# Start of file 60363_artiq_log.txt # First point: 60363.250745 2024-02-23T06:01:04.358000+00:00 # Last point: 60363.658682 2024-02-23T15:48:30.124000+00:00 # Num rows: 128 # File updated: 2024-02-24T01:10:45.617751 # Columns: MJD DATE RID PROGRAM MESSAGE 60363.250744884 2024-02-23T06:01:04.358000+00:00 35562 SetAtt att_RCDAT : 22.0 dB 60363.250771725 2024-02-23T06:01:06.677000+00:00 35563 Lock_to_C124 t_probe [us] = 60000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 828, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 138, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.258580092 2024-02-23T06:12:21.320000+00:00 35564 SetAtt att_RCDAT : 23.0 dB 60363.258597616 2024-02-23T06:12:22.834000+00:00 35565 Lock_to_C124 t_probe [us] = 76000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 702, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 117, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.344402199 2024-02-23T08:15:56.350000+00:00 35567 MeasureFluorescenceLevels Bright : 2.6 +- 1.5, Dark : 2.1 +- 1.2, Threshold: int( ceil( 2.4 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60363.344440405 2024-02-23T08:15:59.651000+00:00 35568 switchBeam Beam: ABC 60363.344543021 2024-02-23T08:16:08.517000+00:00 35569 MeasureFluorescenceLevels Bright : 2.5 +- 1.5, Dark : 2.4 +- 1.6, Threshold: int( ceil( 2.5 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60363.344900555 2024-02-23T08:16:39.408000+00:00 35573 MeasureFluorescenceLevels Bright : 159.4 +- 59.9, Dark : 131.5 +- 11.1, Threshold: int( ceil( 144.8 ) ) = 145, N_meas = 100, t_gate = 5.0 ms 60363.345161065 2024-02-23T08:17:01.916000+00:00 35576 MeasureFluorescenceLevels Bright : 91.0 +- 9.6, Dark : 3.3 +- 1.9, Threshold: int( ceil( 17.4 ) ) = 18, N_meas = 100, t_gate = 5.0 ms 60363.345230463 2024-02-23T08:17:07.912000+00:00 35577 switchBeam Beam: B 60363.345270509 2024-02-23T08:17:11.372000+00:00 35578 MeasureFluorescenceLevels Bright : 35.6 +- 6.3, Dark : 0.2 +- 0.4, Threshold: int( ceil( 2.7 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60363.345593403 2024-02-23T08:17:39.270000+00:00 35579 MicroMotionMeasurement Beam: A, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 15.378 60363.345806886 2024-02-23T08:17:57.715000+00:00 35580 MicroMotionMeasurement Beam: B, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 18.432 60363.345940671 2024-02-23T08:18:09.274000+00:00 35581 MicroMotionMeasurement Beam: C, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 11.546 60363.346409908 2024-02-23T08:18:49.816000+00:00 35582 switchBeam Beam: B 60363.346506574 2024-02-23T08:18:58.168000+00:00 35584 MeasureFluorescenceLevels Bright : 98.2 +- 9.9, Dark : 3.8 +- 1.7, Threshold: int( ceil( 19.3 ) ) = 20, N_meas = 100, t_gate = 5.0 ms 60363.346633819 2024-02-23T08:19:09.162000+00:00 35586 MeasureFluorescenceLevels Bright : 84.6 +- 9.8, Dark : 0.9 +- 1.0, Threshold: int( ceil( 8.8 ) ) = 9, N_meas = 100, t_gate = 5.0 ms 60363.346707292 2024-02-23T08:19:15.510000+00:00 35587 switchBeam Beam: A 60363.346789514 2024-02-23T08:19:22.614000+00:00 35588 MeasureFluorescenceLevels Bright : 41.2 +- 6.7, Dark : 3.1 +- 1.7, Threshold: int( ceil( 11.3 ) ) = 12, N_meas = 100, t_gate = 5.0 ms 60363.346962095 2024-02-23T08:19:37.525000+00:00 35590 MeasureFluorescenceLevels Bright : 0.1 +- 0.3, Dark : 0.1 +- 0.3, Threshold: int( ceil( 0.1 ) ) = 1, N_meas = 100, t_gate = 5.0 ms 60363.347018704 2024-02-23T08:19:42.416000+00:00 35591 MeasureFluorescenceLevels