00:00 35921 MicroMotionMeasurement Beam: B, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 15.215 60369.264866273 2024-02-29T06:21:24.446000+00:00 35922 MicroMotionMeasurement Beam: C, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 9.993 60369.264878507 2024-02-29T06:21:25.503000+00:00 35923 switchBeam Beam: B 60369.265103507 2024-02-29T06:21:44.943000+00:00 35924 MeasureFluorescenceLevels Bright : 45.3 +- 7.2, Dark : 0.3 +- 0.6, Threshold: int( ceil( 3.9 ) ) = 4, N_meas = 100, t_gate = 5.0 ms 60369.265349051 2024-02-29T06:22:06.158000+00:00 35925 SetAtt att_RCDAT : 16.0 dB 60369.265499502 2024-02-29T06:22:19.157000+00:00 35926 Lock_to_C124 t_probe [us] = 15000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1647, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 274, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8539, LCminus [V] = 3.2892 60369.267228079 2024-02-29T06:24:48.506000+00:00 35927 SetAtt att_RCDAT : 19.0 dB 60369.267245648 2024-02-29T06:24:50.024000+00:00 35928 Lock_to_C124 t_probe [us] = 30000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1239, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8539, LCminus [V] = 3.2892 60369.316381343 2024-02-29T07:35:35.348000+00:00 35930 MeasureFluorescenceLevels Bright : 1.7 +- 1.2, Dark : 1.6 +- 1.3, Threshold: int( ceil( 1.6 ) ) = 2, N_meas = 100, t_gate = 5.0 ms 60369.316502871 2024-02-29T07:35:45.848000+00:00 35932 MeasureFluorescenceLevels Bright : 66.0 +- 7.2, Dark : 66.0 +- 7.6, Threshold: int( ceil( 66.0 ) ) = 66, N_meas = 100, t_gate = 5.0 ms 60369.316652210 2024-02-29T07:35:58.751000+00:00 35934 MeasureFluorescenceLevels Bright : 102.9 +- 10.3, Dark : 102.6 +- 9.5, Threshold: int( ceil( 102.7 ) ) = 103, N_meas = 100, t_gate = 5.0 ms 60369.316875961 2024-02-29T07:36:18.083000+00:00 35936 MeasureFluorescenceLevels Bright : 105.5 +- 11.2, Dark : 105.4 +- 11.3, Threshold: int( ceil( 105.5 ) ) = 106, N_meas = 100, t_gate = 5.0 ms 60369.317217743 2024-02-29T07:36:47.613000+00:00 35937 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 100.0 60369.317325046 2024-02-29T07:36:56.884000+00:00 35938 MeasureFluorescenceLevels Bright : 105.7 +- 9.2, Dark : 105.3 +- 10.8, Threshold: int( ceil( 105.5 ) ) = 106, N_meas = 100, t_gate = 5.0 ms 60369.317635637 2024-02-29T07:37:23.719000+00:00 35939 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 100.0 60369.318047535 2024-02-29T07:37:59.307000+00:00 35940 MeasureFluorescenceLevels Bright : 104.7 +- 10.3, Dark : 104.5 +- 11.1, Threshold: int( ceil( 104.6 ) ) = 105, N_meas = 100, t_gate = 5.0 ms 60369.318285718 2024-02-29T07:38:19.886000+00:00 35941 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 100.0 60369.318475799 2024-02-29T07:38:36.309000+00:00 35943 MeasureFluorescenceLevels Bright : 105.9 +- 10.5, Dark : 105.3 +- 10.3, Threshold: int( ceil( 105.6 ) ) = 106, N_meas = 100, t_gate = 5.0 ms 60369.318801632 2024-02-29T07:39:04.461000+00:00 35945 MeasureFluorescenceLevels Bright : 98.8 +- 10.9, Dark : 99.8 +- 9.3, Threshold: int( ceil( 99.3 ) ) = 100, N_meas = 100, t_gate = 5.0 ms 60369.319057812 2024-02-29T07:39:26.595000+00:00 35946 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 100.0 60369.319428391 2024-02-29T07:39:58.613000+00:00 35947 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 100.0 60369.323057570 2024-02-29T07:45:12.174000+00:00 35948 MeasureFluorescenceLevels Bright : 98.8 +- 9.8, Dark : 100.3 +- 9.1, Threshold: int( ceil( 99.5 ) ) = 100, N_meas = 100, t_gate = 5.0 ms 60369.323326782 2024-02-29T07:45:35.434000+00:00 35949 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 100.0 60369.323563206 2024-02-29T07:45:55.861000+00:00 35951 MeasureFluorescenceLevels Bright : 18.6 +- 4.9, Dark : 19.4 +- 4.9, Threshold: int( ceil( 19.0 ) ) = 19, N_meas = 100, t_gate = 5.0 ms 60369.327544768 2024-02-29T07:51:39.868000+00:00 35952 MeasureFluorescenceLevels Bright : 18.0 +- 4.4, Dark : 18.3 +- 4.5, Threshold: int( ceil( 18.1 ) ) = 19, N_meas = 100, t_gate = 5.0 ms 60369.327785081 2024-02-29T07:52:00.631000+00:00 35953 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 100.0 60369.328849005 2024-02-29T07:53:32.554000+00:00 35954 MeasureFluorescenceLevels Bright : 18.4 +- 3.6, Dark : 18.2 +- 4.1, Threshold: int( ceil( 18.3 ) ) = 19, N_meas = 100, t_gate = 5.0 ms 60369.329102604 2024-02-29T07:53:54.465000+00:00 35956 MeasureFluorescenceLevels Bright : 19.1 +- 4.4, Dark : 18.5 +- 4.2, Threshold: int( ceil( 18.8 ) ) = 19, N_meas = 100, t_gate = 5.0 ms 60369.329344085 2024-02-29T07:54:15.329000+00:00 35958 MeasureFluorescenceLevels Bright : 18.9 +- 4.3, Dark : 18.9 +- 5.0, Threshold: int( ceil( 18.9 ) ) = 19, N_meas = 100, t_gate = 5.0 ms 60369.338606863 2024-02-29T08:07:35.633000+00:00 35959 MeasureFluorescenceLevels Bright : 19.9 +- 3.8, Dark : 19.6 +- 4.1, Threshold: int( ceil( 19.8 ) ) = 20, N_meas = 100, t_gate = 5.0 ms 60369.341244676 2024-02-29T08:11:23.540000+00:00 35960 MeasureFluorescenceLevels Bright : 18.5 +- 4.8, Dark : 18.9 +- 3.8, Threshold: int( ceil( 18.7 ) ) = 19, N_meas = 100, t_gate = 5.0 ms 60369.343565695 2024-02-29T08:14:44.076000+00:00 35961 MeasureFluorescenceLevels Bright : 19.5 +- 4.2, Dark : 19.6 +- 4.4, Threshold: int( ceil( 19.5 ) ) = 20, N_meas = 100, t_gate = 5.0 ms 60369.354070752 2024-02-29T08:29:51.713000+00:00 35962 switchBeam Beam: B 60369.354283715 2024-02-29T08:30:10.113000+00:00 35963 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 100.0 60369.357704271 2024-02-29T08:35:05.649000+00:00 35965 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 100.0 60369.400840301 2024-02-29T09:37:12.602000+00:00 35972 switchBeam Beam: B 60369.400936215 2024-02-29T09:37:20.889000+00:00 35973 MeasureFluorescenceLevels Bright : 44.1 +- 6.8, Dark : 0.3 +- 0.5, Threshold: int( ceil( 3.5 ) ) = 4, N_meas = 100, t_gate = 5.0 ms 60369.401745706 2024-02-29T09:38:30.829000+00:00 35974 MicroMotionMeasurement Beam: A, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 17.817 60369.401924491 2024-02-29T09:38:46.276000+00:00 35975 MicroMotionMeasurement Beam: B, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 15.433 60369.402045521 2024-02-29T09:38:56.733000+00:00 35976 MicroMotionMeasurement Beam: C, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 10.445 60369.405730984 2024-02-29T09:44:15.157000+00:00 35977 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 220.000, num_pts: 200, t_gate (ms) = 100.0 60369.405743218 2024-02-29T09:44:16.214000+00:00 35978 switchBeam Beam: A 60369.409108148 2024-02-29T09:49:06.944000+00:00 35979 ScanLCFit LCplus start [V]: 1.700, LCplus stop [V]: 2.100, num_points: 100, LCminus start [V]: 2.600, LCminus stop [V]: 4.500, num_points: 100, t_gate [ms]: 1000, 60369.409124525 2024-02-29T09:49:08.359000+00:00 35980 switchBeam Beam: B 60369.410057210 2024-02-29T09:50:28.943000+00:00 35981 SetAtt att_RCDAT : 16.0 dB 60369.410121736 