Bright : 0.1 +- 0.2, Dark : 0.1 +- 0.2, Threshold: int( ceil( 0.1 ) ) = 1, N_meas = 100, t_gate = 5.0 ms 60363.347098657 2024-02-23T08:19:49.324000+00:00 35592 switchBeam Beam: B 60363.347165174 2024-02-23T08:19:55.071000+00:00 35593 MeasureFluorescenceLevels Bright : 85.2 +- 9.6, Dark : 0.8 +- 1.1, Threshold: int( ceil( 8.2 ) ) = 9, N_meas = 100, t_gate = 5.0 ms 60363.347232500 2024-02-23T08:20:00.888000+00:00 35594 switchBeam Beam: A 60363.347274676 2024-02-23T08:20:04.532000+00:00 35595 MeasureFluorescenceLevels Bright : 58.5 +- 7.7, Dark : 4.3 +- 2.2, Threshold: int( ceil( 15.9 ) ) = 16, N_meas = 100, t_gate = 5.0 ms 60363.347501621 2024-02-23T08:20:24.140000+00:00 35597 MeasureFluorescenceLevels Bright : 0.1 +- 0.3, Dark : 0.0 +- 0.0, Threshold: int( ceil( 0.0 ) ) = 0, N_meas = 100, t_gate = 5.0 ms 60363.347576539 2024-02-23T08:20:30.613000+00:00 35598 switchBeam Beam: B 60363.347617963 2024-02-23T08:20:34.192000+00:00 35599 MeasureFluorescenceLevels Bright : 86.4 +- 9.3, Dark : 0.8 +- 0.9, Threshold: int( ceil( 8.1 ) ) = 9, N_meas = 100, t_gate = 5.0 ms 60363.368487488 2024-02-23T08:50:37.319000+00:00 35600 switchBeam Beam: A 60363.369699305 2024-02-23T08:52:22.020000+00:00 35602 MeasureFluorescenceLevels Bright : 94.9 +- 11.2, Dark : 7.5 +- 2.7, Threshold: int( ceil( 26.7 ) ) = 27, N_meas = 100, t_gate = 5.0 ms 60363.369971794 2024-02-23T08:52:45.563000+00:00 35604 MeasureFluorescenceLevels Bright : 0.1 +- 0.4, Dark : 0.0 +- 0.0, Threshold: int( ceil( 0.0 ) ) = 0, N_meas = 100, t_gate = 5.0 ms 60363.370114930 2024-02-23T08:52:57.930000+00:00 35606 MeasureFluorescenceLevels Bright : 151.1 +- 11.0, Dark : 17.9 +- 3.9, Threshold: int( ceil( 51.9 ) ) = 52, N_meas = 100, t_gate = 5.0 ms 60363.370161239 2024-02-23T08:53:01.931000+00:00 35607 switchBeam Beam: B 60363.370316077 2024-02-23T08:53:15.309000+00:00 35608 MeasureFluorescenceLevels Bright : 85.1 +- 9.0, Dark : 0.8 +- 0.9, Threshold: int( ceil( 8.3 ) ) = 9, N_meas = 100, t_gate = 5.0 ms 60363.370442153 2024-02-23T08:53:26.202000+00:00 35610 MeasureFluorescenceLevels Bright : 106.1 +- 11.8, Dark : 1.2 +- 1.1, Threshold: int( ceil( 11.1 ) ) = 12, N_meas = 100, t_gate = 5.0 ms 60363.370585938 2024-02-23T08:53:38.625000+00:00 35612 MeasureFluorescenceLevels Bright : 121.6 +- 12.6, Dark : 1.4 +- 1.1, Threshold: int( ceil( 12.9 ) ) = 13, N_meas = 100, t_gate = 5.0 ms 60363.370854062 2024-02-23T08:54:01.791000+00:00 35613 MicroMotionMinimizer N_photons: 100000, Initial (V12cm, V12diff, V34cm, V34diff) [V]: (-6.084000, 0.239600, 18.382000, 80.861100)num_iterations: 20, simplex_size [V]: 0.200, 60363.380168032 2024-02-23T09:07:26.518000+00:00 35614 MicroMotionMeasurement Beam: A, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 6.695 60363.380264306 2024-02-23T09:07:34.836000+00:00 35615 MicroMotionMeasurement Beam: B, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 8.306 60363.380348252 2024-02-23T09:07:42.089000+00:00 35616 MicroMotionMeasurement Beam: C, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 7.239 60363.380639294 2024-02-23T09:08:07.235000+00:00 35617 switchBeam Beam: B 60363.380800741 2024-02-23T09:08:21.184000+00:00 35619 MeasureFluorescenceLevels Bright : 48.7 +- 7.1, Dark : 0.3 +- 0.5, Threshold: int( ceil( 3.9 ) ) = 4, N_meas = 100, t_gate = 5.0 ms 60363.380996192 2024-02-23T09:08:38.071000+00:00 35621 switchBeam Beam: A 60363.381065787 2024-02-23T09:08:44.084000+00:00 35622 MeasureFluorescenceLevels Bright : 49.6 +- 7.4, Dark : 3.4 +- 1.7, Threshold: int( ceil( 12.9 ) ) = 13, N_meas = 100, t_gate = 5.0 ms 60363.381131748 2024-02-23T09:08:49.783000+00:00 35623 switchBeam Beam: B 60363.381340093 2024-02-23T09:09:07.784000+00:00 35624 MicroMotionMeasurement Beam: A, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 13.330 60363.381503345 2024-02-23T09:09:21.889000+00:00 35625 MicroMotionMeasurement Beam: B, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 14.093 60363.381618113 2024-02-23T09:09:31.805000+00:00 35626 MicroMotionMeasurement Beam: C, N_photons: 100000, N_bins: 25, f_mod [MHz]: 14.424000, duration [s]: 9.903 60363.381743067 2024-02-23T09:09:42.601000+00:00 35627 switchBeam Beam: B 60363.382396389 2024-02-23T09:10:39.048000+00:00 35628 Lock_to_C124 t_probe [us] = 76000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 702, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 117, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.391595069 2024-02-23T09:23:53.814000+00:00 35629 SetAtt att_RCDAT : 13.0 dB 60363.391612685 2024-02-23T09:23:55.336000+00:00 35630 Lock_to_C124 t_probe [us] = 7600, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1968, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 328, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.392126771 2024-02-23T09:24:39.753000+00:00 35631 SetAtt att_RCDAT : 3.0 dB 60363.392144768 2024-02-23T09:24:41.308000+00:00 35632 Lock_to_C124 t_probe [us] = 760, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 2397, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 399, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.393162431 2024-02-23T09:26:09.234000+00:00 35633 SetLockFreqs Linecenter [MHz AOM]: 75.559166, abs(B) [uT]: 4.765000000, EQS C1, C2, C4 [Hz]: 0.0, 0.0, 0.0 60363.393181354 2024-02-23T09:26:10.869000+00:00 35634 Lock_to_C124 t_probe [us] = 760, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 2397, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 399, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.393785636 2024-02-23T09:27:03.079000+00:00 35635 SetAtt att_RCDAT : 13.0 dB 60363.393805393 2024-02-23T09:27:04.786000+00:00 35636 Lock_to_C124 t_probe [us] = 7600, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1968, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 328, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.394388229 2024-02-23T09:27:55.143000+00:00 35637 SetLockFreqs Linecenter [MHz AOM]: 75.559166, abs(B) [uT]: 4.866000000, EQS C1, C2, C4 [Hz]: 0.0, 0.0, 0.0 60363.394406146 2024-02-23T09:27:56.691000+00:00 35638 Lock_to_C124 t_probe [us] = 7600, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1968, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 328, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.396200845 2024-02-23T09:30:31.753000+00:00 35639 SetAtt att_RCDAT : 16.0 dB 60363.396219120 2024-02-23T09:30:33.332000+00:00 35640 Lock_to_C124 t_probe [us] = 15000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1647, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 274, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.397359641 2024-02-23T09:32:11.873000+00:00 35641 SetAtt att_RCDAT : 19.0 dB 60363.397378599 2024-02-23T09:32:13.511000+00:00 35642 Lock_to_C124 t_probe [us] = 30000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1239, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.398834676 2024-02-23T09:34:19.316000+00:00 35643 SetAtt att_RCDAT : 22.0 dB 60363.398852824 