2024-02-29T09:50:34.518000+00:00 35982 Lock_to_C124 t_probe [us] = 15000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1647, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 274, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8483, LCminus [V] = 3.2740 60369.411200590 2024-02-29T09:52:07.731000+00:00 35983 SetAtt att_RCDAT : 6.0 dB 60369.411219769 2024-02-29T09:52:09.388000+00:00 35984 Lock_to_C124 t_probe [us] = 1500, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 2343, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 390, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8483, LCminus [V] = 3.2740 60369.411769398 2024-02-29T09:52:56.876000+00:00 35985 SetLockFreqs Linecenter [MHz AOM]: 75.559124, abs(B) [uT]: 4.790000000, EQS C1, C2, C4 [Hz]: 0.0, 0.0, 0.0 60369.411788079 2024-02-29T09:52:58.490000+00:00 35986 Lock_to_C124 t_probe [us] = 1500, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 2343, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 390, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8483, LCminus [V] = 3.2740 60369.412311308 2024-02-29T09:53:43.697000+00:00 35987 SetAtt att_RCDAT : 12.0 dB 60369.412329097 2024-02-29T09:53:45.234000+00:00 35988 Lock_to_C124 t_probe [us] = 6000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 2052, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 342, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8483, LCminus [V] = 3.2740 60369.413139317 2024-02-29T09:54:55.237000+00:00 35989 SetAtt att_RCDAT : 15.0 dB 60369.413156806 2024-02-29T09:54:56.748000+00:00 35990 Lock_to_C124 t_probe [us] = 12000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1764, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 294, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8483, LCminus [V] = 3.2740 60369.414273102 2024-02-29T09:56:33.196000+00:00 35991 SetAtt att_RCDAT : 19.0 dB 60369.414290857 2024-02-29T09:56:34.730000+00:00 35992 Lock_to_C124 t_probe [us] = 30000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1239, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8483, LCminus [V] = 3.2740 60369.502902998 2024-02-29T12:04:10.819000+00:00 35993 SetAtt att_RCDAT : 22.0 dB 60369.502920914 2024-02-29T12:04:12.367000+00:00 35994 Lock_to_C124 t_probe [us] = 60000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 828, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 138, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8483, LCminus [V] = 3.2740 60369.538641169 2024-02-29T12:55:38.597000+00:00 36000 switchBeam Beam: B 60369.538691944 2024-02-29T12:55:42.984000+00:00 36001 MeasureFluorescenceLevels Bright : 31.2 +- 5.7, Dark : 0.1 +- 0.5, Threshold: int( ceil( 2.1 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60369.539245521 2024-02-29T12:56:30.813000+00:00 36002 Lock_to_C124 t_probe [us] = 60000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 828, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 138, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8483, LCminus [V] = 3.2740 60369.630120636 2024-02-29T15:07:22.423000+00:00 36003 SetAtt att_RCDAT : 24.0 dB 60369.630138727 2024-02-29T15:07:23.986000+00:00 36004 Lock_to_C124 t_probe [us] = 95000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 597, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 99, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8483, LCminus [V] = 3.2740 # End of file 60369_artiq_log.txt