2024-02-23T09:34:20.884000+00:00 35644 Lock_to_C124 t_probe [us] = 60000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 828, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 138, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.516521158 2024-02-23T12:23:47.428000+00:00 35646 SetAtt att_RCDAT : 22.0 dB 60363.516547951 2024-02-23T12:23:49.743000+00:00 35647 Lock_to_C124 t_probe [us] = 60000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 828, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 138, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.596477997 2024-02-23T14:18:55.699000+00:00 35648 SetAtt att_RCDAT : 12.0 dB 60363.596495845 2024-02-23T14:18:57.241000+00:00 35649 Lock_to_C124 t_probe [us] = 6000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 2052, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 342, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.597531574 2024-02-23T14:20:26.728000+00:00 35650 SetLockFreqs Linecenter [MHz AOM]: 75.559162, abs(B) [uT]: 4.889000000, EQS C1, C2, C4 [Hz]: 0.0, 0.0, 0.0 60363.597550058 2024-02-23T14:20:28.325000+00:00 35651 Lock_to_C124 t_probe [us] = 6000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 2052, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 342, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.597981470 2024-02-23T14:21:05.599000+00:00 35652 SetAtt att_RCDAT : 19.0 dB 60363.597999468 2024-02-23T14:21:07.154000+00:00 35653 Lock_to_C124 t_probe [us] = 30000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1239, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.604178981 2024-02-23T14:30:01.064000+00:00 35655 Lock_to_C124 t_probe [us] = 30000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1239, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.605580671 2024-02-23T14:32:02.170000+00:00 35656 SetAtt att_RCDAT : 12.0 dB 60363.605598148 2024-02-23T14:32:03.680000+00:00 35657 Lock_to_C124 t_probe [us] = 6000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 2052, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 342, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.606201227 2024-02-23T14:32:55.786000+00:00 35658 SetAtt att_RCDAT : 15.0 dB 60363.606219734 2024-02-23T14:32:57.385000+00:00 35659 Lock_to_C124 t_probe [us] = 12000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1764, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 294, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.606819583 2024-02-23T14:33:49.212000+00:00 35660 SetAtt att_RCDAT : 19.0 dB 60363.606839456 2024-02-23T14:33:50.929000+00:00 35661 Lock_to_C124 t_probe [us] = 30000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1239, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8480, LCminus [V] = 3.2660 60363.610791979 2024-02-23T14:39:32.427000+00:00 35663 switchBeam Beam: A 60363.614128611 2024-02-23T14:44:20.712000+00:00 35664 ScanLCFit LCplus start [V]: 1.700, LCplus stop [V]: 2.100, num_points: 100, LCminus start [V]: 2.600, LCminus stop [V]: 4.500, num_points: 100, t_gate [ms]: 1000, 60363.614144873 2024-02-23T14:44:22.117000+00:00 35665 switchBeam Beam: B 60363.614552373 2024-02-23T14:44:57.325000+00:00 35666 Lock_to_C124 t_probe [us] = 30000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1239, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8539, LCminus [V] = 3.2892 60363.616380914 2024-02-23T14:47:35.311000+00:00 35667 SetAtt att_RCDAT : 12.0 dB 60363.616399016 2024-02-23T14:47:36.875000+00:00 35668 Lock_to_C124 t_probe [us] = 6000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 2052, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 342, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8539, LCminus [V] = 3.2892 60363.616828240 2024-02-23T14:48:13.960000+00:00 35669 SetAtt att_RCDAT : 15.0 dB 60363.616848044 2024-02-23T14:48:15.671000+00:00 35670 Lock_to_C124 t_probe [us] = 12000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1764, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 294, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8539, LCminus [V] = 3.2892 60363.617261794 2024-02-23T14:48:51.419000+00:00 35671 SetAtt att_RCDAT : 19.0 dB 60363.617279190 2024-02-23T14:48:52.922000+00:00 35672 Lock_to_C124 t_probe [us] = 30000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1239, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8539, LCminus [V] = 3.2892 60363.618710359 2024-02-23T14:50:56.575000+00:00 35673 SetAtt att_RCDAT : 22.0 dB 60363.618727870 2024-02-23T14:50:58.088000+00:00 35674 Lock_to_C124 t_probe [us] = 60000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 828, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 138, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8539, LCminus [V] = 3.2892 60363.633681158 2024-02-23T15:12:30.052000+00:00 35675 SetAtt att_RCDAT : 12.0 dB 60363.633699421 2024-02-23T15:12:31.630000+00:00 35676 Lock_to_C124 t_probe [us] = 6000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 2052, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 342, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8539, LCminus [V] = 3.2892 60363.634453194 2024-02-23T15:13:36.756000+00:00 35677 SetAtt att_RCDAT : 15.0 dB 60363.634471077 2024-02-23T15:13:38.301000+00:00 35678 Lock_to_C124 t_probe [us] = 12000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1764, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 294, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8539, LCminus [V] = 3.2892 60363.634906435 2024-02-23T15:14:15.916000+00:00 35679 SetAtt att_RCDAT : 19.0 dB 60363.634925463 2024-02-23T15:14:17.560000+00:00 35680 Lock_to_C124 t_probe [us] = 30000, n_shots = 2, g1 = 0.4, T_drift_s = 600.0, N_drift = 1239, pmt_thr = 7, T_p0avg_s = 300.0, N_p0avg = 206, (C1, C2, C4) att [dB] = (15.0, 16.0, 16.0), LCplus [V] = 1.8539, LCminus [V] = 3.2892 60363.643460521 2024-02-23T15:26:34.989000+00:00 35682 MeasureFluorescenceLevels Bright : 0.4 +- 0.6, Dark : 0.3 +- 0.6, Threshold: int( ceil( 0.3 ) ) = 1, N_meas = 100, t_gate = 5.0 ms 60363.643520914 2024-02-23T15:26:40.207000+00:00 35683 switchBeam Beam: ABC 60363.643575081 2024-02-23T15:26:44.887000+00:00 35684 MeasureFluorescenceLevels Bright : 2.4 +- 1.4, Dark : 2.5 +- 1.6, Threshold: int( ceil( 2.4 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60363.643827789 2024-02-23T15:27:06.721000+00:00 35686 MeasureFluorescenceLevels Bright : 91.9 +- 9.9, Dark : 91.3 +- 10.8, Threshold: int( ceil( 91.6 ) ) = 92, N_meas = 100, t_gate = 5.0 ms 60363.644332916 2024-02-23T15:27:50.364000+00:00 35687 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 1000.0 60363.644416065 2024-02-23T15:27:57.548000+00:00 35689 switchBeam Beam: B 60363.644469086 2024-02-23T15:28:02.129000+00:00 35690 MeasureFluorescenceLevels Bright : 0.4 +- 0.6, Dark : 0.5 +- 1.2, Threshold: int( ceil( 0.5 ) ) = 1, N_meas = 100, t_gate = 5.0 ms 60363.644541146 2024-02-23T15:28:08.355000+00:00 35691 MeasureFluorescenceLevels Bright : 0.4 +- 0.6, Dark : 0.5 +- 0.6, Threshold: int( ceil( 0.5 ) ) = 1, N_meas = 100, t_gate = 5.0 ms 60363.644601435 2024-02-23T15:28:13.564000+00:00 35692 switchBeam Beam: ABC 60363.644645301 2024-02-23T15:28:17.354000+00:00 35693 MeasureFluorescenceLevels Bright : 2.4 +- 1.6, Dark : 2.4 +- 1.4, Threshold: int( ceil( 2.4 ) ) = 3, N_meas = 100, t_gate = 5.0 ms 60363.645083079 2024-02-23T15:28:55.178000+00:00 35694 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 1000.0 60363.645398078 2024-02-23T15:29:22.394000+00:00 35696 MeasureFluorescenceLevels Bright : 3.9 +- 2.1, Dark : 3.7 +- 1.8, Threshold: int( ceil( 3.8 ) ) = 4, N_meas = 100, t_gate = 5.0 ms 60363.645919723 2024-02-23T15:30:07.464000+00:00 35697 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 1000.0 60363.646167604 2024-02-23T15:30:28.881000+00:00 35698 MeasureFluorescenceLevels Bright : 3.9 +- 2.0, Dark : 3.7 +- 1.9, Threshold: int( ceil( 3.8 ) ) = 4, N_meas = 100, t_gate = 5.0 ms 60363.646499908 2024-02-23T15:30:57.592000+00:00 35700 MeasureFluorescenceLevels Bright : 142.0 +- 11.9, Dark : 142.3 +- 12.9, Threshold: int( ceil( 142.1 ) ) = 143, N_meas = 100, t_gate = 5.0 ms 60363.646979838 2024-02-23T15:31:39.058000+00:00 35701 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 1000.0 60363.647097963 2024-02-23T15:31:49.264000+00:00 35702 MeasureFluorescenceLevels Bright : 140.2 +- 12.0, Dark : 138.7 +- 10.9, Threshold: int( ceil( 139.5 ) ) = 140, N_meas = 100, t_gate = 5.0 ms 60363.647451007 2024-02-23T15:32:19.767000+00:00 35703 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 100.0 60363.647664190 2024-02-23T15:32:38.186000+00:00 35704 MeasureFluorescenceLevels Bright : 142.4 +- 12.0, Dark : 139.5 +- 11.2, Threshold: int( ceil( 141.0 ) ) = 141, N_meas = 100, t_gate = 5.0 ms 60363.647875092 2024-02-23T15:32:56.408000+00:00 35705 MeasureFluorescenceLevels Bright : 141.4 +- 12.5, Dark : 138.9 +- 10.9, Threshold: int( ceil( 140.2 ) ) = 141, N_meas = 100, t_gate = 5.0 ms 60363.648106643 2024-02-23T15:33:16.414000+00:00 35706 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 100.0 60363.648195417 2024-02-23T15:33:24.084000+00:00 35707 MeasureFluorescenceLevels Bright : 139.8 +- 11.3, Dark : 138.9 +- 10.2, Threshold: int( ceil( 139.4 ) ) = 140, N_meas = 100, t_gate = 5.0 ms 60363.648444572 2024-02-23T15:33:45.611000+00:00 35709 MeasureFluorescenceLevels Bright : 20.0 +- 4.6, Dark : 20.1 +- 4.9, Threshold: int( ceil( 20.0 ) ) = 21, N_meas = 100, t_gate = 5.0 ms 60363.648730775 2024-02-23T15:34:10.339000+00:00 35710 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 100.0 60363.648972882 2024-02-23T15:34:31.257000+00:00 35711 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 100.0 60363.649050348 2024-02-23T15:34:37.950000+00:00 35712 MeasureFluorescenceLevels Bright : 19.5 +- 4.2, Dark : 21.5 +- 4.5, Threshold: int( ceil( 20.4 ) ) = 21, N_meas = 100, t_gate = 5.0 ms 60363.649349410 2024-02-23T15:35:03.789000+00:00 35715 MeasureFluorescenceLevels Bright : 21.0 +- 4.6, Dark : 19.6 +- 4.5, Threshold: int( ceil( 20.3 ) ) = 21, N_meas = 100, t_gate = 5.0 ms 60363.649635359 2024-02-23T15:35:28.495000+00:00 35716 MeasureFluorescenceLevels Bright : 21.2 +- 5.0, Dark : 20.6 +- 5.7, Threshold: int( ceil( 20.9 ) ) = 21, N_meas = 100, t_gate = 5.0 ms 60363.658681991 2024-02-23T15:48:30.124000+00:00 35717 CoolingDetuningScan From [AOM MHz]: 175.000, To [AOM MHz]: 215.000, num_pts: 20, t_gate (ms) = 100.0 # End of file 60363_artiq_log.txt